INSTRUCTION FOR INSTALLATION AND USE - LUNA 1000-1300 RD GOLD - GAS
10
Pic. 3 WALL EXIT (C
11
)
Ø 200 / 130
Appliance
A (min)
B (min)
B (max)
Restriction
1000 RD
1 m
wall exit
A
Ø 75
1300 RD
1 m
wall exit
wall exit
Ø 75
A
=
M
IN
. 1
m
B
2
5
5
elbow min. 90°
3°
DO NOT USE A REDUCTION 200/130 to 150/100 IN THIS CASE
IMPORTANT
: BE CAREFULL EVERY HORIZONTAL PART DOES NOT HAVE AN
NEGATIVE INCLINATION (pic.5) IN DIRECTION OF OUTLET. IT IS EVEN BETTER, WHEN
POSSIBLE, TO HAVE A LITTLE INCLINATION OF 2 OR 3 DEGREES ASCENDING.
ONLY THE OUTLET MUST BE INSTALLED LIKE PIC. 6 ( TO AVOID RAIN DROPS IN TUBE )