230V
8
Instructions for installation and use - Venus True Vision Gas
English
NEARBOX
Connection Gas 1/2” (provide tap)
Opening provided in wall
for maintenance
Cable to ionistation pin
GAS SUPPLY TO MAIN BURNER ( RED)
flexible for GAS
True Vision is provided with
a direct ignition , no starting
pilot
3.3 The Gas connection
Valve 1/2”
After the “NEARBOX” has removed from the of the back of the fire, you can place it loosely
on the ground in proximity to the opening provided in the wall of mantelpiece. The device
is always connected with an approved gas tap 1/2, and preferably with a yellow gasflexible
that is reachable at all times. Provide the mantelpiece with a door so that the valve and
the electrical connection is easily accessible.
GAS SUPPLY TO SIDE BURNER OR SECOND
BURNER (YELLOW)
Flexibel
Gas provider
3.4 Electrical connection
These appliances are equipped with a radiographic remote control, making an earthened
220V socket necessary. You should bear in mind that the appliance must be connected to all
electrical supplies for the purposes of service. It’s obligatory to connect an earth current.
3.1.5 Modification natural gaz to propane
Modification of the fireplace can only be done by the manufacturer or an approved
installer. A new signal plate is provided.