  Warning 

 

 

In order to prevent the personal injury to user and other persons, the damage to equipment or loss of assets, 

please abide by the following basic precautions: 

                This mark indicates what is prohibited.                This mark indicates what must be done.   

 

Check  the  power  line  for  damage;  please  do  not 

unplug  by  pulling  the  power  cord  but  unplug 

directly;  otherwise,  it  will  lead  to  electric  shock, 

short circuit or fire. 

 
 

 

During the process of use, do not block the vent. It is 

required  to  keep  all  the  vents  unblocked  in  order  to 

prevent the overheating.   

 

 

 

 

 

Please  do  not  put  this  equipment  in  the 

heavily  dusty,  shocking,  extremely  cold,  or 

hot environment 

 

 

 

 

Please  do  not  put  any  weight  on  this  equipment.  Do 

not  operate  switch  and  button  or  connect  the  external 

audio source equipment with overexertion.   

 

 

Prevent  the  entry  of  any  foreign  matter  (e.g. 

paper  and  metal)  through  the  clearance  or  opening 

of  the  equipment  into  it;  in  such  case,  please 

disconnect the power supply immediately.   

Do  not  try  to  remove  any  component  in  the 

equipment or transform it in any way.   

 

In  case  of  the  sudden  interruption,  or  abnormal 

smell,  or  smoking  during  the  operation  of  the 

machine, please unplug the power supply to prevent 

the electric shock, fire and  other accidents, and ask 

the professionals to repair the equipment.   

                                             

 

 

Smell of scorching

 

Please  make  sure  to  unplug  the  AC  power  line  or 

switch  off  the  socket  on  the  wall  to  achieve  the  zero 

energy consumption if this equipment is out of service 

for a long term.     

 

 

 

 

Summary of Contents for CM12

Page 1: ...M12 Operation Instructions Welcome to use our public address system For the better application of this equipment please read the operation instruction carefully prior to use LY Inter na ti ona l E lec troni cs C o L td http www lyintlcorp com ...

Page 2: ... use instruction to connection of system and instruction to operation of product and so on The user shall read this operation instruction carefully prior to connection installation and use and shall operate in accordance with the instructions herein The attention must be paid to the instructions with such identification on the back panel of the machine Please use or operation the machine following...

Page 3: ...t Please do not put any weight on this equipment Do not operate switch and button or connect the external audio source equipment with overexertion Prevent the entry of any foreign matter e g paper and metal through the clearance or opening of the equipment into it in such case please disconnect the power supply immediately Do not try to remove any component in the equipment or transform it in any ...

Page 4: ...ODUCT 1 1 1DESCRIPTION OF EQUIPMENT 1 1 2PERFORMANCE CHARACTERISTICS 1 II DESCRIPTION OFAPPEARANCE 2 2 1DESCRIPTION OF FRONT PANEL 2 2 2DESCRIPTION OF REAR PANEL 3 III INSTRUCTION TO CONNECTION 4 PACKING LIST 6 PERFORMANCE SPECIFICATION 7 ...

Page 5: ...ely or to switch on and off any partition on the one key basis showing a high extent of humanization The multistage expansion is supported 1 2 Performance Characteristics Level indication Up to ten partitions under control Two built in bell signals Adjustable volume of microphone and bell Gooseneck microphone in specification of CM10 RJ45 socket is used for connection between microphones and casca...

Page 6: ...alight 8 CHIME 2 switching key When pressing CHIME 2 key 6 to select the bell 2 this lamp will be alight 9 Key ALL ON for one key switching on of partitions Press this key to switch on all the partitions and the corresponding indicator lamp 10 will be alight 10 Indicator lamp for one key switching on partitions Press ALL ON key 9 to switch on all the partitions when the indicator lamps indicating ...

Page 7: ...face IN and OUT a The OUT interface of CM12 paging microphone is used to access the CALL STATION interface of PM912 power amplifier b Cascade mode The OUT interface of the previous CM12 microphone is used to connect the IN interface of the next CM12 microphone and the OUT interface of the next CM12 microphone is used to connect the IN interface of the followed CM12 microphone and so on or the OUT ...

Page 8: ...OPEN CAUTION PM906 F4AL250V F6AL250V PM912 F A 16V 22V 4 16 FUSE TYPE Nur Sicherung 250V Use Only Wi th A 250V Fus e Employ er Unlquem ent Avec Fusible De 250V 1 2 3 4 O N PM912 rear panel CM12 rear panel MIN MAX MIC VOL CHIME VOL MIN MAX OUT IN REMOTE OUTPUT F0 2AL 220V 50Hz 5W RISKOFELECTRICSHO CK DO NOT O PEN CAUTION POWER MIN MAX MIC VOL CHIME VOL MIN MAX OUT IN REMOTE OUTPUT F0 2AL 220V 50Hz ...

Page 9: ...in the equipment the non professional person shall not disassemble the housing for repair without the approval in order to prevent accident or aggravate the damage to the equipment Do not put any corrosive chemicals nearby or on the equipment 2 Precautions for after sales service In case of the installation and operation according to this instruction the company will provide the free warranty serv...

Page 10: ... LY Paging Microphone 6 Packing List No List Quantity 1 CM12 equipment 1 set 2 Warranty card 1 copy 3 Certificate 1 copy 4 Operation instructions 1 copy 5 3000MM network cable SY535 1 piece ...

Page 11: ...t if this equipment is not in service This equipment shall not suffer from water dripping or spraying Do not place the vase full of water onto the equipment Do not open the cover plate of the machine without authorization to prevent electric shock The repair shall be conducted by the professional with professional certificate if necessary The terminal marked with in the equipment indicates the haz...