Fast cleaning instructions 

 

In order to clean the dirt separator filter rapidly, follow the below instructions: 
 

 

Turn off the boiler using the switches or knobs of the control panel and remove the boiler's plug from the power socket.  

 

Isolate the dirt separator filter from the heating system by closing both the valves upstream and downstream of the filter in 
order to avoid the emptying of the whole heating system. 

 

Remove the transparent bottom plug and take the magnet out of its housing.  

 

Unscrew  the  plastic  threaded  end  cap  (WARNING:  circuit  under  pressure)  and  collect  all  the  liquid  and  accumulated 
impurities in a container. 

 

Replace the plastic threaded end cap with its rubber gasket. 

 

Put the magnet into its housing again and insert the transparent plug. 

 

Slightly open the ball valves upstream and downstream of the dirt separator filter which have been previously closed. 

 

Adjust  the  pressure  of  the  heating  system  water  in  compliance  with  the  working  pressure  limit  values  indicated  by  the 
boiler's manufacturer. 

 

Annual cleaning instructions 

 

In order to carry out the annual cleaning operations, removing  the magnet and the metal mesh, follow the instructions below: 
 

 

Turn off the boiler using the switches or knobs of the control panel and remove the boiler's plug from the power socket.  

 

Isolate the dirt separator filter from the heating system by closing both the valves upstream and downstream of the filter in 
order to avoid the emptying of the whole heating system. 

 

Remove the transparent bottom plug and take the magnet out of its housing.  

 

Unscrew  the  plastic  threaded  end  cap  (WARNING:  circuit  under  pressure)  and  collect  all  the  liquid  and  accumulated 
impurities in a container. 

 

Unscrew the lower body and wash it with running water. 

 

Remove the metal mesh and wash it with running water. 

 

Remove the ferrous impurities which may have accumulated in the filter. 

 

Replace the metal mesh and the lower body with rubber gasket screwing it to the upper body. 

 

Replace the plastic threaded end cap with its rubber gasket. 

 

Put the magnet into its housing again and insert the transparent plug. 

 

Slightly open the ball valves upstream and downstream of the dirt separator filter which have been previously closed. 

 

Adjust  the  pressure  of  the  heating  system  water  in  compliance  with  the  working  pressure  limit  values  indicated  by  the 
boiler's manufacturer. 

 
Once the fast or annual cleaning have been completed, the heating circuit needs to be emptied of any air in excess. 
An accurate maintenance always enables saving and security. 

 

 

DANGER

 

Danger  of  burns  due  to  hot  water.  Never  open  the  dirt  separator  filter  while  the  boiler  is  working  and  the  circiut  is  under 
pressure. 
Danger of flooding, before disassembling the dirt separator filter, make sure that both the ball valves upstream and downstream 
of the dirt separator filter have been closed. 

 

FORBIDDEN

 

Before cleaning the dirt separator filter, turn off the boiler and disconnect it from the power supply. 
Do not block or reduce the openings for the flow of the heating circuit water. 

 

PRESENCE OF MAGNETIC FIELDS

 

Please  note  that  there  are  strong  magnetic  fields  which  can  damage  or  interfere  with  the  correct  functioning  of  electronic 
devices (pacemaker, magnetic badges, etc.). 

 

 