COMPONENT IDENTIFICATION

Body

SW Setting

Specifications
(side)

 HOW TO OPEN THE COVER WHEN SETTING DIP SW

Hold at the top and bottom of the unit as shown below and 

slide the housing cover gently to open until it hits the latch-
ing inside the unit.

• Housing Cover Fully Opened

Caution: 
Handle the cover carefully to protect internal components from damage.
DO NOT pull beyond where the housing cover is latched.  The plastic 
housing may be damaged.

  HOW TO SEPARATE THE EURO TYPE CONNECTOR 

TERMINAL BLOCKS

When you need to separate the euro type connector termi-
nal blocks from the transmitter body for wiring, insert a mi-
nus driver between the euro type connector terminal block 
and the housing body, pull up the driver and pull out the 
euro type connector terminal block.

INSTALLATION

 DIN RAIL MOUNTING

Set the unit so that its DIN rail adaptor is at the bottom.  
Position the upper hook at the rear side of the unit on the 
DIN rail and push in the lower.  When removing the unit, 
push down the DIN rail adaptor utilizing a minus screw-
driver and pull.

DIN Rail

35mm wide

Spring Loaded

DIN Rail Adaptor

TERMINAL CONNECTIONS

Connect the unit as in the diagram below or refer to the con-
nection diagram on the side of the unit.

+

+

4

CONFIGURATOR

JACK

7

8

11

12

OUTPUT

POWER

+

1

3

2

2-WIRE

TRANSMITTER

+

V

+

(1 – 5V DC)

MONITOR

■ 

When Used as Isolator

250Ω

No Connection

No Connection

2

1

24.9Ω

+

INPUT

4

3

 WIRING INSTRUCTIONS

  • Applicable wire size
   

Solid:  

0.2 to 2.5 mm

2

 (0.55 to 1.75 dia.)

   

Stranded:  0.2 to 2.5 mm

2

 

 

 

Tinning wire ends may cause contact failure   

 

 

and therefore is not recommended.

   

Ferruled:  0.2 to 1.5 mm

2

 (0.55 to 1.35 dia.)

 

 

 

 

The following Phoenix Contact terminals are  

   

 recommended:

 

 

 

 

AI 0,25-8YE 

0.2 to 0.25 mm

2

 

 

 

 

AI 0,34-8TQ 

0.25 to 0.34 mm

2

 

 

 

 

AI 0,5-8WH  

0.34 to 0.5 mm

2

 

 

 

 

AI 0,75-8GY 

0.5 to 0.75 mm

2

 

 

 

 

AI 1,0-8RD   

0.75 to 1.0 mm

2

 

 

 

 

AI 1,5-8BK   

1.0 to 1.5 mm

2

  • Expose wire conductors by 8 mm (0.31”).

8 mm

8 mm

4 mm dia.

max.

4 mm dia.

max.

Wire exposure

Recommended
ferruled wire

Summary of Contents for Current Loop Supply M3LDY

Page 1: ...rs for the power source input and output connected to the unit COSEL Model NAC 04 472 TDK Model ZCAT 3035 1330 or equivalent is recommended Install lightning surge protectors for those wires connect e...

Page 2: ...NG Set the unit so that its DIN rail adaptor is at the bottom Position the upper hook at the rear side of the unit on the DIN rail and push in the lower When removing the unit push down the DIN rail a...

Page 3: ...ting no extra space is needed between units DIN RAIL 35mm wide EXTERNAL INTERNAL VIEWS 8 7 6 5 4 3 2 1 ON OFF ON OFF 4 3 2 1 Configuration DIP SW 10 11 12 7 8 9 4 5 6 1 2 3 Configurator Jack DOWN Butt...

Page 4: ...mable features can be set up on a PC regardless of other DIP SW setting except that the output type must be selected with the DIP SW1 1 through SW1 4 See Table 6 For detailed information on the PC con...

Page 5: ...ntrol Buttons Red LED OFF ON Blink RUN MODE LD2 LD3 A G RUN MODE LD2 LD3 G R LD1 LD2 LD3 LD1 LD2 LD3 0 INPUT CONFIGURED 100 INPUT CONFIGURED INPUT CALIBRATION MODE LD1 OUTPUT CALIBRATION MODE LD2 LD3...

Page 6: ...t level e g 1V Push DOWN button until the LD1 blinks for approx 2 sec and then turns OFF When you release the button the LD1 is returned to ON 7 100 Output Ranging Increase or decrease the simu lated...

Page 7: ...tion RUN Mode Option A The transmitter is configured via PC and is in normal operating conditions DIP SW Configuration RUN Mode The transmitter is configured via DIP SW and is in normal operating cond...

Reviews: