Pic. 5 ROOF EXIT with 90° bends
CAUTION :
if the vertical lenght is over 3 meter
longer than the horizontal lenght, you will need to
place a reduction ring of
Ø 75.
Appliance
Ø 150/100 and Ø 200/130
1000 RD / 1300 RD
for each 90° bend substract 1 m horizontaly or add 1 m verticaly.
1000 RD / 1300 RD
for each 45° / 30° / 15° bend substract 0,5 m horizontaly or add 0,5 m
verticaly.
Ø 200/130
Appliance
A (min)
B (max)
C (min)
(A+B+C )max
1000 Rd
1 m
A+C
B-A-9m
12 m
1300 RD
1 m
A+C-1
B-A+1
10 m
FIG. 5