FES-LS8-M100 MOTOR manual Version 1.21
April 2020
Page 10 of 12
2.
Remove pitot tube assembly which is fixed on the back side of motor mounting plate.
To do that is necessary to unscrew two M5 bolts on top. Then carefully pull out pitot
tube assembly.
3.
Unlock two spring-locks which hold DB15 cable connector. Carefully unplug connector
from the socket of motor rear wall.
4.
Unscrew 3 locknuts from rear motor wall and disconnect 3 power cables. Each cable
is marked with different colour of isolation over the cable shoe (red, blue and black).
Take a photo so that you will know their proper order for assembly.
5.
Un-secure six M8 bolts and unscrew them (note that M8 screw located below power
cables has a lower head). To accomplish removal of the screws, support the motor
assembly.
6.
Take out motor assembly carefully. Note that centrifugal ventilator on the back side
of the motor has bigger diameter than rotor rink. It is not possible to get motor out
straight, as opening is not wide enough. It is necessary to rotate motor about 30
degrees to one side in order to get it out. Be careful not to damage spinner, or plastic
covers below spinner.