background image

MODEL: 47DV

47DV SPECIFICATIONS

ES-9501 Rev.16   Page 3/13

http://www.m-system.co.jp/

Protected time duration: No limit

INPUT SPECIFICATIONS

1 – 5V

0.6 – 5.4V

1M Ω minimum

MEASURING

RANGE

TYPE ID

OPERATIONAL

RANGE

INPUT

IMPEDANCE

±5V

-6 – +6V

1M Ω minimum

±200V

-240 – +240V

1M Ω minimum

±20V

-24 – +24V

1M Ω minimum

INPUT CODE: 1 (DC voltage)

4 – 20mA

2.4 – 21.6mA

10Ω

0 – 20mA

-2 – +22mA

10Ω

±200mA

-240 – +240mA

1Ω

±20mA

-24 – +24mA

10Ω

MEASURING

RANGE

TYPE ID

OPERATIONAL

RANGE

INPUT

IMPEDANCE

INPUT CODE: 2 (DC current)

DC OUTPUT SIGNAL SPECIFICATIONS

TYPE ID

LOAD

RESISTANCE

OPERATIONAL

RANGE

OUTPUT

RANGE

2000Ω

 minimum

-0.5

 – +5.5V

0

 – 5V

4000Ω

 minimum

-6

 – +6V

±5V

TYPE ID

LOAD

RESISTANCE

OPERATIONAL

RANGE

OUTPUT

RANGE

400Ω

 maximum

-2

 – +22mA

0

 – 20mA

400Ω

 maximum

2.4

 – 21.6mA

4

 – 20mA

8000Ω

 minimum

-12

 – +12V

±10V

VOLTAGE OUTPUT

CURRENT OUTPUT

I/O OPTIONS

■ Event Trigger Input: Dry contact or NPN open collector
Input current: ≤ 3 mA
Sensing: 6 V
Contact detecting: ≤ 1.5 V at ON; ≥ 3 V at OFF
Signal ID and Details
  S-TMR: Startup Timer
  Measuring starts in the predetermined time after detecting
  the signal turning on.
  TIMING: Timing
  Used for various timing hold functions
  ZERO: Forced Zero
  Forced Zero and tare adjustment are externally controlled
  when ZERO signal is turned on/off.
  HOLD: Hold data
  Reading measured signal stops and the last
  value is held when HOLD signal is turned on.
  RESET: Reset data
  The device is reset when RESET signal is turned on.
■ Alarm Output: Relay contact

Rated load: 250 V AC @ 3 A (cos ø = 1)
30 V DC @ 3 A (resistive load)
Maximum switching voltage: 250 V AC, 30 V DC
Maximum switching power: 750 VA, 90 W (resistive load)
Minimum load: 5 V DC @ 10 mA
Mechanical life: ≥ 5 × 10

6

 cycles (rate 180 cycles/min.)

■ Alarm Output: Photo MOSFET relay
Rated load: 120 V AC/DC @ 80 mA (resistive load)
ON resistance: 25 Ω
Permissible loss: 250 mW
■ Network Interface
Transmission: Half-duplex, asynchronous, no procedure
Interface: Conforms to TIA/EIA-485-A
Max. transmission distance: 500 meters
Baud rate: 1.2 – 38.4 kbps
Max. number of nodes: 31 (except the master)
Protocol: Modbus RTU
Parity: None, odd or even
Stop bit: 1 bit, 2 bits
Node address: 1 to 247
Media: Shielded twisted-pair cable (CPEV-S 0.9 dia.)
Terminating resistor: Built-in (Connect across T2 - T3, when
the unit is the end of the line)
■ BCD Control Signals
• Input Signals: Dry contact or NPN open collector
Input current: ≤ 3 mA
Sensing: 6 V
Contact detecting: ≤ 1.5 V at ON; ≥ 3 V at OFF
Signal ID and Details
  REQ: Request BCD data
  Valid data in approx. 30 msec. after detecting
  the signal’s rising edge
  MIN_REQ: Request Minimum reading data
  Valid data in approx. 30 msec. after detecting
  the signal’s rising edge
  MAX_REQ: Request Maximum reading data
  Valid data in approx. 30 msec. after detecting
  the signal’s rising edge
  HOLD: Hold data
  Reading measured signal stops and the last value
  is held when HOLD signal is turned on.
  RESET: Reset data
  All BCD data turn off when RESET signal is turned
  on.
• Output Signals: NPN open collector
Max. load voltage: 24 V DC
Max. load current: 10 mA
Saturation voltage: ≤ 0.3 V
Leakage current: ≤ 500 μA
Signal ID and Details
  DATA (Do 11...Do 68): BCD Output data in 6 digits
  Do 1x = LSD ... Do 6x = 6th LSD

