LHPM POST MOUNTED HEATER CARE & USE/INSTALLATION
|
17
ASSEMBLY
...
continued
The switch assembly contains three colored leads that match the corresponding colors from the heater. Connect the
matching wire colors to each other with an appropriate length of wire. We recommend a minimum 18 AWG gauge
wire rated for outdoor use.
This wiring kit is provided with a 24 Volt AC supply
with a minimum 20 VA capacity. The wiring kit
provides one black lead for connection of the switch
to the transformer. Mount the transformer in a location
protected from the weather.
The diagram on page 18 is the
recommended control circuit
for operating this appliance.
Optional base cover available
separately.
STEP 7