KEY OPERATION AND OPERATION IN ABNORMALITIES

1) Prior to operation, test alarm functions to confirm correct 

alarm mode setting.

2) When the input wires are broken, the unit displays LLLL.  

Be sure to turn off the power supply before replacing the 

sensor.

 

OTHERS

1) Do not use organic solvents such as alcohol or benzine to 

clean the unit.  Use a neutral detergent.

TERMINAL CONNECTIONS

Connect the unit as in the diagram below.

 

EXTERNAL DIMENSIONS  unit: mm (inch)

5

6

7

8

2

1

11

10

3

9

4

  [3.5] (.14) 

110 (4.33)

7.5

(.3)

48 (1.89)

48 (1.89)

t

1 ≤ t ≤ 8

(.04 ≤ t ≤.31)

MOUNTING

BRACKET

71.5 (2.81)

70 (2.76)

40 (1.57)

50 (1.97)

7.8 (.31)

CLAMP

(top & bottom)

DIN RAIL

35mm wide

2–4.5 (.18) dia.

MTG HOLE

25 (.98) deep

1 1–M3.5

SCREW

PACKING

7 (.28)

PANEL

1.5 (.06)

 

CONNECTION DIAGRAM

7

8

10

11

9

2

3

1

N.C.

N.O.

COM

SET1

N.C.

N.O.

COM

SET2

U(+)

V(–)

POWER

+

INPUT

5

6

 

PANEL CUTOUT  unit: mm

45

45

+0.5 

0    

+0.5  0    

85 MIN.

63 MIN.

INSTALLATION

Detach the yellow clamps located at the top and bottom of the unit for separate the body from the base socket.

 

DIN RAIL MOUNTING

Set the base socket so that its 
DIN rail adaptor is at the bot-
tom.  Position the upper hook 
at the rear side of base socket 
on the DIN rail and push in 
the lower.  When removing the 
socket, push down the DIN 
rail adaptor utilizing a minus 
screwdriver and pull.

 

WALL MOUNTING

Refer to “EXTERNAL DI-
MENSIONS.”

 

HOW TO MOUNT THE UNIT ON A PANEL

The watertight packing must be in place to hold the unit.  
Do not remove it.

1) Insert the unit into the panel cutout.
2) Push the mounting brackets into the grooves on both 

sides of the rear module, until they hit the panel’s rear 

side.

Mounting Bracket

Watertight packing

Panel

Clamp

(top & bottom)

DIN Rail

35mm wide

Spring Loaded

DIN Rail Adaptor

Shape and size of the base socket 
are slightly different with various 
socket types.

Summary of Contents for KS2V3

Page 1: ...re change or condensation Corrosive gases sulfide and ammonia in particular or flammable gases Vibration or mechanical shock Direct contact with water oil chemical materials steam or vapor Exposure to...

Page 2: ...CONNECTION DIAGRAM 7 8 10 11 9 2 3 1 N C N O COM SET1 N C N O COM SET2 U V POWER INPUT 5 6 PANEL CUTOUT unit mm 45 45 0 5 0 0 5 0 85 MIN 63 MIN INSTALLATION Detach the yellow clamps located at the to...

Page 3: ...ET2 is in tripped conditions PREPARING POWER UP When the power is turned on the unit displays all segments on the Measured Value PV Alarm Setpoint Value SET1 Display and on the Alarm Setpoint Value SE...

Page 4: ...T1 P d2 1 Seconds 1 to 999 Switching delay timer for SET2 3 5 P dF 5 0 Seconds 0 0 to 900 0 Time constant for the input filter ADJ0 0 0 Deviative engineering unit 6 50 to 50 FS User s ZERO adjustment...

Page 5: ...Pat tern 2 Pattern 3 Upper blank Lower ST1 DOWN Press the key once Next parameter name is displayed Upper black Lower ST2 SEL Press the key once ST2 is replaced with current setting Upper blank Lower...

Page 6: ...atus or Operation Display Current display PTn 2 in this example Display pattern 2 Upper PV Lower blank SEL Keep pressing the key for 7 seconds Maintain while the display indicates Pat tern 2 Pattern 3...

Page 7: ...for 3 sec Upper blank Lower 6 SEL Press the key once The lower display indicates the param eter name P A2 again Upper blank Lower P A2 SEL Keep pressing the key for 3 seconds Maintain while the displ...

Page 8: ...ame ADJ0 again Upper blank Lower ADJ0 SEL Keep pressing the key for 3 seconds Maintain while the display changes Display pattern 1 Upper ST1 setpoint Lower ST2 setpoint User s SPAN adjustment Example...

Page 9: ...Low alarm With the function the unit is NOT tripped until the input goes once above and then below the setpoint ERROR MESSAGES DISPLAY ERROR DESCRIPTION WHAT TO DO UUUU The input exceeds 105 Return th...

Reviews: