3
ENGLISH
Specifications
Input
Rated input voltage
DC 13 0.2 V
Operating voltage range
DC 11 V-15 V
Output
No-load output voltage
AC 230 V +/- 10 V (@ rated input voltage)
Load output voltage
AC 210 V ~ AC 240 V (@ rated input voltage)
Output frequency
50 Hz +/- 1 Hz
USB output
DC 5 V, 2100 mA
Continuous power
2000 W
Peak power
4000 W
Output wave
Pure sine wave
Max effiency
85%
No load
current
12 V Input
1.6 A
Low voltage
Input low-voltage alarm
DC 10.5 V +/- O.3 V
Input low-voltage
shut down
DC 9.5 V +/- O.3 V
Low-voltage
recovery voltage
When the input voltage rises to 12 V +/- 0.3 V,
the inverter automatically resumes operation.
Over voltage
Input over voltage
shut down
DC 16 V +/- O.3 V
Over-voltage
recovery voltage
When the input voltage drops to 14 V +/- 0.3 V,
the inverter automatically resumes operation.
Overload
Overload protection
Yes (2150-2300 W)
Over temp
Over temperature
protection
Yes
Over temperature recovery
When the temperature inside the inverter decreases to
the set point, the inverter will back to work automatically.
Short circuit
Output short circuit
protection
Yes
Reverse protection
Reverse connection will blow the fuse, fuse replacement
with the same specifications can fix the inverter.
Other
Working temperature
-15 °C ~ 35 °C
Fuse
35 A* 7
Cooling method
Fan. The fan speed is adjusted when the inside
temperature of the device is below 60 °C (+/-5 °C).
LCD display information
Input voltage, load power, output frequency,
output current, battery power, fault code.
Remote control
Yes. Equipped with RJ12 port, 6 m cable.