Lynx LynxCentraal 5000 Series Quick Start Manual Download Page 6

LYNX

Technik

 

AG

  

 

 

 

 

        LynxCentraal

 

 

Broadcast Television Equipment

  

5000 Series

 

Quick-Start Guide

 

©

 2022 

LYNX

Technik 

AG

 

 

Page 6

 

 

® 

Series 5000 Control Topology 

Series 5000 Controller 

A  typical  LYNX  Technik  Series 
5000  signal  processing  system 
consists  of  rack  frames  with 
boards,  rack  controllers,  and  the 
LynxCentraal  Control  system. 
Each  Series  5000  rack  frame 
requires an RCT 5023-G. For large 
configurations, 

an 

optional 

dedicated  control  server  running 
the  system  software,  can  be 
added. The rack controller and the 
control 

server 

are 

logically 

attached  to  each  other  via  an  IP 
network. 

The  RCT  5023-G  is  the  basic 
controller card and is all you need 
to connect a Series 5000 2RU rack frame to the LynxCentraal Control software. 
The controller card has a LAN network interface that uses the LAN connection on 
the  terminal  plate  of  the  rack  frame.  All  LAN  related  settings  are  stored  on  an 
internal  flash  memory.  Each  controller  card  in  one  system  needs  to  have  an 
individual IP-address. 

 

OH-RCT5023-SVR 

The  OH-RCT5023-SVR  option  is  an  inde-
pendent  Linux  Server  with  its  own  IP-
address. For power and LAN connection it is 
clipped as a piggyback onto the RCT 5023-
G controller card.  

Adding  the  OH-RCT5023-SVR  option  to  a 
system,  enables  features  like  full  SNMP 
support, Backup-Restore for the complete system and many more. 

Summary of Contents for LynxCentraal 5000 Series

Page 1: ...ntraal Broadcast Television Equipment 5000 Series Quick Start Guide 2022 LYNXTechnik AG Page 1 LynxCentraal 5000 Series Quick Start Guide Revision 1 0 RELEASE Last Updated May 2022 Service Contact sup...

Page 2: ...patterns for greenMachine Testor custom control panels and other data between all workstations in the LYNX universe Since there was no such redundancy and advanced user management in the 5000 series i...

Page 3: ...ckly change settings in your environment LynxCentraal contains an enhanced redundancy management engine for synchronizing operator account information custom patterns for greenMachine Testor custom co...

Page 4: ...on a PC in the same network as your devices Start the application Login as Main Admin with the default password 1main admin the Main Admin password is NOT editable Select the Operator Feature Page it...

Page 5: ...wn or hot keys There is a dedicated page for each of the hardware device types Series 5000 blue greenMachine green and yellobrik yellow Functions which all devices share are available as additional pa...

Page 6: ...her via an IP network The RCT 5023 G is the basic controller card and is all you need to connect a Series 5000 2RU rack frame to the LynxCentraal Control software The controller card has a LAN network...

Page 7: ...individual IP address The entire system is accessible under two different IP addresses NOTE The processing boards will continue to work even if the Primary SERVER is not available In the event of a se...

Page 8: ...for the current operator or servers which were filtered out by the current operator do not show up in this table Available Rack Controllers The available rack controllers table on the right lists all...

Page 9: ...to three control servers Each server can assign an individual name to the controller Options of Detaching a RCT 5023 Rack Controller from a Control SERVER 1 Select the RCT 5023 or RCT 1012 rack contro...

Page 10: ...e LYNX RackController or LYNX Server in the list and do one of the following 1 If the system is connected to a network and you have a DHCP server Activate the DHCP checkbox so that the LYNX Controller...

Page 11: ...default factory setting admin password is lynx admin Repeat the above steps 1 or 2 for all LYNX RackControllers and LYNX Servers which need to be connected to your network NOTE If your LYNX component...

Page 12: ...input is removed the GUI will update the appropriate status information immediately usually within 500 msec NOTE Any changes to the configuration of a card by mouse click in the GUI are communicated d...