2.03     Part Guard Arming Option 1 

PART GUARD means that the system is only armed in pre-set zones, allowing you to oc-
cupy or pass through the unarmed zones. This is normally used for night-time setting of the 
alarm system to isolate the bedrooms.  

Enter a Valid User Code and press SET within 

3

 seconds. 

 
Example:  

Enter:  

System Ready   

Melcom

 

         

     ? 

     ? 

     ? 

     ? 

Part Arming   

 

         

System Armed   

 

PART GUARD mode will become armed within 5 seconds (or 
the time programmed by the engineer). You should leave or go 
to a non-armed part of the building, zone LEDs, PA and Tam-
per  will flash momentarily to indicate Part Guard Arming. 

Note: If you have zones programmed as Sleep Watch zones, these can only be 
armed after Part Guard arming and pressing the sleep button on the sleep watch  
remote keypad.  

2.04     Omitting Zones Full Guard  

You might wish to omit zones in full guard before arming the system. For example, you can 
omit the zone that protects the garage.

 

   SET 

Enter a valid user code and press OMIT, enter zone number to be omitted and press 
OMIT. 

Enter:        1 

     ? 

     ? 

     ? 

     ? 

Press:   OMIT 

     2 

Press:   OMIT 

System Arming   

 

Omit Zones   

System Arming   

 

Zones omitted will be reintroduced to the system once the system has been disarmed. If 
you wish to have a zone disabled from the system, you must contact your installation        
engineer. 

  

Note: PA, Tamper, Fire Zones & 24 Hour Zones can not be omitted.

 

Example: Omitting zone 2 

Summary of Contents for LY69-010-68

Page 1: ...Keypad Disarming System After Activation Arming Disarming Part Guard Option 2 Arming and Disarming Sleep Watch Zones Activating Sleep Watch Panic Button Silencing Panic Alarm Activation Memory Recall...

Page 2: ...ed with intrusion detectors to the control panel will detect any unauthorised entry and set off the internal and external alarm Make sure all zones and P A Panic Alarm loops are closed The control pan...

Page 3: ...art Guard Arming Note If you have zones programmed as Sleep Watch zones these can only be armed after Part Guard arming and pressing the sleep button on the sleep watch remote keypad 2 04 Omitting Zon...

Page 4: ...r installation engi neer Note PA Tamper Fire Zones 24 Hour Zones can not be omitted System Arming Press OMIT 6 Press OMIT SET Omit Zones 6 Part Arming 2 06 Activating Resetting Keypad Panic If the con...

Page 5: ...is will activate the en try tone for length of ENTRY time as programmed by your installation engineer Enter a valid user code to disarm the system and press RESET Example disarming system after zone 3...

Page 6: ...throom or kitchen at night If a Sleep Watch zone is activated it will not activate the alarm immediately but give a timed delay to enable you to enter your user code into the system keypad The sleep w...

Page 7: ...e unit If you do not reset the panic button the alarm system will not function until the panic button is reset and the reset key on the keypad 2 13 Memory Recall The control panel can recall the last...

Page 8: ...tically reset The alarm will activate once more should another zone be acti vated or if the zone that originally activated is closed Upon entering the premises the strobe will be flashing to indicate...

Page 9: ...u do not forget this code as no programming changes can be made in ei ther user or engineer programming without entering this code Press 8 Zone 1 4 LEDs illuminate Enter New Code Master Enter a new 4...

Page 10: ...activated after the system has been disarmed by user code 6 internal sirens will sound only User code 6 can silence the alarm and arm the system again but can not reset the secure zones Upon enter use...

Page 11: ...d Enter zone numbers to set as chime zones zone LED will flash if set as chime zone Tog gle corresponding zone key number to enable or disable chime zones Chime Zone None Example Programming zone 1 as...

Page 12: ...System Test Volume Low System Test Zone Test System Test External Siren System Test Press Press Press Press Press Press Press 1 3 2 4 5 0 RESET Tests strobe Tests external siren Tests high volume int...

Page 13: ...r Press OMIT SET Omit LED illuminates Full Guard Disarming Enter User Code Day LED illuminates Part Guard Disarming Option 1 Enter User Code Day LED illuminates Part Guard Disarming Option 2 Sleep Wat...

Page 14: ...made to provide accurate information however slight variations can occur We reserve the right to make changes for product improvement at anytime Function Factory Settings User Settings Master User Co...

Page 15: ...lashing System Requires Service call in staller Tamper LED Illuminated In Day Mode Tamper LED illu minated Tamper Fault Call installer PA LED Illuminated Can Not Arm System Panic button not reset also...

Reviews: