Network Configuration  

The  network  feature  is  where  control  servers  are  configured  and  attachments 
between control servers and RCT 5023 rack controllers are made. It also where 
you configure the local COM ports. (This feature is available for blue and yellow) 

 

Current Infrastructure Configuration 

The current infrastructure configuration table, on the left, lists all control servers 
which  were  discovered  in  the  LynxCentraal  IP  network  via  ethernet  broadcast. 
Below each control server, is a list of its current controller attachments. Servers 
which are not permitted for the current operator, or servers which were filtered 
out by the current operator do not show up in this table. 

 

Available Rack Controllers 

The available rack controllers table, on the right, lists all RCT 5023 (and RCT 1012) 
rack controllers which were discovered in the LynxCentraal IP network via ethernet 
broadcast. 

Control  servers,  RCT  5023  (and  RCT  1012)  rack  controllers  which  reside  in 
different IP subnets can be added explicitly with the IP find tool in the upper right 
corner of the page. 

Options of Attaching a RCT 5023 Rack Controller to a Control SERVER 

1.

 

Select  an RCT  5023  (or  RCT  1012)  rack  controller from  the 

  table  and  drag  it  into  the 

 table, 

dropping it onto the desired control server.

 

2.

 

Select  an RCT  5023  (or  RCT  1012)  rack  controller in  the 

 table, open its context menu and select 

Attach

 This will present a 

dialog which allows you to pick the desired control server.

 

Summary of Contents for LynxCentraal 5000 Series

Page 1: ...ntraal Broadcast Television Equipment 5000 Series Quick Start Guide 2022 LYNXTechnik AG Page 1 LynxCentraal 5000 Series Quick Start Guide Revision 1 0 RELEASE Last Updated May 2022 Service Contact sup...

Page 2: ...patterns for greenMachine Testor custom control panels and other data between all workstations in the LYNX universe Since there was no such redundancy and advanced user management in the 5000 series i...

Page 3: ...ckly change settings in your environment LynxCentraal contains an enhanced redundancy management engine for synchronizing operator account information custom patterns for greenMachine Testor custom co...

Page 4: ...on a PC in the same network as your devices Start the application Login as Main Admin with the default password 1main admin the Main Admin password is NOT editable Select the Operator Feature Page it...

Page 5: ...wn or hot keys There is a dedicated page for each of the hardware device types Series 5000 blue greenMachine green and yellobrik yellow Functions which all devices share are available as additional pa...

Page 6: ...her via an IP network The RCT 5023 G is the basic controller card and is all you need to connect a Series 5000 2RU rack frame to the LynxCentraal Control software The controller card has a LAN network...

Page 7: ...individual IP address The entire system is accessible under two different IP addresses NOTE The processing boards will continue to work even if the Primary SERVER is not available In the event of a se...

Page 8: ...for the current operator or servers which were filtered out by the current operator do not show up in this table Available Rack Controllers The available rack controllers table on the right lists all...

Page 9: ...to three control servers Each server can assign an individual name to the controller Options of Detaching a RCT 5023 Rack Controller from a Control SERVER 1 Select the RCT 5023 or RCT 1012 rack contro...

Page 10: ...e LYNX RackController or LYNX Server in the list and do one of the following 1 If the system is connected to a network and you have a DHCP server Activate the DHCP checkbox so that the LYNX Controller...

Page 11: ...default factory setting admin password is lynx admin Repeat the above steps 1 or 2 for all LYNX RackControllers and LYNX Servers which need to be connected to your network NOTE If your LYNX component...

Page 12: ...input is removed the GUI will update the appropriate status information immediately usually within 500 msec NOTE Any changes to the configuration of a card by mouse click in the GUI are communicated d...

Reviews: