background image

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

Angle sensor alarm (body + base socket) ...........................(1)

 

MODEL NO.

Confirm Model No. marking on the product to be exactly 
what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection, and 
basic maintenance procedures.

 

CONNECTING WITH ANGLE SENSOR

The unit must be adjusted in combination with the angle 
sensor that is actually used.  Adjust input while monitoring 
with a multimeter connected to the terminal 6.  Then, take 
appropriate measures for preventing short circuit.
For details, refer to the sections of “CALIBRATION” and 
“ADJUSTMENT PROCEDURE.”

POINTS OF CAUTION

 

POWER INPUT RATING & OPERATIONAL RANGE

• Locate the power input rating marked on the product and 

confirm its operational range as indicated below:

  

AC power

: Rating ±10%, 50/60 ±2 Hz, approx. 2VA

  

DC power

:  Rating ±10%, approx. 2W 

 

or 85 – 150V, approx. 2W for 110V rating

 

GENERAL PRECAUTIONS

• Before you remove the unit from its base socket or mount 

it, turn off the power supply and input signal for safety.

 

ENVIRONMENT

• Indoor use.
• When heavy dust or metal particles are present in the 

air, install the unit inside a proper housing with sufficient 
ventilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -5 to +60°C 

(23 to 140°F) with relative humidity within 30 to 90% RH 
in order to ensure adequate life span and operation.

 

WIRING

• Do not install cables close to noise sources (relay drive 

cable, high frequency line, etc.).

• Do not bind these cables together with those in which 

noises are present.  Do not install them in the same duct.

 

AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying complete performance described in the data 
sheet.

COMPONENT IDENTIFICATION

Body

Base Socket

Connection Diagram

Front Cover

Specifications

 

HOW TO OPEN THE FRONT COVER

Hang your finger on the hook at the top of the front cover 
and pull toward you.

The shape of base socket may be different
for some models. 

 

FRONT PANEL CONFIGURATIONS

Front Cover (open)

No.1 LED

No.1 Hysteresis (Deadband) Adj.

No.2 Hysteresis (Deadband) Adj.

No.2 LED

No.1 Setpoint Adj.

No.2 Setpoint Adj.

Zero Adj.

Span Adj.

Input Monitor

• Input Monitor
• Span Adj.
• Zero Adj.
• No. 1 Setpoint Adj.

Used for adjusting No. 1 alarm setpoint.

• No. 1 LED

Turns on when No. 1 alarm is tripped.

• No. 1 Deadband (hysteresis) Adj.

Used for adjusting No. 1 deadband (hysteresis) within 1 – 100%.

• No. 2 Deadband (hysteresis) Adj.

Used for adjusting No. 2 deadband (hysteresis) within 1 – 100%.

• No. 2 LED

Turns on when No. 2 alarm is tripped.

• No. 2 Setpoint Adj.

Used for adjusting No. 2 alarm setpoint.

ANGLE SENSOR ALARM

MODEL

ANR

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]