16
73VR31BLD USERS MANUAL EM-7397-C Rev.4
2.6 INPUT PEN SETTING (INDIVIDUAL)
Pressing Input Pen Setting (Individual) button under Setting buttons opens the window shown in Figure 2.6.
Figure 2.6: Input pen setting (Individual).
2.6.1 COMMON SETTING
Enable / Disable
Enable / Disable the recording. The pen’s input data is stored when this selection is set to Enable.
Analog / Discrete
Analog / Discrete signal. Select pen’s signal type. With 20 msec. storing interval, this selection is greyed out as the
signal allocation is fixed: Pens 1 through 8 for analog, Pens 9 through 16 for discrete.
Channel No.
Assign the R3 series modules’ channel No. to each pen. As the signal allocation is fixed as in the table below for 20
msec. storing interval, there is no need of setting Channel No.
Input Pen
Signal Type
73VR3100 Channel No.
1 through 8
Analog
1 through 8
9 through 16
Discrete
9 through 16
Tag
Enter a desired tag name.
Tag name
Max. 8 characters
Unit
Enter a desired unit name.
Unit
Max. 4 characters
Color
Touching the current selection of the Color opens a color palette. Choose a desired color from the palette.
Line thickness
This setting is selectable even during recording.
Normal
Normal line (1 pixel)
Thick
Thick line (3 pixels)