47LHZ

P. 11 / 14

EM-9517-B Rev.4

PARAMETER

Alarm points

Quad alarm: LL, L, H, HH

Dual alarm: L, H

INDICATORS

FUNCTION

DEFAULT

VALUE

DISPLAY

L

H

Fnc

L

H

HH

LL

Fnc

...

...
...

LL setpoint

LL deadband (hysteresis) 
LL ON delay time

LL: ON delay time (seconds)

LL: Deadband (hysteresis) value

LL: Setpoint value

LL

Fnc

LL trip action

LL: Hi trip

LL

Fnc

LL: Lo trip

LL coil at alarm

LL: Coil energized at alarm

LL

Fnc

LL: Coil de-energized at alarm

D/P

LL

Fnc

LL

P

Fnc

...

...
...

L setpoint

L deadband (hysteresis) 
L ON delay time

L: ON delay time (seconds)

L: Deadband (hysteresis) value

L: Setpoint value

L

Fnc

L trip action

L: Hi trip

L

Fnc

L: Lo trip

L coil at alarm

L: Coil energized at alarm

L

Fnc

L: Coil de-energized at alarm

D/P

L

Fnc

L

P

Fnc

...

...
...

H setpoint

H deadband (hysteresis) 
H ON delay time

H: ON delay time (seconds)

H: Deadband (hysteresis) value

H: Setpoint value

H

Fnc

H trip action

H: Hi trip

H

Fnc

H: Lo trip

H coil at alarm

H: Coil energized at alarm

H

Fnc

H: Coil de-energized at alarm

D/P

H

Fnc

H

P

Fnc

...

...
...

HH setpoint

HH deadband (hysteresis) 
HH ON delay time

HH: ON delay time (seconds)

HH: Deadband (hysteresis) value

HH: Setpoint value

HH

Fnc

HH trip action

HH: Hi trip

HH

Fnc

HH: Lo trip

HH coil at alarm

HH: Coil energized at alarm

HH

Fnc

HH: Coil de-energized at alarm

D/P

HH

Fnc

HH

P

Fnc

Note 1: Alarm Setting Mode is locked with no-alarm-output type.
 

Alarm points depend upon the model suffix code.  LL and HH setpoints are usable only for quad alarm type.

Note 2: LED status:           = ON,          = Blinking
Note 3: Specify setpoint and deadband in the scaled range values.  Alarm is disabled when ‘ – – – – ’ is specified for the setpoint.
Note 4: All alarm setpoints are disabled (reset to ‘ – – – – ’ status) when the input type has been changed.  Re-setting is required.
Note 5: Decimal point is not indicated when setting deadband values.

Main display flashing 
at alarm

Flashing in 1.0 sec. intervals

No flashing

Fnc

Flashing in 0.1 sec. intervals

Flashing in 0.2 sec. intervals

Flashing in 0.5 sec. intervals

Summary of Contents for 47LHZ

Page 1: ...3 and properly indicate it POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below 100 240V AC rating 85 264V 50...

Page 2: ...is tripped H turns on when the H alarm is tripped HH turns on when the HH alarm is tripped P turns on when none of the other alarms is tripped 3 Function indicators Indicate setting modes and status...

Page 3: ...ng must be in place to hold the meter Do not remove it 1 Insert the unit into the panel cutout 2 Push the mounting brackets into the grooves on both sides of the rear module until they hit the panel s...

Page 4: ...18 19 Lc LLc LLa La Hc HHc Ha HHa LL OUTPUT L OUTPUT H OUTPUT L OUTPUT H OUTPUT HH OUTPUT 9 10 POWER U V ALARM SUFFIX CODE 2 SPDT contact 2 points 9 10 POWER U V ALARM SUFFIX CODE 0 No alarm output 7...

Page 5: ...out Setting Mode Go through the lockout settings Measuring Mode Hold down Alarm or Scale button for 1 second Hold down Scale button for 3 seconds Measuring Measuring stopped 3 Mode transition 1 Preset...

Page 6: ...le button shifts one to the previous Changing parameters Pressing Shift button while one of the parameter settings is indicated on the display shifts the panel meter into the setting standby mode The...

Page 7: ...n Scale button for 3 seconds Hold down Alarm or Scale button for 1 second Shift Shift Alarm Scale Alarm Alarm Scale Alarm Alarm Scale Alarm Scale Alarm Shift Shift Alarm Scale Alarm Scaling Setting Mo...

Page 8: ...range 5 to 105 increasing decreasing increasing decreasing Fnc Analog output 100 adjustment Analog output 100 adjustment adjustable range 5 to 105 Scaling setting Go through the scaling setting in the...

Page 9: ...larm Setting Mode Alarm Shift L Setpoint L Deadband L ON Delay Time 19999 19999 0000 9999 00 99 Shift Shift Alarm Alarm Alarm Alarm Alarm Alarm L Coil at Alarm RYEN RYDN Shift Alarm Alarm Shift L Trip...

Page 10: ...B B HH ON Delay Time 00 99 Shift Alarm Alarm Alarm Alarm HH Coil at Alarm RYEN RYDN Shift Alarm Alarm Shift HH Setpoint 19999 19999 Shift H Setpoint H Deadband H ON Delay Time 19999 19999 0000 9999 00...

Page 11: ...H Lo trip H coil at alarm H Coil energized at alarm H Fnc H Coil de energized at alarm D P H Fnc H P Fnc HH setpoint HH deadband hysteresis HH ON delay time HH ON delay time seconds HH Deadband hyster...

Page 12: ...lay goes back automatically to Measuring Mode if the front buttons are left untouched for the specified time period while it is in one of the setting modes except the loop test output mode With this v...

Page 13: ...1 Preset time can be specified with Transition Time to Lockout Setting Mode in Advanced Setting Mode A Scale Scale Scale Scale Scale Set value Setting Parameters A Alarm Alarm PARAMETER Alarm setting...

Page 14: ...tile memory error reading 1 If the unit does not recover its function after the initialization repairing in the factory may be required Non volatile memory error writing Increase decrease the input si...

Reviews: