background image

Oxygen Keyboard Line User Guide

23

English

14  ›  Technical Info

Caution:

 Electro Static Discharge, Electrical Fast Transient and Conducted RF interference may cause the unit malfunctioning. In such 

case, unplug the unit and plug it in again to restore normal operation.

Note:

 Your M-Audio product has been tested to comply with FCC Standards FOR HOME OR OFFICE USE. Modifications not authorized 

by the manufacturer may void users authority to operate this device.

Note

: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the 

FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This 
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, 
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular 
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Re-orient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/ TV technician for help.

ASIO

 is a trademark of Steinberg Soft– und Hardware GmbH.

VST

 is a trademark of Steinberg Soft– und Hardware GmbH

Oxygen Keyboard Line

Tested to comply with
FCC standards

FOR HOME OR STUDIO USE

15  ›  Warranty Terms and Registration

Warranty Terms

M-Audio warrants products to be free from defects in materials and workmanship, under normal use and provided that the product 
is  owned  by  the  original,  registered  user.    Visit  www.m-audio.com/warranty  for  terms  and  limitations  applying  to  your  specific 
product.

Warranty Registration

Thank you for registering your new M-Audio product. Doing so immediately both entitles you to full warranty coverage and helps M-
Audio develop and manufacture the finest quality products available. Register online at www.m-audio.com/register to receive FREE 
product updates.

 

Summary of Contents for Oxygen 49

Page 1: ...Oxygen Series Oxygen 8 v2 Oxygen 49 Oxygen 61 User Guide...

Page 2: ...ftware Editor replace with section s number of this manual or visit www m audio com to register and download the free software 2 What s in the Box Your Oxygen keyboard package contains the following 2...

Page 3: ...r 2000 You must be running Service Pack 1 SP1 or later Visit the Windows update web pages http windowsupdate microsoft com to make certain you have the most current updates and xes supplied by Microso...

Page 4: ...wering the Oxygen keyboard via USB then simply plug in the power supply to the input labelled DC 12V and switch the power on Note Do not leave the adapter plugged in for long periods if the unit is no...

Page 5: ...ay provides feedback while you are programming various MIDI functions 5 Function Buttons There are 7 function buttons on the 49 and 61 Note and 5 on 25 Note The Function buttons are used for on the y...

Page 6: ...the illustration The sustain pedal controls the hold length of any note played on the keyboard However the pedal is fully programmable and can be used to control other effects The polarity of the sus...

Page 7: ...keyboard s driver as the MIDI Input for your software In addition please read the troubleshooting section at the back of this manual and consult the manual that came with your software for proper con...

Page 8: ...The Select button is used to select the function of the 2 data buttons Each time the Select button is pressed a different dot will light along the bottom of the LED display to indicate which of the f...

Page 9: ...any of the standard 16 MIDI channels The Global MIDI Channel will affect the channel on which program changes bank changes and any controllers set to respond to the global channel will transmit To set...

Page 10: ...step through Program Changes The Program Change number shown in the LED display will be sent Bank LSB The Bank LSB function can be used to access additional banks of sounds on your sound module or sou...

Page 11: ...MIDI CC is listed along with the Data 1 2 and 3 functions When editing Data 3 values the range of values that can be selected is 0 127 To assign maximum value to a knob or fader 1 Press the Advanced...

Page 12: ...on button 2 Press the Drawbar key To exit the Drawbar function press the Drawbar button a second time Device ID 49 and 61 note only The Device ID function will allow the assigning of a Device ID to di...

Page 13: ...nced Function button 2 Press the Store key the last selected memory number will display 3 Type in the number of the memory to store settings and press Enter to save the changes All Store operations wi...

Page 14: ...dix A there is a wide variety of MIDI messages that can be assigned to controllers The uses of these messages will be explained in more detail in this section The assignable buttons and pedals have sl...

Page 15: ...Chorus Mod Depth GM2 Mod Depth 142 Feedback GM2 Feedback Level 143 Send to Reverb GM2 Reverb Send Level 144 Pitch Bend Pitch Shift LSB Pitch Shift MSB 145 Program Bank Preset Program Bank LSB Bank MSB...

Page 16: ...le the button value each time it is pressed It is possible to set the button to send one value when pressed and another value when released This is known as a trigger since each time you press the but...

Page 17: ...or the RPN NRPN MSB Press the Enter key to con rm 6 Press the Advanced Function button 7 Press the DATA 2 key and enter the desired number for the RPN NRPN LSB Press the Enter key to con rm 8 Press th...

Page 18: ...n the button to MIDI CC 154 The maximum and minimum values are set using the Data 3 and Data 2 parameters respectively Please note that each button will only increment or decrement its own parameter v...

Page 19: ...ry Dump the data will be ignored When the Dev ID key is pressed the LCD display represents the assigned Device ID It is possible to enter a new Device ID using the numerical data entry keys Press the...

Page 20: ...press the Channel Assign key you will enter a Device ID instead This is indicated by the fact that the LED displays a 3 digit number not a 2 digit number proceeded by a c Device IDs run from 00 to 127...

Page 21: ...rt phone PC support 418 872 0444 phone MAC support 418 872 0444 fax 418 872 0034 Sales e mail infocanada m audio com phone 866 872 0444 fax 514 396 7102 web http www m audio ca M Audio France Floor 6...

Page 22: ...o or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient or re...

Page 23: ...hannel Fine Tune Tuning Amount 130 Channel Coarse Tune Tuning Amount 131 Channel Pressure Pressure Amount 132 RPN Coarse Value RPN LSB RPN MSB 133 RPN Fine Value RPN LSB RPN MSB 134 NRPN Coarse Value...

Page 24: ...0B 11 36 54 61 97 0C 12 37 55 62 98 0D 13 38 56 63 99 0E 14 39 57 64 100 0F 15 3A 58 65 101 10 16 3B 59 66 102 11 17 3C 60 67 103 12 18 3D 61 68 104 13 19 3E 62 69 105 14 20 3F 63 6A 106 15 21 40 64 6...

Page 25: ...9 String Ensemble 2 50 Syn Strings 1 51 Syn Strings 2 52 Choir Aahs 53 Voice Oohs 54 Syn Choir 55 Orchestral Hit 80 Syn Square Wave 81 Syn Sawtooth Wave 82 Syn Calliope 83 Syn Chiff 84 Syn Charang 85...

Page 26: ...to 111 Controller 111 20 Controller 20 66 Sostenuto 112 Controller 112 21 Controller 21 67 Soft Pedal 113 Controller 113 22 Controller 22 68 Legato Pedal 114 Controller 114 23 Controller 23 69 Hold 2...

Page 27: ...7F n a 64 0 63 Drum EG Attack Rate relative change 17 00 7F 00 7F n a 64 0 63 Drum EG Decay Rate relative change 18 00 7F 00 7F n a 64 0 63 Drum Instrument Pitch Coarse relative change 19 00 7F 00 7F...

Reviews: