background image

 

 

9

Chapter 2 Conference Main Unit 

 

2.1 Conference Main Units 
 

The  Conference  Main  Unit  forms  the  core  of  the  entire  conference  system.  It  provides  power  supply  to  all 
contribution unit and serves as key component to link system hardware to software control. The CMU adopt 
DSP techniques such as feedback suppression, noise cancellation, automatic gain, and digital equalization. 
It’s flexible and reliable for any conference of mini/medium/large meeting.  

 
Product Include:

 

 

H-9500M 
 

Fully  Digital  Conference  System  Main  Unit  (Discuss,  recording, video  tracking, voting, monitoring,  4.3  inch 
TFT touch display, Ethernet interface) 
 

H-9500E 
 

Fully Digital Conference System Extension Unit 
 

2.1.1 Main Features and Specifications of CMU 
 

a) FTP  Cat6  cables  are  introduced  for  data  transmission  and  power  supply,  supporting  message 
transmission  with  a  fast  internet  service  100M.  Thus,  audio  signals  could  be  delivered  perfectly  in  a  long 
distance. 
b) A sampling frequency of 48kHZ is supported by the system. 
c) In order to ensure a clear, highly sensitive, and perfect sound quality, CMU built-in high-performance dual-
core  CPU,  32  bit  high-speed  DSP  technologies,  feedback  suppression,  noise  cancellation,  automatic  gain, 
and digital equalization are all available. 
d) TCP (transmission control protocol) and IP (internet protocol) are all available, enabling a reliable and safe 
management. 
e) Built-in video  tracking  control  and  ballot  processor,  high  definition  switching matrix  are  available for  auto 
video tracking with HD video matrix. 
f) The CMU owns a built-in USB, allowing the realizing of recording and monitoring. 
g) Audio could be outputted in balanced or unbalanced way. 
h) Different kinds of interfaces, like, Ethernet, RS422 and RS232, could meet requirements towards different 
devices. 
i) Three modes are available, including REQUEST(1-4),LIMIT (1-4), and FIFO (1-4). They all support speech 
timing function. 
j) Multiple conference functions could be realized when CMU is connected to computer. 
k) Power Input: 230VAC 50/60Hz 
l) Static Power: 12W 
m) Maximum Output Power: 300W 
n) Frequency Response: 20Hz-20KHz 
o) S/N: > 80dB 
p) T.H.D: <0.05% 
q) Dimensions: 484x 88 x 360 mm, 2 U rack 19” 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for H-9200 Series

Page 1: ...Installation and Operating Manual Fully Digital Conference system H 9500 Series 2018 V3 ...

Page 2: ...s a part of the product it must accompany it at all times and it needs to be delivered to the new user when this product is sold In this way the new owner will be aware of all the installation operating and safety instructions Heed all warnings All warnings on the product and in owner s manual should be adhered to Heed all warnings Follow all instructions All operating and user s instructions must...

Page 3: ...enings Safe power line use Hold the plug and the wall outlet firmly while disconnecting the unit from AC power When the unit will not be used for a long period of time please unplug the power cord from AC power outlet To avoid power cable damage don t strain the AC power cable and don t bundle it In order to avoid damage to the unit s power cable be sure that the power cable is not walked on or pi...

Page 4: ...ot defeat the grounding connection Grounding is for user safety Use only connectors and accessories suggested by the manufacturer This unit should be fitted in an equipment rack see INSTALLATION and kept far from Wet places Direct exposure to heat sources like sun light Improperly ventilated places Disconnect the power cord during storms or when the unit is not in use In order to prevent fire and ...

Page 5: ...ries fully digital conference system Chapter 3 Conference unit Descriptions in detail of the functions and indications installation and connection configuration and operation of conference units of H 9500 series fully digital conference system Chapter 4 Conference system connection Descriptions in detail of the connection between system devices Chapter 5 Software control Descriptions in detail of ...

Page 6: ... 9500E Fully Digital Conference System Extension Unit Conference Microphone Units H 9200 series H 9200c Fully Digital Conference System Chairman Unit H 9200d Fully Digital Conference System Delegate Unit H 9510c Fully Digital Conference System Chairman Unit H 9510d Fully Digital Conference System Delegate Unit Accessories H CT6 FTP CAT6 H ZD01 Terminal unit H EP110 Single Earphone H EP110H Headpho...

Page 7: ...l Conference System This system consists of one or more of the following items Conference Main Units H 9500M Fully Digital Conference System Main Unit Discuss recording video tracking voting monitoring 4 3 inch TFT touch display Ethernet interface H 9500E Fully Digital Conference System Extension Unit Conference Microphone Units H 9200 series H 9200c Fully Digital Conference System Chairman Unit 2...

Page 8: ...es do in no case exceed the maximum possible value delivered by each Ethernet interface Otherwise the system will not work properly or automatic protection will be triggered The last mic of each Ethernet outputs must connect one terminal unit 1 2 3 Accessories Relevant accessories connected or used in H 9500 series include connection cables terminal units software etc 1 3 Conference Management Sof...

Page 9: ...rophone functions such as speaking sign in ballot rights d Speaking time and warning time limit e Predefined position setting video tracking support Pelco D and Visca maximum 8 cameras can be controlled f Edit conference data such as conference heading proposal sub secreen display delegates data ballot information g System line detection to check microphone status 1 4 4 Conference recording a USB ...

Page 10: ...orted by the system c In order to ensure a clear highly sensitive and perfect sound quality CMU built in high performance dual core CPU 32 bit high speed DSP technologies feedback suppression noise cancellation automatic gain and digital equalization are all available d TCP transmission control protocol and IP internet protocol are all available enabling a reliable and safe management e Built in v...

Page 11: ... LAN Ethernet interface for communication between the CMU and the PC 13 ALARM Emergency signal interface for connection to public emergency system 14 Delegates 4 path microphones output interface Ethernet to connect system microphones 15 Extend Dual connection Ethernet interface to the extension main unit 16 Output Balanced signal output male XLR3 Connect mixer or amplifier to this output 17 Recor...

Page 12: ...MU The display will light after turn on the main unit with power switch and enter main interface as below Instruction of TFT touch display menu The display include 2 menu interface user can select it with and to switch the menu Figure 4 a Active microphone number Menu A To display real time active microphone number in the system b Time Limit Menu A Figure 5 RS 422 1 TXD RS485 2 TXD RS485 3 RXD 4 R...

Page 13: ... intervene until the number of active delegate microphones again falls below this limit FIFO mode 1 4 When this mode is selected First In First Out the display will display FIFO MODE plus the number of delegates who can speak simultaneously In this mode the keeps track of the order in which the delegate microphones are activated Once the preset limit of simultaneous delegates has been reached and ...

Page 14: ...to track and voting function user can set the microphone id after setup the system This coding information is displayed on all the microphone LCD press the on off button of the corresponding mic to the affected the number The other mics are always show the coding information but with an incremented number of a unit Please make sure the microphone id number should be different in one system Please ...

Page 15: ...erface cable connectors for microphones figure 1 ref 14 When connecting the main unit to the microphone units just connect the RJ45 connector of the first unit to the output of the main unit For longer distance between the microphone unit and CMU Extension Unit a FTP cat6 cable both end of this cable equipped with RJ45 connector is used Just connect the RJ45 connector of the cable to the microphon...

Page 16: ... Instructions POWER Main power on off switch Power light System outlet Ethernet interface to connect microphones A B C D Extension input output A B Connecting to CMU or next H 9500E extension unit AC POWER SOCKET Power 230VAC 50Hz 2 2 2 Connection to the CMU and microphones ...

Page 17: ...onitoring Speaker Ethernet interface H 9510d Fully Digital Conference System Delegate Unit 2 4 inch IPS Display Monitoring Speaker Ethernet interface 3 2 Functions and instructions Option 1 Short Gooseneck Mic H 9200c d Option 2 Long Gooseneck Mic H 9510c d Electret condenser cardioid microphone Indicator light on active microphone When microphone is active indicator light switches on Gooseneck mi...

Page 18: ...pressing this key will clear the request list If chairman microphone is not active pressing this key will activate it 2 4 inch IPS To display the microphone status and other information Microphone socket to fix the gooseneck microphone Ethernet interface both Ethernet interface has same function user can connect RJ45 connector to any Ethernet interface if necessary Microphone speaker monitor Earph...

Page 19: ...nes are connected properly to the CMU All conference microphones must be coding when the system is used for the first time or when adding or replacing conference microphones The coding number can be activated by the menu operation on the CMU TFT touch panel After selecting Auto coding from the CMU TFT touch panel Auto coding and the coding number will be displayed on the IPS display and all the LE...

Page 20: ... 2 3 4 reached If the microphone on off key is pressed its microphone will be activated and the first activated microphone will be deactivated at the same time to maintain the active microphone number limitation If the number of activated microphone include chairman microphone reaches 5 turning on another microphone will switch off the delegate microphone turned on first Request mode Request to sp...

Page 21: ...de on the main unit is configured as Mic Mute all active delegate microphones will be muted temporarily when this key is pressed and they will restore when pressed the on off key to release this mode If t configured as Mic Off all active delegate microphones will be turned off and the request to speak list will be purged when this key is pressed 2 Speaking The chairman microphone is unlimited by t...

Page 22: ... chain connected FTP Cat6 cable can be used between microphone units and the CMU The last microphone unit of each Ethernet outputs must connect one terminal unit 4 1 3 Extension cable If the distance between the CMU and the microphone unit or one microphone unit to another one exceeds 2 meter an extension cable is needed Due to the voltage drop in the extension cable caused by the ohmic resistance...

Page 23: ...g system will automatically find the appropriate preset and focus on the speaker The view of the speaker will be display on large screen or other display devices The automatic video tracking system is compatible with several kinds of video signals and operates automatic video switching The video tracking system is composed of video switcher button board and high speed dome camera Use RS485 cable a...

Page 24: ...en and controlling various electric devices such as DVD DVR TV projector etc RS232C or RS485 interfaces are available Remote controlling even from distant places can be achieved through LAN or internet The H 5200 central control system and H 9500 series conference system can be joined together seamlessly In addition to standard functions of a normal central touch panel control system it can also c...

Page 25: ...ernet interface LAN to the operation computer 5 1 Login Copy the software to computer the default password is 1234 the password can be changed after login The login interface is shown in the following figure Input the password and then click the Login the software will start searching the CMU with the preset IP address and loading initial data If system cannot search the CMU or there has some conn...

Page 26: ...t Conference Conference Management Video Setting Line Detect and System Setting 5 2 Operation 5 2 1 System Setting Clicking System Setting to enter system setting interface there are four sub menu in this part Change Password Conference Mode Sub Screen Others Change Password Input the Current Password New Password and Password Confirm then click the OK button to change the password ...

Page 27: ...tion Limit time 1 60 minutes and warning time 1 60 seconds When set time limit by software the limit time will not show on microphone display when microphone is on only Sub screen display the limit time Sub Screen You can select the resolution of sub screen projector TV LCD display Please restart the software after change the resolution ...

Page 28: ...ay panel 5 2 2 Preparation Clicking Preparation to enter system setting interface there are four sub menus in this part Conference Heading Proposal Edit Delegate Data Sub Screen Conference Heading You can create delete modify a conference heading in this interface the created conference heading will display in the bottom right corner according to the sub screen setting ...

Page 29: ... can create delete delete all modify the proposals and the created conference proposal will display in the bottom right corner according to the sub screen setting Delegate Data You can create and edit delegate data of the selected conference heading The Delegate name can be displayed under microphone icon in conference control interface ...

Page 30: ...when prepare the meeting Save all delegate data to computer in xls format Load update delegate s photo photo must in bmp format To modify the selected delegate data Sub Screen Operator can set edit display template for Conference Heading Conference Proposal Last speaking Name Current Speaking Name Request Name the Sub screen will display the Corresponding information according to the setting Text ...

Page 31: ... can add chairman delegate mic icon for the conference and adjust the layout in the software operator also can change the chairman delegate status icon by himself All setting edit must after clicking Adjust Layout Add Chairman Delegate Operator can add the chairman and delegate microphone icon for the conference ...

Page 32: ...ans that microphone has data communication problem Chairman ID will display in the line detect results 5 2 4 Video Setting The software control can set camera presets for every conference microphone If the conference microphone is switched on video tracking system will automatically find the appropriate preset and focus on the speaker The view of the speaker will be display on large screen or othe...

Page 33: ... to set the preset position for other microphones Video Home If operator wants to setup video Home function please select the proper camera to get the best image and then click PA button to save the data to CMU Video Home is the image on the display screen when all microphone off The camera only tracking the last turned on microphone if the last turned on microphone is off camera will track the pr...

Page 34: ...est list Conference Mode All details of the conference mode will be displayed on the top right corner of the software operator can change and reset the mode by Set Button Request List If set the conference with request mode the request microphone id and request participators name will display in the request list operator can permit or refuse the request ...

Page 35: ...cessary Sub screen Info Operator can set and choose the speaking request name displayed on the sub screen Microphone control Please choose the microphone icons the icon will display the microphone id and participators name on the left part of the software or input the microphone id in the text box operator can turn on turn off Forbid on Release the microphone by the control button The icons will d...

Page 36: ...ited Mic Green Flash Request On Green Flash Autocoding Red Flash 3 Metal stem with gooseneck to adjust angle and direction freely Foam windshield For gooseneck option 1 For gooseneck option 2 6 2 Terminal unit H ZD01 The terminal unit must connect to the last microphone of each output path 6 3 Accessories FTP Cat6 Ethernet cable is involved in the connection of conference system devices Eleven typ...

Page 37: ...36 6 4 Earphones The jack plug of the stereo headphone can be inserted into an Φ 3 5mm stereo headphone jack socket Applicable types include H EP110 Single earphone H EP110H headphone ...

Page 38: ...could cover them and thus prevent proper cooling of electronic components inside the units By falling into a unit objects could cause trouble such as fired and electric shock To avoid the risk of shock or permanent damage to the system unit do not expose units to rain or moisture Do not attempt to remove the top cover of the system main units as you will be exposed to a shock hazard The covers sho...

Page 39: ...ations and flicker Compliant with EN 61000 3 3 8 2 Conference System main unit 8 2 1 Main unit 8 2 1 1 Physical characteristics Conference system main unit H 9500M Installation Standard 19 rack Dimensions mm Color Black Weight 7 6 kg 8 2 1 2 Electrical characteristics Conference system main unit H 9500M Microphone capacity 320 Frequency response 20Hz 20KHz SNR 80dB T H D 0 05 Mains power supply 23...

Page 40: ...ics Conference system main unit H 9500E Mains power supply 230V AC 50 60Hz Output Voltage 24VDC Maximum power consumption 300W Connection FTP Cat6 Ethernet cable Connector RJ45 Ethernet 8 3 Conference System main unit 8 3 1 H 9200 9510 series conference unit 8 3 1 1 Physical characteristics Conference system main unit H 9200 series Installation Tabletop Dimensions mm Color Black Weight 0 65 kg ...

Page 41: ...one Sensitivity 44dB 2dB Max power consumption H 9200 Series 2 2W H 9510 Series 2 5W Directivity 20dB 1 kHz Equivalent noise 20 dBA SPL Max SPL 125dB THD 3 Gooseneck Length Option 1 30 cm Option 2 42 cm 8 4 Earphone H EP110 single earphone Cooperates with the IR receiver or the conference unit Hi Hi sound quality 32 Ohm 10 Φ 3 5mm stereo jack Frequency response 20Hz 20KHz Nominal Input Power 20mW ...

Page 42: ...0Hz 20KHz Nominal Input Power 20mW 1KHz at 0 8V Max Input Power 60mW Distortion Within 5 5mW 1KHz Sensitivity 111dB 3dB 0 179V at 1KHz 5mW 8 5 System connection Mains cables Blue Neutral Brown Hot Phase Green Yellow Earth Ground Type of connections Balanced connection Balanced connection with TRS jack Unbalanced connection with TRS jack RCA Connection ...

Page 43: ...ng No 26 Jinlong Road Nansha District Guangzhou China 511458 Tel 86 20 39390663 Fax 86 20 39390669 www lyintlcorp com We maintains a policy of constant research and development therefore we reserve the right to apply improvements to existing equipment without prior notice ...

Reviews: