background image

MODEL: 47DV

47DV SPECIFICATIONS

ES-9501 Rev.16   Page 11/13

http://www.m-system.co.jp/

TIMING
S-TMR
HOLD
RESET
ZERO

: 11
: 12
: 13
: 14
: 15

+6 V

2 kΩ

1.5 kΩ

16

COM

dry
contact

NPN
open
collector

TERMINAL D

• Alarm Output : Photo MOSFET Relay N.O. contact, 4 points

13

11

12

Digital

Computation

Ry

16

14

15

Ry

Ry

Ry

Lc, LLc

LLa

La

Hc, HHc

Ha

HHa

LL OUTPUT

L OUTPUT

H OUTPUT

HH OUTPUT

• Event Trigger Input

Digital

Computation

COM

ZERO

RESET

HOLD

S-TMR

TIMING

13

11

12

16

14

15

Isolation

Digital

Computation

Connection Example

Summary of Contents for 47DV

Page 1: ...rm output N O relay 4 points 2 Alarm output SPDT relay 2 points 3 Alarm output N O photo MOSFET relay 4 points CE not available 4 Network interface RS 485 Modbus RTU 5 BCD output 6 Event trigger input...

Page 2: ...n depending upon setting S ERR main display and UNDER or OVER sub display blinking when the input signal is out of the usable range Bargraph No of LED segments 20 displayed with divided by 10 Color Am...

Page 3: ...30 V DC 3 A resistive load Maximum switching voltage 250 V AC 30 V DC Maximum switching power 750 VA 90 W resistive load Minimum load 5 V DC 10 mA Mechanical life 5 10 6 cycles rate 180 cycles min Ala...

Page 4: ...Mounting Panel flush mounting Weight 300 g 0 66 lb PERFORMANCE Accuracy Display Voltage input 0 03 1 digit Current input 0 1 1 digit Output 0 1 DC output display output Temp coefficient 0 015 C 0 008...

Page 5: ...rared interface Used for the infrared communication 8 Max Min button Used to switch the main display to show present values maximum values or minimum values etc 9 Alarm button Used to confirm alarm se...

Page 6: ...3 60 4 M3 SCREW REAR VIEW No Options BCD Output Event Trigger Input Alarm Output Photo MOSFET Relay Alarm Output RS 485 Modbus FRONT VIEW SIDE VIEW TOP VIEW 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1...

Page 7: ...MODEL 47DV 47DV SPECIFICATIONS ES 9501 Rev 16 Page 7 13 http www m system co jp MOUNTING REQUIREMENTS unit mm 92 0 8 0 45 0 6 0 min 120 min 75 Panel thickness 1 6 to 8 0 mm...

Page 8: ...el REM2 250 is provided separately Attach the REM2 to the terminals 3 4 as shown below Excitation Supply Connection Examples TERMINAL A BASIC 3 4 6 5 2 3 4 6 5 1 250 4 20mA DC sensor output sensor exc...

Page 9: ...TPUT HH OUTPUT RS 485 Modbus RTU 13 14 17 15 16 12 11 Digital Computation 20 18 19 Alarm Output SPDT contact 2 points 13 14 12 11 Digital Computation Lc COM Lb NC La NO Hc COM Hb NC Ha NO 17 15 16 20...

Page 10: ...D Output CONNECTOR Connector Pin Assignment PIN NO 1A 2A 3A 4A 5A 6A 7A 8A 9A 10A 11A 12A 13A 14A 15A 16A 17A 18A 19A 20A 21A 22A 23A 24A 25A ASSIGNMENT COM COM LL L PASS H HH POL RESET HOL D MIN_REQ...

Page 11: ...y contact NPN open collector TERMINAL D Alarm Output Photo MOSFET Relay N O contact 4 points 13 11 12 Digital Computation Ry 16 14 15 Ry Ry Ry Lc LLc LLa La Hc HHc Ha HHa LL OUTPUT L OUTPUT H OUTPUT H...

Page 12: ...16 ms after that When DATA output logic is negative wired OR connection is available for BCD data POL OVF HH H P L and LL signals Measured data is output every 64 ms while one of REQ signals REQ MAX_...

Page 13: ...r model 47Dx Lightning Surge Protector for RS 485 422 model MD74R or MDP 4R 1 Lightning Surge Protector for RS 485 422 model MD74R or MDP 4R 1 1 Insert lightning surge protectors recommended in this e...