The enclosure of the furnace must be provided with ventilation grills or openings allowing for the
elimination of heat by convection. It is possible to have a convection kit fitted with the furnace. This
system directs the heat inside the room by means of flexible tubes ( dia. 150 mm).
It is obligatory to open at least 2 hot air vents (
for the LUNA 1600 you must open 4
) at the top of the
appliance.
For the purposes of the installation of these ducts it is best to go vertically upwards first for at least 1m
and then to change direction, making a rather wide bend and avoid using a flue terminal grid with
a small clearance because the speed loss that this causes reduces the efficiency of the hot air vents.
Place all the fittings that you use at the same lengths and angles if possible, otherwise it is possible
that some grids give off more heat than others and, seeing that a hot air pipe functions in a manner
similar to a chimney, the one that is hot first has the most draught and therefore becomes hot even
more quickly.
Note:
a circulation of hot air requires that no under-pressure be created in the room. A grid that is
near the floor (pic 2) sees to it that cold air can be drawn in.
M-design has developed its ideal hot air grids which have many advantages (pic. 1 & 2) and for the
elimination of hot air and the entry of warm air we advise you to use those Design grills made by
M-Design.
The appertures for the air supply “IN” (pic.2) is situated underneath the appliances. The stove may
not be placed direct ont the floor to allow natural convection.
To simplify the mounting of the grids you can use the corner profile (a) wich is furnished with the
grid. This profile is can be mounted on the side of the grid (two little wholes en screws are provided).
.
6. CONVECTION CURRENT
Please , follow this instruction. The appliance can overheat if you not apply those instructi
-
ons. Errorcode F02 will appear !
OUT
pic. 1
(a)
INLET
pic. 2