13
A
B
C
A
B
C
A
B
C
A
B
C
Instructions for installation and use TRUE VISION 1000-1300RD Gas
Appliance
Ø 200/130
1000 / 1300 RD
for each 90° bend subtract 1m horizontally or add 1m vertically
1000 / 1300 RD
for each 45°/30°/15° bend subtract 0,5m horizontally or add 0,5 m vertically
Picture 4: ROOF EXIT WITH BEND
Ø 200/130
Appliance
A (min)
B (max)
C (min)
(A+B+C )max
True Vision 1000 RD
1 m
A+C
B-A
12m
True Vision 1300 RD
1 m
A+C - 1m
B-A-81
10m