background image

Connections

Two matched modules are supplied an A and B version, these must be 
used together. Connections are identical for each module.  The system 
uses WDM fiber technology,  which allows for bidirectional connectivity 
over a single dedicated fiber link (closed loop)

The modules function as 3 port Ethernet switches with 2 standard RJ45 
electrical Ethernet ports and a fiber Ethernet port using a LC/PC optical 
connection on each module. Note a single dedicated fiber link is 
needed between locations. (LC simplex fiber connector shown below)

Power Lead Strain Relief

The module has a small hole in the case located above the power 
connection to prevent the power lead being accidentally pulled out. 
Use the supplied tie-wrap and secure the lead as shown below.

*

Note

The module must be used with SMF 
(singlemode) fiber cable.  Multimode cable does 
not support WDM and the link will not function.

The electrical port speeds can be set to 
automatic mode (10/100/1000) or 
forced to 10Mbit if required. It is also 
possible to configure automatic or 
manual crossover for the electrical 
ports (forced manual crossover is 
sometimes needed for older networks)

Note.

 

If  fiber RX LED is OFF this indicates no signal is present, signal to 

weak or is a non a valid signal.
 

Power

Each module requires a 12V DC power input and a LED is provided to 
confirm power is connected.  Power supplies are provided, but if 
applying your own power, please provide a clean 7-15V DC power input 
(12VDC nominal). Power consumption is approx 2.2W

Optional Mounting Bracket

The optional RFR 1001 mounting bracket  can be used to permanently 
mount the module on any flat surface or on 19” rack rails.  

Reviews: