background image

7

www.m-locks.com

E-Pass

V02

EN

 

MANAGER INSTRUCTIONS

ADDING CODES / USERS

With the manager code, up to nine additional opening codes can be added or deleted.

   

1

 

 

Press and hold ‘1’ until a double signal sounds. The LED will illuminate when performing the following 
actions:

9

   

8

   

7

   

6

   

5

   

4

  

 

•  Enter your personal Manager Code 

   

1

 

 

•  Enter User ID (1-9). If already occupied a long signal sounds.

For example:

9

   

9

   

9

   

9

   

9

   

9

  

 

•  Enter the new User Code 

9

   

9

   

9

   

9

   

9

   

9

  

 

•  Enter the new User Code again 

If an incorrect code is entered on the second occasion a long signal sounds and the old code remains 
valid.
If the new code matches at least 5 digits with an already existing code the new code is not accepted. 
Another user code must be selected and the entire process repeated.

DISABLING /ENABLING USERS

   

2

 

 

Press and hold ‘2’ until a double signal sounds. The LED will illuminate when performing the following 
actions:

For example!

9

   

8

   

7

   

6

   

5

   

4

  

 

•  Enter your personal Manager Code 
All users are disabled.  Please repeat this procedure to enable all users.

Summary of Contents for E-Pass

Page 1: ...E Pass EP1750 All versions M LOCKS BV Vlijtstraat 40 7005 BN Doetinchem The Netherlands www m locks com User manual V02 EN...

Page 2: ...2 www m locks com...

Page 3: ...ck 4 Opening the lock with time delay 5 Locking 6 Changing code with the door open Manager instructions 7 Adding codes users 8 Disabling enabling users 9 Deleting codes users 10 Setting time delay and...

Page 4: ...flash every 10 seconds and a long tone sounds when attempting to make an entry Entering an incorrect code on two further occasions after the keypad has been re enabled will trigger a new keypad lock...

Page 5: ...u will forfeit your right to warranty 2 SYMBOLS AND SIGNALS double audible tone correct entry LED flashes 1 2 digit on keypad long audible tone incorrect entry LED illuminated press and hold 3 OPENING...

Page 6: ...expires without entering a valid code the lock is secured again with time delay Press a random key to break off time delay 5 LOCKING Close the door and turn the handle until the stop to the left The...

Page 7: ...the new User Code 9 9 9 9 9 9 Enter the new User Code again If an incorrect code is entered on the second occasion a long signal sounds and the old code remains valid If the new code matches at least...

Page 8: ...Opening window time The period of time in minutes during which the code can be entered a second time and the lock can be opened 9 Press and hold 9 until a double signal sounds The LED will illuminate...

Page 9: ...when performing the following actions 9 8 7 6 5 4 Enter the Manager Code 0 0 0 1 Delete the time delay and opening window by entering 00 for the delay setting and 01 for the opening window 0 0 0 1 Ent...

Page 10: ...4 TROUBLESHOOTING The lock does not react a Replace the battery Always first replace the battery for a new 9V ALKALINE Duracell Duracell Industrial Procell or Energizer alkaline block battery b Check...

Page 11: ...11 www m locks com E Pass V02 EN...

Page 12: ...M LOCKS BV Vlijtstraat 40 7005 BN Doetinchem The Netherlands www m locks com...