background image

Care & use/installation

  

|

25

FINAL CHECKS

LeAk TeSTinG

Leak Test Procedure:

• Create a soapy solution of 1 part soap and 3 parts water. 
• Confirm that all control knobs are in the off position. 
• turn on the fuel supply. for natural gas, turn the valve 

handle 1/4 turn to align with the gas flow.  

• for l.p., turn the cylinder valve knob counter clockwise 

one full rotation. 

• apply the soap solution generously by paint brush or 

squirt bottle on all connections and fittings. 

• if bubbles appear to “grow” on any of the connections, 

you have a gas leak. immediately turn off the gas supply.

Fixing a Gas Leak:

• shut off the gas supply
• turn all grill controls to the “on” position to purge the grill 

of any gas build-up, then turn the controls back “off”. 

• Wash off the soapy solution with cold water and dry. 
• tighten the loose joint, or replace the faulty part with 

manufacturer-recommended replacement parts. 

• do not attempt to repair the l.p. cylinder valve if it is 

damaged. the only way to safely resolve a damaged 
cylinder is to replaCe it. 

• repeat the leak test to ensure that no leaks are present.

note: the prosear™ 2 does not have an air shutter.
• the appearance of the prosear™ 2 burner should be 

visually checked. the ceramic tiles should be uniformly 
red to orange in appearance. there should be no lifting, 
fluttering or lazy blue flames. some food particles will 
show as yellow flames but should burn off.

one LAST ThinG

finally, before leaving, check all the burners for proper 
operation. make sure the control knobs turn freely and 
completely through their full range.

imPorTAnT:

make sure the owner knows where the main gas supply 
shut off valve is located.

Finally, for safety and for proper use & care, you must 
leave this manual with the owner. make sure you advise 
them to keep it for future reference.

for technical assistance call:

Lynx Customer Care 
888-289-5969

to prevent fire or explosion hazard, do not 
smoke or allow any potential source of ignition 
(sparks, electrical arcing, etc) in the area while 
performing a leak test. leak tests should be con-
ducted outdoors only. never conduct a leak test 
using fire or flame.

danger!

Summary of Contents for ASADO L30AG

Page 1: ...ASADO Care use installation L30AG Built In and L30AGF Freestanding Models MAKE THE MOST OF YOUR ...

Page 2: ...used in one of the components of the IR burner as an agent known to the state of California to cause cancer If you smell gas 1 Shut off all gas supply lines to the grill 2 Extinguish any open flames 3 Carefully open the lid Remember it may be extremely hot 4 If odor continues keep everyone away from the grill and immediately call your gas supplier or your fire department 1 DO NOT store or use gaso...

Page 3: ... table trailers boats or any other moving installation Always have an ABC Fire Extinguisher accessible never attempt to extinguish a grease fire with water or other liquids Storing your grill Store your grill in a well ventilated area If stored indoors detach and leave L P cylinder outdoors in a well ventilated area away from heat and away from where children may tamper with it Keep any electrical...

Page 4: ...s important safety tips and great hints for better grilling You ll want to keep it handy for easy reference Also at Lynx we enjoy hearing from our customers We like to hear about your successes but also about any difficulties you are having Please feel free to contact us with any questions or problems or just to share a new recipe Please include the model number of your grill in your correspondenc...

Page 5: ...ss Checklist before each use for your safety 1 Before each use complete the checklist above 2 Remove the cover 3 Make sure all burner control knobs are in the OFF position 4 Push in the Power Shutoff button The blue LED lights above the knobs will indicate that the grill is energized 5 Turn the knob to the desired position The BLUE burner indicator light will glow when the burner is ON The BLUE bu...

Page 6: ...1 CONTACTING CUSTOMER CARE 12 THE LYNX STORY 12 lynx limited warranty 13 LYNX COMMON AREA LIMITED WARRANTY 14 before you start 16 if shipment arrives damaged 16 important notes 16 unpacking assembly 17 specifications installation 19 Built In Installations 19 Clearance to Combustible Materials 19 Gas connections 21 Natural Gas 21 LP Gas 22 gas line purging 23 gas conversion kits 23 electrical conne...

Page 7: ...ng the grill and risking personal injury If your grill has been unused for a long time inspect and clean the burners venturis valves and orifices See INDEX Cleaning the Brass Burner for further details 12 Never grill without the drip pan in place Always ensure that the drip pans are in place to prevent grease from leaking downward and producing a fire or explosion 13 Grease is extremely flammable ...

Page 8: ...until the grill reaches the tem perature set point The indicator lights and burners will cycle OFF and ON under normal operation to maintain the temperature setting SETTINGS Low 100 F Med Low 150 F Medium 225 F Med High 300 F High 375 F Maximum 450 F FOOD SETTING Eggs 325 F 350 F 160 C 180 C Bacon Breakfast Sausage 425 F 450 F 220 C 230 C Toasted Sandwiches 375 F 400 F 190 C 200 C Boneless Chicken...

Page 9: ... NEAR POOLS AND COASTAL AREAS The 304 stainless steel material used in the construction of a Lynx Grill is highly rust resistant however chlorine in the air from swimming pools or the salt from sea air may cause surface rust to appear and even create some pitting if left on the product Here are a few tips to avoid this Regularly wipe down the exterior surfaces with a damp cloth Micro fiber cloths ...

Page 10: ...t below before calling Lynx for service PROPER PLACEMENT OF EACH BURNER IS CRITICAL AFTER CLEANING THEY MUST BE CENTERED ON THE BRASS ORIFICE RESTING LEVEL WITHOUT ANY ROCKING FAILURE TO MEET THESE CONDITIONS MAY CAUSE A VERY DANGEROUS CONDITION THAT CAN CAUSE PERSONAL INJURY AND PROP ERTY DAMAGE WARNING SMELL OF GAS WHILE COOKING IF YOU SMELL GAS WHILE THE GRILL IS OPERATING IM MEDIATELY TURN OFF...

Page 11: ...nd free from obstructions LP Propane units Is the cylinder almost empty Almost empty cylinders may not have sufficient pressure to run the burners at high heat Have the line pressure checked by a qualified technician See INDEX Gas Requirements for further details Flow Limiting Device Improper lighting procedures may have activated the LP cylinder s flow control device reducing the heat output To r...

Page 12: ...engineers with over a centu ry of collective experience had a dream They dared to take their extensive commercial manufacturing know how and create a line of outdoor cooking products that offer com mercial elegance and performance to the consumer market Lynx has taken the quality workmanship service and innovation of the commer cial market and incor porated it into the Lynx Professional Grills lin...

Page 13: ...use of its grill products 4 Warranty shall not apply and Lynx is not responsible for damage resulting from misuse abuse alteration of or tampering with the appliance accident hostile environ ment flare up fires improper installation or installation not in accordance with the instructions contained in this manual or the local codes 5 Lynx shall not be liable for incidental consequential special or ...

Page 14: ...y to the original location of installa tion and may not be transferred 3 Warranty is in lieu of all other warranties expressed or implied and all other obligations or liabilities related to the sale or use of its grill products 4 Warranty shall not apply and Lynx is not responsible for damage resulting from misuse abuse alteration of or tampering with the appliance accident hostile environ ment fl...

Page 15: ...i 3 5 kPa WARNING 1 Always maintain the required clearances from combustible construction as detailed The grill is designed for outdoor use only Never use in a garage building shed breezeway or other enclosed area This grill shall not be used under any overhead combustible construction 2 Gas grills are not design certified for and are not to be installed in or on recreational vehicles portable tra...

Page 16: ...er locate the grill under a roof or overhang in a building garage shed or other such enclosed area Never locate the grill under combustible construction Installation must conform with local codes or in the absence of local codes with either the National Fuel Gas Code ANSI Z223 1 NFPA 54 Natural Gas and propane Installation Code CSA B149 1 or Propane Storage and Handling Code B149 2 in Canada BEFOR...

Page 17: ...afely and solidly on the crate during shipping The grill cannot be slid directly off of the pallet One way to safely move the grill off of the pallet is by lifting one end of the grill high enough to place a ramp under the wheel and then lift the other end while rolling the grill off of the pallet INTERIOR PACKING Lynx uses sturdy tie down cables and straps to ensure your grill arrives at your hom...

Page 18: ...aterials Minimum clearance from the sides and back of the grill to adjacent combustible construction below the top of unit are 12 from the sides and back Dégagement minimal entre les parois latérales et l arrière de l appariel et la construction combustible au dessous du panneau supérieur de l appareil 30 cm à partir des parois latérales et 30 cm à partir de l arrière Minimum clearance from sides ...

Page 19: ...8 25 19 00 LDR36 2 34 25 19 00 LDR42 1 40 25 19 00 LDR36T 31 63 19 00 LDR42T 37 63 19 00 Side burners MODEL A B C LSB1 12 13 10 63 24 50 LSB2 12 13 10 63 24 50 LSB2PC 24 25 10 63 24 50 LPB 19 00 10 63 22 00 Utility drawers MODEL A B C LUDE 12 13 19 25 24 00 LUDXL 17 25 18 57 24 25 LDW19 17 50 19 00 24 50 LMD 21 75 5 63 23 38 Warming drawers MODEL A B C L30WD 28 50 10 00 20 50 L42CC 40 25 19 38 24 ...

Page 20: ... 120V GFI outlet must be located within 6 of the 1 hole 1 2 NPT gas connection CLEARANCE 331 2 34 15 25 ICE MACHINE 3 2 Ø or 2 square holes for manifold connection rear or bottom access 12 min Grill Cocktail Pro Warming Drawer Convenience Center Utility Drawer Side Burner Drop In Cooler LDC18 Access Doors A B 21 4 31 2 31 4 min 2 3 min C Trash Center 363 8 min 31 2 81 4 181 4 61 4 181 4 Trash Chut...

Page 21: ...nform to local codes with the National Electrical Code ANSI Z223 1 NFPA 70 latest edition and the National Fuel Gas Code ANSI Z223 1 NFPA 54 in the U S and CGA B149 1 2 in Canada Canadian installations must conform to CGA B149 1 2 natural gas propane installation code Canada NATURAL GAS Lynx recommends that only qualified professionals perform the required plumbing on this product To ensure satisf...

Page 22: ...nders of the U S Department of Transportation DOT and designed for use with a Type 1 system only Cylinders of free standing grills must be secured using the provided cylinder retention system to avoid accidental movement When exchanging your cylinder for a refill ex change only for a Type 1 20lb cylinder with an over fill protection device Never use a cylinder with a damaged valve A dented or rust...

Page 23: ... conversion kits are available from Lynx Grills to allow the grill to operate on either Nautal gas or LPG These kits should be installed by a quaified technician The kits come with complete installation instructions These instructions should be read completely and fully under stood before installing the conversion kit BUILT IN INSTALLATION Shut off the gas supply at the main valve Disconnect all p...

Page 24: ... circuit with this outdoor cooking gas appliance Do not use this outdoor cooking appliance if it has been submerged under water without thorough inspection by a qualified technician This grill is equipped with a three prong grounding electric plug for your protection against shock hazard and must be plugged directly into a properly grounded three prong outlet Never cut or remove the grounding pron...

Page 25: ...only way to safely resolve a damaged cylinder is to REPLACE IT Repeat the leak test to ensure that no leaks are present NOTE The ProSear 2 does not have an air shutter The appearance of the ProSear 2 burner should be visually checked The ceramic tiles should be uniformly red to orange in appearance There should be no lifting fluttering or lazy blue flames Some food particles will show as yellow fl...

Page 26: ...26 Care use installation asado GRILL assembly EXPLODED VIEW 2 16 10 8 9 4 6 21 5 14 26 19 25 23 22 12 13 15 30 1 20 11 17 24 28 7 35 27 33 35 40 27 28 18 28 41 29 3 35 ...

Page 27: ... 33148 LIGHT SWITCH ASSY 1 21 34846 ROD KICKSTAND 1 22 34863 FITTING ADAP 3 8 TUBE TO 1 2 NPTF 1 23 31582 UNION COUPLER 1 2 NPT 1 24 13010 ELBOW PIPE FEM X MALE 1 2 NPT 90 DEG 1 25 32383 SCREW SHLDR 1 4 20 X 1 2 SHC SS 5 16 DIA X 1 4 2 26 32384 SCREW SHLDR 10 32 X 1 4 SLTD SS 1 4 DIA X 5 8 1 27 31930 SCREW 1 4 20 X 3 8 HHD SS 18 28 14014 SCREW 8 32 X 1 2 THP SS 9 29 14050 SCREW 10 24 X 3 8 PHP SS ...

Page 28: ...13 8 9 7 30 29 3 10 14 2 16 7 30 14 10 1 2 12 13 12 16 24 16 1 31 5 17 4 11 25 26 15 27 28 22 29 6 13 8 9 7 30 29 3 10 14 2 16 7 30 14 10 1 2 12 13 12 16 24 16 1 31 CONTROL PANEL EXPLODED VIEW CONTROL PANEL EXPLODED FRONT VIEW CONTROL PANEL EXPLODED BACK VIEW ...

Page 29: ...19 KNOB BURNER 2 15 32837 FLEX TUBE S S 3 8 X 24 1 16 70272 NEON LIGHT ASSY 2 17 70270 POWER 12VDC ASSY 1 18 70271 CABLE HARNESS HI VOLTAGE 1 19 70268 LOW POWER HARNESS ASSY 1 20 70276 LED HARNESS 30AG 1 21 70269 AC POWER HARNESS 1 22 34885 CLAMP CUSHION 3 8 HI TEMP 1 23 34867 CLAMP CUSHION 1 2 HI TEMP 2 24 L14018 SCREW 6 32 X 1 4 PHP SS 4 25 33706 SCREW 10 32 X 3 8 PHP SS 4 26 14030 SCREW 1 4 20 ...

Page 30: ...E EXPLODED VIEW 5 1 4 3 2 1 70255 GRIDDLE PLATE WELDMENT 30 1 2 34812 PLATE HEAT TRANSFER ASADO 2 3 34811 PLATE HEAT COLLECTOR 2 4 14044 WASHER 1 4 FLT SS 11 16 O D 16 5 20083 NUT 10 24 HEX SS MACHINE 16 ITEM NO PART NUMBER DESCRIPTION QTY ...

Page 31: ...Care use installation 31 Asado GRILL WIRING SCHEMATICS ...

Page 32: ...Lynx Professional Grills 7300 Flores Street Downey CA 90242 Service 888 Buy Lynx 888 289 5969 Fax 562 299 6789 www lynxgrills com ...

Reviews: