![M Design Luna Diamond Series Instructions For Installation And Use Manual Download Page 8](http://html1.mh-extra.com/html/m-design/luna-diamond-series/luna-diamond-series_instructions-for-installation-and-use-manual_3182656008.webp)
GAS SUPPLY TO SIDE BURNER OR SECOND
BURNER (YELLOW)
220V
NEARBOX
Connection Gas 1/2” (provide tap)
8
Opening provided in wall
for maintenance
Cable to ionistation pin
GAS SUPPLY TO MAIN BURNER ( RED)
flexible for GAS
The appliance is provided
with a direct ignition , no
starting pilot
3.3. The Gas connection
Valve 1/2”
After the “NEARBOX” has removed from the of the back of the fire, you can place it loosely on the ground
in proximity to the opening provided in the wall of mantelpiece. The device is always connected with an
approved gas tap 1/2, and preferably with a yellow gasflexible that is reachable at all times. Provide the
mantelpiece with a door so that the valve and the electrical connection is easily accessible.
ATTENTION : DO NOT PLACE ANY DECORATION ON THE DIRECT IGNITION PIN
(be carefull to stay out of the little rectangular zone with the dcoration)