4 dm
2
2 dm
2
ATTENTION:
if the installer opens the openings in advance, these must be covered during the work
(grinding, drilling, sawing, etc.). Dust released during installation will otherwise sneak into
convection circuit. Dust can never be eliminated properly and give off a lingering smell when
using the appliance.
Once the installation is complete, it is imperative to aspirate or blow the convection
channels with compressed air (be sure not to return dust to the convection chamber of the
fireplace).
15
Instructions for installation and use - Venus True Vision Gas
English
Design Grills (outlet )
with to connectors
Outlet
Design Grill Long (outlet)
Inlet Grill
Inlet Grill
Inlet
Inlet
Outlet
EXIT CONVECTION:
You can choose between 3 models of grids according to your taste or
according to the fireplace: Grid Design (2 connections), Grille design long small model (2
connections) or long model (4 connections)
AIR ARRIVAL (ENTRY CONVECTION)
: You have the option to choose between inlets 2dm²
or 4dm²
7.1. Convection grills