Summary of Contents for 47DV

Page 1: ...rm output N O relay 4 points 2 Alarm output SPDT relay 2 points 3 Alarm output N O photo MOSFET relay 4 points CE not available 4 Network interface RS 485 Modbus RTU 5 BCD output 6 Event trigger input...

Page 2: ...n depending upon setting S ERR main display and UNDER or OVER sub display blinking when the input signal is out of the usable range Bargraph No of LED segments 20 displayed with divided by 10 Color Am...

Page 3: ...30 V DC 3 A resistive load Maximum switching voltage 250 V AC 30 V DC Maximum switching power 750 VA 90 W resistive load Minimum load 5 V DC 10 mA Mechanical life 5 10 6 cycles rate 180 cycles min Ala...

Page 4: ...Mounting Panel flush mounting Weight 300 g 0 66 lb PERFORMANCE Accuracy Display Voltage input 0 03 1 digit Current input 0 1 1 digit Output 0 1 DC output display output Temp coefficient 0 015 C 0 008...

Page 5: ...rared interface Used for the infrared communication 8 Max Min button Used to switch the main display to show present values maximum values or minimum values etc 9 Alarm button Used to confirm alarm se...

Page 6: ...3 60 4 M3 SCREW REAR VIEW No Options BCD Output Event Trigger Input Alarm Output Photo MOSFET Relay Alarm Output RS 485 Modbus FRONT VIEW SIDE VIEW TOP VIEW 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1...

Page 7: ...MODEL 47DV 47DV SPECIFICATIONS ES 9501 Rev 16 Page 7 13 http www m system co jp MOUNTING REQUIREMENTS unit mm 92 0 8 0 45 0 6 0 min 120 min 75 Panel thickness 1 6 to 8 0 mm...

Page 8: ...el REM2 250 is provided separately Attach the REM2 to the terminals 3 4 as shown below Excitation Supply Connection Examples TERMINAL A BASIC 3 4 6 5 2 3 4 6 5 1 250 4 20mA DC sensor output sensor exc...

Page 9: ...TPUT HH OUTPUT RS 485 Modbus RTU 13 14 17 15 16 12 11 Digital Computation 20 18 19 Alarm Output SPDT contact 2 points 13 14 12 11 Digital Computation Lc COM Lb NC La NO Hc COM Hb NC Ha NO 17 15 16 20...

Page 10: ...D Output CONNECTOR Connector Pin Assignment PIN NO 1A 2A 3A 4A 5A 6A 7A 8A 9A 10A 11A 12A 13A 14A 15A 16A 17A 18A 19A 20A 21A 22A 23A 24A 25A ASSIGNMENT COM COM LL L PASS H HH POL RESET HOL D MIN_REQ...

Page 11: ...y contact NPN open collector TERMINAL D Alarm Output Photo MOSFET Relay N O contact 4 points 13 11 12 Digital Computation Ry 16 14 15 Ry Ry Ry Lc LLc LLa La Hc HHc Ha HHa LL OUTPUT L OUTPUT H OUTPUT H...

Page 12: ...16 ms after that When DATA output logic is negative wired OR connection is available for BCD data POL OVF HH H P L and LL signals Measured data is output every 64 ms while one of REQ signals REQ MAX_...

Page 13: ...r model 47Dx Lightning Surge Protector for RS 485 422 model MD74R or MDP 4R 1 Lightning Surge Protector for RS 485 422 model MD74R or MDP 4R 1 1 Insert lightning surge protectors recommended in this e...