background image

8

www.m-locks.com

DELETING CODES / USERS

   

3

 

 

Press and hold ‘3’ until a double signal sounds. The LED will illuminate when performing the following 
actions:

9

   

8

   

7

   

6

   

5

   

4

  

 

•  Enter your personal Manager Code 

   

1

 

 

•  Enter User ID (1-9).
The user has been deleted.

10 

SETTING TIME DELAY AND OPENING WINDOW

Time delay:  

The time between the first and second code entry in minutes.

Opening window time:   

The period of time in minutes during which the code can be entered a second 
time and the lock can be opened.

   

9

 

 

Press and hold ‘9’ until a double signal sounds. The LED will illuminate when performing the following 
actions:

9

   

8

   

7

   

6

   

5

   

4

  

 

•  Enter the Manager Code 

2

   

6

   

0

   

2

  

 

•  Enter the delay setting and opening window time. Time delay min. 01 - max. 99 minutes. 
  Opening window time min. 01 - max. 19 minutes.
  In this example: 2602 for 

a delay of 26 minutes

 and 

an opening window time of 2 minutes

  

2

   

6

   

0

   

2

  

 

•  Enter the delay setting and opening window time again 

Summary of Contents for E-Pass

Page 1: ...E Pass EP1750 All versions M LOCKS BV Vlijtstraat 40 7005 BN Doetinchem The Netherlands www m locks com User manual V02 EN...

Page 2: ...2 www m locks com...

Page 3: ...ck 4 Opening the lock with time delay 5 Locking 6 Changing code with the door open Manager instructions 7 Adding codes users 8 Disabling enabling users 9 Deleting codes users 10 Setting time delay and...

Page 4: ...flash every 10 seconds and a long tone sounds when attempting to make an entry Entering an incorrect code on two further occasions after the keypad has been re enabled will trigger a new keypad lock...

Page 5: ...u will forfeit your right to warranty 2 SYMBOLS AND SIGNALS double audible tone correct entry LED flashes 1 2 digit on keypad long audible tone incorrect entry LED illuminated press and hold 3 OPENING...

Page 6: ...expires without entering a valid code the lock is secured again with time delay Press a random key to break off time delay 5 LOCKING Close the door and turn the handle until the stop to the left The...

Page 7: ...the new User Code 9 9 9 9 9 9 Enter the new User Code again If an incorrect code is entered on the second occasion a long signal sounds and the old code remains valid If the new code matches at least...

Page 8: ...Opening window time The period of time in minutes during which the code can be entered a second time and the lock can be opened 9 Press and hold 9 until a double signal sounds The LED will illuminate...

Page 9: ...when performing the following actions 9 8 7 6 5 4 Enter the Manager Code 0 0 0 1 Delete the time delay and opening window by entering 00 for the delay setting and 01 for the opening window 0 0 0 1 Ent...

Page 10: ...4 TROUBLESHOOTING The lock does not react a Replace the battery Always first replace the battery for a new 9V ALKALINE Duracell Duracell Industrial Procell or Energizer alkaline block battery b Check...

Page 11: ...11 www m locks com E Pass V02 EN...

Page 12: ...M LOCKS BV Vlijtstraat 40 7005 BN Doetinchem The Netherlands www m locks com...