unit from falling out, use the supplied installation aid (16). It is 
easily screwed to the wall box using one of the Torx screws and 
holds the outer unit in position.

8.  Remove the cover over the screw terminals on the outer unit and 

feed the cable through the relevant inlet.

9.  Now connect the cable to the intercom system. 
  (See Point CONNECTION)

Adjustment of nameplate and indicator field

The nameplate consists of two transparent plastic parts, which are 
joined together with 2 respectively 4 small screws.

10. Remove both screws on the nameplate and take it apart; the foil 

for inscription is between the plastic parts.

11.  Write on the foil with a smear-resistant felt pen or print a name-

plate inlay* using a PC and a printer.

12.  Place the written nameplate inlay between the two plastic parts 

and screw these back together.

* Nameplate size:
VDV 810, VDV 820 and VDV 830: 71mm x 34mm
VDV 840 and VDV 860: 71mm x 15 mm

The indicator field likewise consists of two plastic parts; one is 
permanently affixed to the outer unit and the other is simply clipped 
over the top and can be pulled off from the front. Write on the foil with 
a smear-resistant felt pen or print an inlay sized 72 x 62 mm using a 
PC and a printer.

13.  In order to replace the front cover on the outside station, the 

inscribed indicator field must be placed correctly on the outside 
station.

14. Place the nameplate on the outside station and affix it with the 

supplied adhesive strip so that it cannot fall out. Alternatively you 
can affix the nameplate with transparent adhesive tape.

15.  Remove the installation aid and assure the outdoor unit by hand 

against falling out. A second person can be very helpful here.

16.  Place the front cover onto the outside station. 
17.  Screw on the front cover with the 6 supplied Torx screws. 
  Be careful not to cant or over-tighten the screws. 

The maximum 

torque is 1,2 Nm

. This value must not be exceeded. Otherwise, 

the threaded inserts in the wall box will become unusable or 

  be torn out.

Note

: Self-adhesive foam is supplied to seal the front plate against 

water. It is affixed to the edge of the front plate from behind.

CONNECTION

Connect the laid line to Audio, +15V, GND and Video (figure 2.1, no. 
14) on the outdoor station and connect it with the indoor station/s. 
These are also present on the indoor station and need only be 
connected with one another 1:1.

Note on the multi-family house version

: one 4-pole connection 

terminal is provided per residential unit; the connector terminals are 
numbered. Terminal 1 is for the lowest bell button, terminal 2 for the 
bell button above it, etc. 

Connecting a door opener

The door opener is connected directly to the outdoor station by two 

lines (figure 2.2, no. 12). No additional power supply is necessary 
to control the door opener. The door opener must be designed for 12 
V direct current and may not require more than 1 A current. The two 
connector terminals are marked ‘lock +’ and ‘lock –‘ if the door opener 
needs to be poled.
 

Connecting the power supply

The power supply can either be connected to the indoor and/or to the 
outdoor station. Separate screw terminals exist for this purpose (figure 
2.2, no. 13). It is also possible to connect the power supply directly to 
the signal line, e.g. if all signal lines have been laid from the fuse box 
to the outdoor and indoor units. The power supply unit then needs to be 
connected with earth (GND) and +15V (figure 2.1, no. 14).

Up to 8 units can be supplied with power from one power supply unit. A 
second power supply unit is required if there are more than eight units, 
e.g. if 2 outdoor and 7 indoor stations need to be used.

The second power supply unit can simply be switched parallel to the 
first power supply unit.
The second power supply unit should be connected with a short line to 
the indoor or outdoor station that is farthest away so that any drop in 
current in the connection line can be compensated. 

Connecting an external camera

An external camera can be connected to this screw terminal (figure 2.3, 
no. 15) in order, for example, to provide additional monitoring of areas 
that cannot be seen by the main camera. All cameras can be connected 
that require operating voltage of 12 V DC and supply an FBAS video 
signal. 
The video line is connected to the terminal (VIDEO) and the earth line 
to the terminal (GND), operating voltage for the camera is taken from 
the terminals ‘VCC’ (positive pole) and ‘GND’ (negative pole).
The external camera automatically has the ID 4 (see chapter on ID 
code). 
No sound transmission is possible when the external camera is active. 

POSSIBLE SETTINGS

The outdoor station offers the following possibilities to set the system 
to your personal circumstances:

Volume of the outdoor station

The potentiometer (figure 2.3, no. 9) is used to set the volume on 
the outdoor station. To set the highest volume, turn the potentiometer 
carefully clockwise as far as possible and then back a little. Reduce the 
volume by turning in an anti-clockwise direction.

ID code

If several outdoor stations are switched in parallel (e.g. at the gate 
entrance and the house) then the ID code is set via the dip switch 
(figure 2.2, no. 11). This makes it possible to activate the individual 
outdoor units in sequence, e.g. in order to monitor the coverage of the 
relevant outdoor unit. The switch is carried out on the indoor station 
with the ‘monitor’ switch. 

ID1 = Switch 1 ‘on’ Switch 2 ‘on’
ID2 = Switch 1 ‘off’ Switch 2 ‘on’
ID3 = Switch 1 ‘off’ Switch 2 ‘off’

1,2 Nm

VDV-800_I-Manual_Fin2.indd   8

26.10.12   12:17

Summary of Contents for VISTADOOR VDV-800

Page 1: ...VDV 800 BETRIEBSANLEITUNG OPERATING INSTRUCTIONS MODE D EMPLOI GEBRUIKSAANWIJZING VDV 800_I Manual_Fin2 indd 1 26 10 12 12 17...

Page 2: ...AGRAM 1 ILLUSTRATION 1 AFBEELDING 1 Abb 2 DIAGRAM 2 ILLUSTRATION 2 AFBEELDING 2 Abb 3 DIAGRAM 3 ILLUSTRATION 3 AFBEELDING 3 1 4 3 1 1 2 1 2 3 14 11 12 13 10 15 9 16 1 2 2 2 16 2 8 1 2 Nm VDV 800_I Man...

Page 3: ...t der Hauswand abschlie t 4 Um die Unterputzschale mit der Wand zu verankern markieren Sie zun chst mittels der L cher im Boden der UP Schale die 4 u eren Befestigungsl cher an der Wand und bohren Sie...

Page 4: ...le nicht ausreichend fixiert k nnen Sie die Hohlr ume an den Seiten mit geeignetem Kleber f llen 6 Beim Verputzen stecken Sie die mitgelieferte Einputzhilfe in die UP Schale Dadurch wird verhindert da...

Page 5: ...elektrischen oder hochfre quenten Feldern Entladungen Mobiltelefonen Funkanlagen Handys Mikrowellen kann es zu Funktionsbeeintr chtigungen der Ger te des Ger tes kommen Reinigung und Pflege Netzbetri...

Page 6: ...hen Einrichtungen sind die Unfallverh tungsvorschriften des Verbandes der gewerblichen Berufsgenossenschaften f r elektrische Anlagen und Betriebsmittel zu beachten Wenden Sie sich an eine Fachkraft w...

Page 7: ...tion or in a star formation from a central point distribution box The lines should be laid in such a way that they are fed out of the wall directly behind the relevant outdoor indoor unit Note It is a...

Page 8: ...ner is connected directly to the outdoor station by two lines figure 2 2 no 12 No additional power supply is necessary to control the door opener The door opener must be designed for 12 V direct curre...

Page 9: ...LIFE Unplug the mains connector from the socket Damage should be repaired immediately by a specialist Never carry out repairs yourself Warranty 2 years warranty from date of purchasing on base of cor...

Page 10: ...chaque unit d habitation Exemple VDV 840 16 c bles pour les appartements sont n cessaires au niveau de l unit ext rieure respectivement 4 c bles x 4 sonnettes et 2 c bles pour la g che Il est possible...

Page 11: ...es dans les trous Fixez maintenant le bo tier encastrable avec les vis Veillez ce que le bo tier encastrable soit bien de niveau v rifiez le cas ch ant l aide d un niveau bulle Le bo tier encastrable...

Page 12: ...tion arbitraire du produit est interdite Le montage du produit correspond la classe de s curit 1 L alimentation en courant ne doit s effectuer que par une prise 230V 50Hz raccord e au r seau d aliment...

Page 13: ...choc lectrique mortel Dans les installations industrielles il convient d observer les consignes de pr vention d accidents relatives aux installations et moyens d exploitation dict es par les syndicats...

Page 14: ...r binnenstation worden gelegd of stervormig vanuit een centraal punt verdeelkast De leidingen moeten zo aangelegd zijn dat ze telkens direct achter de overeenkomstige buiten binnenunit uit de wand wor...

Page 15: ...n Opmerking voor versies van meergezinswoningen Per wooneenheid is een 4 polige aansluitklem voorzien De aansluitklem men zijn genummerd Aansluitklem 1 is voor de onderste oproeptoets aansluitklem 2 v...

Page 16: ...gebruik te worden gesteld en de voedingsleidingen afgesloten te worden STROOMSCHOK LEVENSGEVAAR Stroomstekker uit het stopcontact trekken Schade onmiddellijk door een vakman laten herstellen U mag zel...

Page 17: ...houden zonder voorafgaandelijke kennisgeving In het kader van onze productverzorging en optimalisering van onze toe stellen kan de inhoud afwijken van de vermeldingen op de verpakking NL Deze gebruiks...

Page 18: ...VDV 800_I Manual_Fin2 indd 18 26 10 12 12 17...

Page 19: ...LUSTRATION 1 AFBEELDING 1 Abb 2 DIAGRAM 2 ILLUSTRATION 2 AFBEELDING 2 Abb 3 DIAGRAM 3 ILLUSTRATION 3 AFBEELDING 3 1 4 3 1 1 2 1 2 3 14 11 12 13 10 15 9 16 1 2 2 2 16 2 8 1 2 Nm VDV 800_I Manual_Fin2 i...

Page 20: ...in bereinstimmung mit den grundlegenden Anforderungen und den brigen einschl gigen Bestimmungen befindet KONFORMIT TSERKL RUNG kann unter folgender Adresse gefunden werden http www m e de download ce...

Reviews: