background image

6.2  Drawing 

12

Summary of Contents for ZINO 700

Page 1: ...INSTRUCTIONS FOR INSTALLATION AND USE OF ZINO 700 900 1100 ...

Page 2: ...TARTING THE FIRE 3 2 INSTALLATION 4 2 1 ACTIONS TO BE TAKEN UPON INSTALLATION 4 2 2 LIST OF STANDARDS TO BE OBSERVED DURING ASSEMBLY AND OPERATIONS 4 2 3 SAFE DISTANCE FIREPLACE STOVES TYPE Zino FROM FLAMMABLE 5 MATERIALS LOCATION FIREPLACE STOVES AND SMOKE EXTRACT 2 4 LOCATION the FIREPLACE FURNACE type series zino on the floor 6 2 4 1 REQUIREMENTS FOR PASSING COMBUSTION AIS 6 3 SECURITY CONDITIO...

Page 3: ...lves of woods of the 2kg weight are equal 5 7kW 1 2 2 Optimal operation Optimal use of fuel and optimal operation of the stove reach loading approx 1 5kg of wood lying on the floor of the fire chamber laid side to side of the combustion chamber The draught of chimney should be a minimum of 12 Pa and the regulator set for maximum air supply 1 2 3 Forbidden fuel The use of treated wood painted etc a...

Page 4: ... The appliance has to be installed according to certain prescribes rules and local regulations The device must be built in an area with an adequate strength capacity on the floor boards which can spread the weight of the stove The stove must be positioned so as to maintain the safety distances from any flammable materials However if you decide to carry out the work on your own we advise you to do ...

Page 5: ...or Local Building Control and HETAS Registration The manufacturer is only responsible for the delivered product Caution The Installer has to approve the fireplace before the initial operation and issue a certificate about the safe utilisation and the correct flue gas evacuation HETAS Certification In the band of radiation ensure that no flammable parts or furniture are allowed up to a distance of ...

Page 6: ...r safe and reliable operation 2 4 LOCATION THE FIREPLACE FURNACE TYPE SERIES ZINO ON THE FLOOR In front of the door inflammable floors need to be protected by placing the stove on a non combu stible material Stone Glass Marble Ceramic Tiles Etc The hearth needs to project at least 30cm in front of the door and 30 cm at the sides and back if against a dry lined wall however if the walls are constru...

Page 7: ...ype series ZINO are used Fire in the fireplace furnace type series ZINO must never be extinguish with water The space where it is located fireplace type series ZINO must be ensured there is an ade quate supply of air for combustion of the fuel Loading doors must be kept closed when running the stove furnace type series ZINO always keep closed when burning except when refuelling They are allowed no...

Page 8: ... season by intensity of use and according to characteristics of the fuel need to check and clean the flue gas path of ash and shoot Choose to be two deflector plates Deflector plate 1 skamol with the stainless holder and deflector refractory plate 2 see Pic 11 After the cleaning the flue tract and insertion of parts back to its position check the parts are properly stored and secured in position s...

Page 9: ...ne one side and downward on a diagonal and sliding the plate in the chamber and then out The installation of the pass refractory plate 2 Slide plate on a diagonal into the combustion chamber and to push all the way to the top flue out let and insert holders for No 1 and No 2 see Pic 12 The installation of the deflector plate 1 Slide plate on a diagonal to the fireplace stoves and push up and place...

Page 10: ...power kW 4 4 6 5 Average efficienty 82 81 5 80 5 Heat flow into the space kW 4 4 6 5 Power range kW 3 6 3 7 3 8 Flue gas temperature at rated output c 163 158 152 Avg CO concentration at 13 O2 0 105 0 11 0 118 The average volume concentration of CO at 13 O2 mg m 1311 1378 1475 Minimum blast Pa 12 12 12 The weight of the fireplace furnance kg 130 150 165 Minimum distance from flammable materials fr...

Page 11: ...6 1 Spare parts 11 ...

Page 12: ...6 2 Drawing 12 ...

Page 13: ...s not apply to defects caused by impurities in the fuel combustion gas inappropriate improper placement and the inevitable damage caused by the event natural disas ter etc 4 The guarantee also does not apply to damages caused indirectly and damage or personal injury cases 5 The claims for non compliance security guarantees expire the expiry of the guarantee pe riod repair or modification of the fi...

Reviews: