MCM JR-2 Current Interrupter
11640 US Hwy 1, Sebastian FL 32958
Tel: 772-794-9448 ~ Fax: 772-589-9072
E-mail:
~ Web Site:
www.mcmiller.com
Instruments and Equipment for the Corrosion Engineer
14
Procedure -All Units Display Reading
1. Power Switch ON PASS
2. Start Relay-Closed PASS
3. Press START SET, 8,0,0, ENTER (8AM) 8:00
4. Press STOP SET (6), 1,7,0,0, ENTER (5PM) 17:00
5. Press ON CYCLE, 2,0, ENTER (2 sec.) 2.00
6. Press OFF CYCLE, 5, ENTER (0.5 sec) .50
7. Interconnect "SYNC" jacks on all units, daisy
chain fashion.
8. Press CLOCK SET, 1,4,3,2. (2:32PM)
(press ENTER)
14:32
9. When present time (your wrist watch) reads 2:32
Press 'ENTER' once on one unit only 14:32
10. At 14:32, all units will display LOCh #
This is a countdown operation to show that the units are
performing a calculation. When the calculation is complete,
all the units will immediately commence cycling. Since the
relays are now in operation, try to maintain them in an
upright position during transport and installation.