background image

SOME PARTS OF THIS PRODUCT CAN BECOME VERY HOT AND MAY CAUSE 

BURNS. PARTICULAR CARE SHOULD BE TAKEN WHEN CHILDREN OR 

VULNERABLE PEOPLE ARE IN THE VICINITY. 

IN ORDER TO AVOID OVERHEATING, DO NOT COVER OR PLACE CLOTHES 

DIRECTLY ON THE RADIATOR.

WASTE DISPOSAL ACCORDING TO THE WEEE DIRECTIVE (2002/96/EC). THE SYMBOL 
ON THE PRODUCT LABEL INDICATES THAT THE PRODUCT MAY NOT BE HANDLED AS 
DOMESTIC WASTE, BUT MUST BE SORTED SEPARATELY. WHEN IT REACHES THE END OF 
ITS USEFUL LIFE, IT SHALL BE RETURNED TO A COLLECTION FACILITY FOR ELECTRICAL 
AND ELECTRONIC PRODUCTS. BY RETURNING THE PRODUCT, YOU WILL HELP TO 
PREVENT POSSIBLE NEGATIVE EFFECTS ON THE ENVIRONMENT AND HEALTH TO WHICH 
THE PRODUCT CAN CONTRIBUTE IF IT IS DISPOSED OF AS ORDINARY DOMESTIC WASTE. 
FOR INFORMATION ABOUT RECYCLING AND COLLECTION FACILITIES, YOU SHOULD 
CONTACT YOUR LOCAL AUTHORITY/MUNICIPALITY OR REFUSE COLLECTION SERVICE 
OR THE BUSINESS FROM WHICH YOU PURCHASED THE PRODUCT.  APPLICABLE TO 
COUNTRIES WHERE THIS DIRECTIVE HAS BEEN ADOPTED.

GB

 

CAUTION

GB

 

 

WASTE DISPOSAL ACCORDING TO THE 
WEEE DIRECTIVE (2002/96/EC)

Due to the safety standard EN 60335, the text 
below is obligatory for all electric products, not 
only radiators.

This appliance can be used by children aged from 
8 years and above and persons with reduced 
physical, sensory or mental capabilities or lack 
of experience and knowledge if they have been 
given supervision or instruction concerning use of 
the appliance in a safe way and understand the 
hazards involved. Children shall not play with the 
appliance. Cleaning and user maintenance shall 
not be made by children unless they are older than 
8 and supervised. Keep the appliance and its cord 
out of reach of children aged less than 8 years.

Children of less than 3 years should be kept away 
from the unit unless continuously supervised. 
Children aged from 3 years and less than 8 years 
shall only switch on/off the appliance provided 
that it has been placed or installed in its normal 
operating position and they have been given 
supervision or instruction concerning use of 
the appliance in a safe way and understand the 
hazards involved. Children aged from 3 years and 
less than 8 years shall not plug in, regulate and 
clean the appliance or perform user maintenance.

GB

 

SAFETY 

INFORMATION

KAB

A I

NS

TALLA

TION AN

D OPER

AT

ING M

AN

U

AL

01/07/2018

GB

      

SAFETY

INFORMATION

  | 

6

Summary of Contents for KABA C

Page 1: ...KABA INSTALLATION AND OPERATING MANUAL A NEW GENERATION THAT TURNS EVOLUTION INTO A REVOLUTION CLASS I 230V 400V 50 HZ ...

Page 2: ...S Zone 0 3m 2 25m 0 6m 0 6m A C B A H B C 46 373 A 100 150 100 150 46 173 H mm mm mm mm 300 500 A C B A H B C 46 373 A 100 150 100 150 46 173 H mm mm mm mm 300 500 Min 100mm Min 100mm Min 100mm Min 200mm Min 100mm KABA INSTALLATION AND OPERATING MANUAL 01 07 2018 ...

Page 3: ...3 PRODUCT INFORMATION 3C 3D CLICK 3mm CLICK 3B KABA INSTALLATION AND OPERATING MANUAL 01 07 2018 KABA P 230V PRODUCT ONLY ...

Page 4: ...NO PRODUCT INFORMATION 4 4 5A 5B LED 1 LED 2 B A KABA INSTALLATION AND OPERATING MANUAL 01 07 2018 ...

Page 5: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 6 24 0h 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 7 24 P5 0h 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 1 24 0h 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 2 24 0h 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 3 24 0h 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 ...

Page 6: ...96 EC Due to the safety standard EN 60335 the text below is obligatory for all electric products not only radiators This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the ...

Page 7: ...ng the fixing method used to secure the radiator to the wall the type and condition of the wall itself and any additional potential forces or weights prior to finalising installation The fixing materials provided are only intended for installation on walls made of solid wood bricks concrete or on timber frame stud walls where the fixing is into the timber All walls being considered should have no ...

Page 8: ... HOWTO CREATE AND INITIATE A USER DEFINED HEATING PROGRAM ATTENTION When rotating dial B to access any of these features a pause of 0 5 seconds must be made at each position This is to give the thermostat enough time to detect the dial position 25 30 20 15 10 Auto 25 30 20 15 10 Auto K 01 25 30 20 15 10 Auto K 02 25 30 20 15 10 Auto K 03 25 30 20 15 10 Auto 25 30 20 15 10 Auto K 04 U1 P1 P2 P4 P5 ...

Page 9: ... 7 seconds to confirm LED 2 will change to solid green for 1 second to indicate that the value has been stored The heating program is now running 30 20 15 10 Auto K 06 25 30 20 15 10 Auto K 07 Rotate dial B to Auto LED 1 and LED 2 will continue to flash as described in the table below Comfort Mode Reduced Mode Heating Not Heating Heating Not Heating LED 1 5s On 1s Off 1s On 5s Off Off Off LED 2 Of...

Page 10: ... red rapidly for 7 seconds During this time the Comfort set temperature can be selected by rotating dial B to the desired temperature value and then wait 7 seconds to confirm LED 1 will change to solid red for 1 second to indicate that the value has been stored 25 30 20 15 10 Auto K 05 25 30 20 15 10 Auto K 06 25 30 20 15 10 Auto K 07 LED 2 will then flash green rapidly for 7 seconds During this t...

Page 11: ...ly for 7 seconds During this time the Comfort set temperature can be selected by rotating dial B to the desired temperature value and then wait 7 seconds to confirm LED 1 will change to solid red for 1 second to indicate that the value has been stored The thermostat will then return to normal operation Rotate dial B to Auto ADJUSTING REDUCED MODE SET TEMPERATURE 25 30 20 15 10 Auto 25 30 20 15 10 ...

Page 12: ...y function when the radiator follows a heating program OPEN WINDOW DETECTION This function will switch the radiator from any active mode to Frost Protection mode when an open window is detected room temperature drops by more than 2 C in less than 10 minutes LED 1 and LED 2 will flash twice every 6 seconds when Frost Protection mode is active NOTE Normal operation will resume if there is any user i...

Page 13: ...st the time setting Follow the procedure HOW TO SELECT AND INITIATE HEATING PROGRAMS FACTORY RESET The user defined program and set point temperatures can be reset to factory default settings To perform a factory reset follow the below steps 25 30 20 15 10 Auto 25 30 20 15 10 Auto x5 25 30 20 15 10 Auto Rotate dial B to Auto then to then back to Auto Repeat this sequence 5 times Auto Auto Auto Aut...

Page 14: ...o 70 C SETTING TEMPERATURE RANGE Comfort mode Frost protection mode 5 C to 30 C 7 C ELECTRICAL INSULATION Class I ELECTRICAL PROTECTION IP44 POWER SUPPLY 230 VAC 50 Hz or 400 VAC 50 Hz according to the product rating label DIRECTIVES STANDARDS The product has been designed to comply with the following Directives and Standards EN 60730 1 EN 60335 1 EN 60335 2 30 EN 62233 EN 55014 1 EN 55014 2 EN 61...

Page 15: ...A manual heat charge control with room and or outdoor temperature feedback N A electronic heat charge control with room and or outdoor temperature feedback N A fan assisted heat output N A Type of heat output room temperature control single stage heat output and no room temperature control no two or more manual stages no room temperature control no with mechanic thermostat room temperature control...

Page 16: ...LVI_KABA_2018 07 01 ...

Reviews: