background image

5

www.m-locks.com

E-Pass

V02

EN

!

  

Caution!

•   The lock has been designed for use in a temperature range from +10˚C to +50˚C and a non-

condensing humidity range from 30% to 80%. 

•  It may only be cleaned with a moist cloth (do not use aggressive cleaning agents).
•  The lock may only be installed by qualified fitters.
•  The lock may not be lubricated.
•   Never open the lock housing. If it is necessary to disassemble the hardware, only do so in accord-

ance with the technical instructions. If you fail to do so, the lock may no longer function properly 
and you will forfeit your right to warranty.

2

   SYMBOLS AND SIGNALS

double audible tone, 

correct 

entry

LED 

flashes

1

   

2

 ...

digit on keypad

long audible tone, 

incorrect 

entry

LED 

illuminated

press and hold

OPENING THE LOCK

1

   

2

   

3

   

4

   

5

   

6

  

Enter the code (Manager Code set at the factory = 1-2-3-4-5-6), if the code is correct a double signal 
sounds, turn the knob and open. If the door is not opened within 3 seconds the lock will automatically 
lock again. 

OPENING THE LOCK WITH TIME DELAY

For example:

1

   

1

   

1

   

1

   

1

   

1

  

 

Enter the code (e.g. 1-1-1-1-1-1), if the code is correct a double signal sounds and time delay starts. 
During time delay expires the light flashes every 10 seconds. After time delay has elapsed a double 
signal sounds and the open window starts.

Summary of Contents for E-Pass

Page 1: ...E Pass EP1750 All versions M LOCKS BV Vlijtstraat 40 7005 BN Doetinchem The Netherlands www m locks com User manual V02 EN...

Page 2: ...2 www m locks com...

Page 3: ...ck 4 Opening the lock with time delay 5 Locking 6 Changing code with the door open Manager instructions 7 Adding codes users 8 Disabling enabling users 9 Deleting codes users 10 Setting time delay and...

Page 4: ...flash every 10 seconds and a long tone sounds when attempting to make an entry Entering an incorrect code on two further occasions after the keypad has been re enabled will trigger a new keypad lock...

Page 5: ...u will forfeit your right to warranty 2 SYMBOLS AND SIGNALS double audible tone correct entry LED flashes 1 2 digit on keypad long audible tone incorrect entry LED illuminated press and hold 3 OPENING...

Page 6: ...expires without entering a valid code the lock is secured again with time delay Press a random key to break off time delay 5 LOCKING Close the door and turn the handle until the stop to the left The...

Page 7: ...the new User Code 9 9 9 9 9 9 Enter the new User Code again If an incorrect code is entered on the second occasion a long signal sounds and the old code remains valid If the new code matches at least...

Page 8: ...Opening window time The period of time in minutes during which the code can be entered a second time and the lock can be opened 9 Press and hold 9 until a double signal sounds The LED will illuminate...

Page 9: ...when performing the following actions 9 8 7 6 5 4 Enter the Manager Code 0 0 0 1 Delete the time delay and opening window by entering 00 for the delay setting and 01 for the opening window 0 0 0 1 Ent...

Page 10: ...4 TROUBLESHOOTING The lock does not react a Replace the battery Always first replace the battery for a new 9V ALKALINE Duracell Duracell Industrial Procell or Energizer alkaline block battery b Check...

Page 11: ...11 www m locks com E Pass V02 EN...

Page 12: ...M LOCKS BV Vlijtstraat 40 7005 BN Doetinchem The Netherlands www m locks com...

Reviews: