NORMAL OPERATION (RUN) MODE

ERROR MODE

System Error
Indicates the CPU’s communication error.

DIP SW Error
DIP SW configuration is inappropriate.
Check the DIP SW setting referring to Tables 2 – 6.

PC Configuration RUN Mode (Option A)
The transmitter is configured via PC and 
is in normal operating conditions.

DIP SW Configuration RUN Mode
The transmitter is configured via DIP SW and 
is in normal operating conditions.

Output Saturated in PC Configuration Mode 
(Option A)
The output is saturated.
(approximately below -15% or above +115%)

Output Saturated in DIP SW Configuration Mode
The output is saturated.
(approximately below -15% or above +115%)

Amber LED

Green LED

Red LED

OFF

ON

Blink

A

G

R

STATUS INDICATOR LED

Combinations of the three front LEDs (LD1, LD2, LD3) in-
dicate the transmitter’s operating status by different blink-
ing patterns.
Examples are shown below.

Summary of Contents for Current Loop Supply M3LDY

Page 1: ...rs for the power source input and output connected to the unit COSEL Model NAC 04 472 TDK Model ZCAT 3035 1330 or equivalent is recommended Install lightning surge protectors for those wires connect e...

Page 2: ...NG Set the unit so that its DIN rail adaptor is at the bottom Position the upper hook at the rear side of the unit on the DIN rail and push in the lower When removing the unit push down the DIN rail a...

Page 3: ...ting no extra space is needed between units DIN RAIL 35mm wide EXTERNAL INTERNAL VIEWS 8 7 6 5 4 3 2 1 ON OFF ON OFF 4 3 2 1 Configuration DIP SW 10 11 12 7 8 9 4 5 6 1 2 3 Configurator Jack DOWN Butt...

Page 4: ...mable features can be set up on a PC regardless of other DIP SW setting except that the output type must be selected with the DIP SW1 1 through SW1 4 See Table 6 For detailed information on the PC con...

Page 5: ...ntrol Buttons Red LED OFF ON Blink RUN MODE LD2 LD3 A G RUN MODE LD2 LD3 G R LD1 LD2 LD3 LD1 LD2 LD3 0 INPUT CONFIGURED 100 INPUT CONFIGURED INPUT CALIBRATION MODE LD1 OUTPUT CALIBRATION MODE LD2 LD3...

Page 6: ...t level e g 1V Push DOWN button until the LD1 blinks for approx 2 sec and then turns OFF When you release the button the LD1 is returned to ON 7 100 Output Ranging Increase or decrease the simu lated...

Page 7: ...tion RUN Mode Option A The transmitter is configured via PC and is in normal operating conditions DIP SW Configuration RUN Mode The transmitter is configured via DIP SW and is in normal operating cond...

Reviews: