background image

M2PRU

P.  / 3

EM-5076 Rev.4

PULSE SCALER

(selectable range)

MODEL

M2PRU

INSTRUCTION MANUAL

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If  you  have  any  problems  or  questions  with  the  product, 
please contact M-System’s Sales Office or representatives.

 PACKAGE INCLUDES:

  Signal conditioner (body + base socket) ...................... (1)

 MODEL NO.

Confirm  Model  No.  marking  on  the  product  to  be  exactly 
what you ordered.

 INSTRUCTION MANUAL

This  manual  describes  necessary  points  of  caution  when 
you use this product, including installation, connection and 
basic maintenance procedures.

POINTS OF CAUTION

 NONINCENDIVE APPROVAL OPTION

• This equipment is suitable for use in Class I, Div. 2, Groups 

A, B, C and D or Non-Hazardous Locations only.

• WARNING! Before You  Remove  the  Unit  from  Its  Base 

Socket or Mount It, Turn Off the Power Supply and Input 
Signal for Safety.

• WARNING! – Explosion Hazard –
  Substitution  of  Components  May  Impair  Suitability  for 

Class I, Div. 2.

• WARNING! – Explosion Hazard –
  Do  Not  Disconnect  Equipment  Unless  Power  Has  Been 

Switched Off or The Area is Known To Be Non-Hazardous.

• The equipment was evaluated for use in the ambient tem-

perature  and  relative  humidity  as  mentioned  in ‘ENVI-
RONMENT’ section.

• The input and output wiring must be in accordance with 

Class I, Div. 2 wiring methods and in accordance with the 
authority having jurisdiction for use in these hazardous 
locations.

 CONFORMITY WITH EC DIRECTIVES OR UL

• This equipment is suitable for use in a Pollution Degree 

2 environment and in Installation Category II, with the 
maximum operating voltage of 300V.

  Insulation between signal input and output for the open 

collector or voltage pulse output is appropriate for basic 
insulation class.  Prior to installation, check that the in-
sulation  class  of  this  unit  satisfies  the  system  require-
ments.

• Altitude up to 2000 meters
• The equipment must be mounted inside a panel.
• The  equipment  must  be  installed  such  that  appropriate 

clearance and creepage distances are maintained to con-
form to CE/UL requirements.  Failure to observe these re-
quirements may invalidate the CE/UL conformance.

 POWER INPUT RATING & OPERATIONAL RANGE

Locate the power input rating marked on the product and 
confirm its operational range as indicated below:
  100 – 240V AC rating: 85 – 264V (90 – 264V for UL), 
     

47 – 66 Hz, approx. 4 – 6VA

  24V DC rating: 24V ±10%, approx. 3W
  11 – 27V DC rating: 11 – 27V, approx. 3W
  110V DC rating: 85 – 150V (110V ±10% for UL), approx. 3W

 GENERAL PRECAUTIONS

Before you remove the unit from its base socket or mount it, 
turn off the power supply and input signal for safety.

 ENVIRONMENT

• Indoor use
• When heavy dust or metal particles are present in the air, 

install the unit inside proper housing with sufficient ven-
tilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -5 to +55°C     

(23 to 131°F) with relative humidity within 30 to 90% RH 
in order to ensure adequate life span and operation.

• Be sure that the ventilation slits are not covered with ca-

bles, etc.

 WIRING

• Do  not  install  cables  (power  supply,  input  and  output) 

close  to  noise  sources  (relay  drive  cable,  high  frequency 
line, etc.).

• Do  not  bind  these  cables  together  with  those  in  which 

noises are present.  Do not install them in the same duct.

 AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying  complete  performance  described  in  the  data 
sheet.

• With  voltage  output,  do  not  leave  the  output  terminals 

shortcircuited for a long time.  The unit is designed to en-
dure it without breakdown, however, it may shorten ap-
propriate life duration.

 FILTER

The M2PRU is designed to accept at the maximum of 100 
kHz, which may cause errors due to chattering in the input 
pulses.
  A filter circuitry (time constant: approx. 1 msec.) is incor-

porated to eliminate unwanted chattering when the me-
chanical contact input is specified.  It is effective for most 
relay types, however, an external CR filter as indicated be-
low, could be added if the user need improvement.  Limit 
the input frequency to 10 Hz at maximum.

Relay

R

C

PULSE

SCALER

C = 100 µF
R = 100

Rugghölzli 2
CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

[email protected]

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Summary of Contents for M2PRU

Page 1: ...z 90 264 V for UL DC Power R 24 V DC Operational voltage range 24 V 10 ripple 10 p p max R2 11 27 V DC Operational voltage range 11 27 V ripple 10 p p max Select N for Standards Approvals code P 110 V...

Page 2: ...shortcircuit Open Collector Frequency range 0 100 kHz Pulse width time requirement Min 5 sec for ON and OFF Sensing Approx 24 V DC 2 mA Detecting levels 400 0 8 V for ON 1200 2 4 V for OFF Mechanical...

Page 3: ...t Reinforced insulation Approval UL C UL nonincendive Class I Division 2 Groups A B C and D hazardous locations ANSI ISA 12 12 01 CAN CSA C22 2 No 213 UL C UL general safety requirements UL 61010B 1 C...

Page 4: ...or Input Connection Examples PWR Voltage Pulse DC Coupled PWR Open Collector Output Connection Examples 9 12 9 12 Voltage Pulse 9 12 AC DC SWITCH SCALING FACTOR ADJ Scaler PULSE WIDTH ADJ 12k 24V 1 4...

Page 5: ...o observe these re quirements may invalidate the CE UL conformance POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicat...

Page 6: ...in the diagram below or refer to the connection diagram on the side of the unit OUTPUT 9 12 U V POWER 13 14 INPUT 1 5 4 SENSOR EXCITATION Mechanical Contact Open Collector Input Connection Examples PW...

Page 7: ...switches 10 1 through 10 n apply respectively to each digit of the decimals and exponential as shown below Output Rate Input Rate 0 A B C D 10 E where the scaling factor is adjustable from 1 0000 10...

Reviews: