LED 1 will start to flash red for 7 seconds. The quantity 
of flashes correspond function being enabled or 
disabled, as described below:-

1 flash  =  Adaptive Start disabled 
2 flashes  =  Adaptive Start enabled

•  

To enable or disable the Adaptive Start function, rotate 
dial B to either   or

 Auto

, and then back to  .

                        =  Disable Adaptive Start 
             

Auto

         =  Enable Adaptive Start

•  

LED 1 will flash as described above.

•  

Wait 7 seconds to confirm.

•  

LED 2 will start to flash green for 7 seconds. The 
quantity of flashes corresponds to the Open Window 
Detection function being enabled or disabled, as 
described below:-

1 flash  =  Open Window Detection disabled 
2 flashes  =  Open Window Detection enabled

•  

To enable or disable the Open Window Detection 
function, rotate dial B to either    or

 Auto

,

 

and then 

back to  .

                        =  Disable Open Window Detection 
             

Auto

         =  Enable Open Window Detection

•  

LED 2 will flash as described above.

•  

Wait 7 seconds to confirm.

•  

After the 7 seconds has elapsed, the thermostat will 
return to normal operation.

TROUBLE SHOOTING

If the red LED (1, picture 4) flashes rapidly and 
continuously, a fault has been detected by the 
electronics. Contact your supplier.

In the event of a power cut while the thermostat is set 
to 

Auto

, or after a factory reset has been performed, LED 

1 and LED 2 will continuously flash one after the other, 
indicating that the thermostat has lost the time setting. 
Follow the procedure 

“HOW TO SELECT AND INITIATE 

HEATING PROGRAMS”

.

FACTORY RESET

The user defined program and set point temperatures 
can be reset to factory default settings. To perform a 
factory reset, follow the below steps:-

 

25

30

20

15

10

Auto

25

30

20

15

10

Auto

+

x5

25

30

20

15

10

Auto

+

•  

Rotate dial B to 

Auto

, then to   , then back to 

Auto

Repeat this sequence 5 times.

 

Auto

           

Auto

           

Auto

           

Auto

  

 

        

Auto

           

Auto

 LED 1 and LED 2 will then both flash 3 times.

  After this, LED 1 and LED 2 will continuously flash one 

after the other, indicating that the thermostat has lost 
the time setting.

5. MAINTENANCE, REPAIR 

AND DISPOSAL

• 

 

WARNING

: Disconnect electrical supply before carrying 

out any maintenance activity. 

•  

The product can be cleaned using a soft damp cloth.  
Do NOT use chemical or abrasive cleaners as they will 
damage the surface finish.

•  

The radiator is equipped with an overheat protection 
that cannot be reset (melt fuse). This overheat 
protection disconnects the current if the radiator 
becomes too hot (e.g. when covered) or if, when 
freestanding, is knocked over and left in this position.

•  

If the supply cord is damaged, it must be replaced by 
the manufacturer, his service agent or similar qualified 
persons in order to avoid a hazard.

•  

The radiator is filled with an exact amount of 
environmental friendly vegetable oil. Any repairs that 
require the radiator to be opened shall therefore only  
be carried out by the manufacturer or his approved 
agent. Please contact the manufacturer or his agent  
in case of leakage.

•  

When scrapping the radiator, follow the regulations 
concerning the disposal of oil.

 

13

 |

Summary of Contents for KABA C

Page 1: ...KABA INSTALLATION AND OPERATING MANUAL A NEW GENERATION THAT TURNS EVOLUTION INTO A REVOLUTION CLASS I 230V 400V 50 HZ ...

Page 2: ...S Zone 0 3m 2 25m 0 6m 0 6m A C B A H B C 46 373 A 100 150 100 150 46 173 H mm mm mm mm 300 500 A C B A H B C 46 373 A 100 150 100 150 46 173 H mm mm mm mm 300 500 Min 100mm Min 100mm Min 100mm Min 200mm Min 100mm KABA INSTALLATION AND OPERATING MANUAL 01 07 2018 ...

Page 3: ...3 PRODUCT INFORMATION 3C 3D CLICK 3mm CLICK 3B KABA INSTALLATION AND OPERATING MANUAL 01 07 2018 KABA P 230V PRODUCT ONLY ...

Page 4: ...NO PRODUCT INFORMATION 4 4 5A 5B LED 1 LED 2 B A KABA INSTALLATION AND OPERATING MANUAL 01 07 2018 ...

Page 5: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 6 24 0h 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 7 24 P5 0h 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 1 24 0h 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 2 24 0h 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 3 24 0h 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 ...

Page 6: ...96 EC Due to the safety standard EN 60335 the text below is obligatory for all electric products not only radiators This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the ...

Page 7: ...ng the fixing method used to secure the radiator to the wall the type and condition of the wall itself and any additional potential forces or weights prior to finalising installation The fixing materials provided are only intended for installation on walls made of solid wood bricks concrete or on timber frame stud walls where the fixing is into the timber All walls being considered should have no ...

Page 8: ... HOWTO CREATE AND INITIATE A USER DEFINED HEATING PROGRAM ATTENTION When rotating dial B to access any of these features a pause of 0 5 seconds must be made at each position This is to give the thermostat enough time to detect the dial position 25 30 20 15 10 Auto 25 30 20 15 10 Auto K 01 25 30 20 15 10 Auto K 02 25 30 20 15 10 Auto K 03 25 30 20 15 10 Auto 25 30 20 15 10 Auto K 04 U1 P1 P2 P4 P5 ...

Page 9: ... 7 seconds to confirm LED 2 will change to solid green for 1 second to indicate that the value has been stored The heating program is now running 30 20 15 10 Auto K 06 25 30 20 15 10 Auto K 07 Rotate dial B to Auto LED 1 and LED 2 will continue to flash as described in the table below Comfort Mode Reduced Mode Heating Not Heating Heating Not Heating LED 1 5s On 1s Off 1s On 5s Off Off Off LED 2 Of...

Page 10: ... red rapidly for 7 seconds During this time the Comfort set temperature can be selected by rotating dial B to the desired temperature value and then wait 7 seconds to confirm LED 1 will change to solid red for 1 second to indicate that the value has been stored 25 30 20 15 10 Auto K 05 25 30 20 15 10 Auto K 06 25 30 20 15 10 Auto K 07 LED 2 will then flash green rapidly for 7 seconds During this t...

Page 11: ...ly for 7 seconds During this time the Comfort set temperature can be selected by rotating dial B to the desired temperature value and then wait 7 seconds to confirm LED 1 will change to solid red for 1 second to indicate that the value has been stored The thermostat will then return to normal operation Rotate dial B to Auto ADJUSTING REDUCED MODE SET TEMPERATURE 25 30 20 15 10 Auto 25 30 20 15 10 ...

Page 12: ...y function when the radiator follows a heating program OPEN WINDOW DETECTION This function will switch the radiator from any active mode to Frost Protection mode when an open window is detected room temperature drops by more than 2 C in less than 10 minutes LED 1 and LED 2 will flash twice every 6 seconds when Frost Protection mode is active NOTE Normal operation will resume if there is any user i...

Page 13: ...st the time setting Follow the procedure HOW TO SELECT AND INITIATE HEATING PROGRAMS FACTORY RESET The user defined program and set point temperatures can be reset to factory default settings To perform a factory reset follow the below steps 25 30 20 15 10 Auto 25 30 20 15 10 Auto x5 25 30 20 15 10 Auto Rotate dial B to Auto then to then back to Auto Repeat this sequence 5 times Auto Auto Auto Aut...

Page 14: ...o 70 C SETTING TEMPERATURE RANGE Comfort mode Frost protection mode 5 C to 30 C 7 C ELECTRICAL INSULATION Class I ELECTRICAL PROTECTION IP44 POWER SUPPLY 230 VAC 50 Hz or 400 VAC 50 Hz according to the product rating label DIRECTIVES STANDARDS The product has been designed to comply with the following Directives and Standards EN 60730 1 EN 60335 1 EN 60335 2 30 EN 62233 EN 55014 1 EN 55014 2 EN 61...

Page 15: ...A manual heat charge control with room and or outdoor temperature feedback N A electronic heat charge control with room and or outdoor temperature feedback N A fan assisted heat output N A Type of heat output room temperature control single stage heat output and no room temperature control no two or more manual stages no room temperature control no with mechanic thermostat room temperature control...

Page 16: ...LVI_KABA_2018 07 01 ...

Reviews: