WARNING! When connecting chimney from behind so you have to remove the
cap on the chimney shell and the stopper ( see arrow Pic.5 ) and then the stopper fitted to
the top slot, which will remain free to disassembling the chimney.
2.3 SAFE DISTANCE FIREPLACE STOVES TYPE „Zino“ FROM FLAMMABLE MATERI-
ALS, LOCATION FIREPLACE STOVES AND SMOKE EXTRACTION
Appliance type series „ZINO“ must be installed in accordance with Decree MV SR No. 95/2004
statute, coll establishing specifications and requirements for fire safety during installations and
operation of heating appliances, electro thermal appliances and central heating installations
and the constructions and use of chimneys and flues. It is also necessary to respect the STN 73
4210 „Running of the chimneys and flues and connecting fuel appliances. “ The manufacturer re-
commends the installation of the fireplace appliance type series „ZINO“conducted by a Qualified
Professional who is responsible for the materials used for installation, and can issue Certification
for Local Building Control and HETAS Registration. The manufacturer is only responsible for the
delivered product.
Caution: The Installer has to approve the fireplace before the initial operation and
issue a certificate about the safe utilisation and the correct flue gas evacuation
(HETAS Certification)
In the band of radiation ensure that no flammable parts or furniture are allowed up to a distance
of 100cm. due to the radiation of heat from the front of the stove.
The fireplace type series „ZINO“must be installed so that before it left space on the layout, about
1 x 1 m.
The base under appliance type series „ZINO“must be placed on a non combustible material that
will withstand heat stress. Also, all wall and ceiling materials, which the Appliance type series
„ZINO“ may be near must be non combustible materials, respect should also be used for good
thermal insulation.
Combustion pipe must be fitted to the fireplace chimney’s mouthpiece Appliance type series
„ZINO“so that it is firmly and tightly connected.
Combustion pipe can join at the top ( see Pic.4 ) or from behind ( see Pic.5 ). The average of
the flue is 150 mm.
Pic. 4
Pic. 5
Caution: The Installer has to approve the fireplace before the initial operation and