background image

 

LX307 

V. 02 – 21/04/2015 

©Velleman nv 

 

 

Ring 6 intensity (0-255) 

 

Ring 7 intensity (0-255) 

 

Ring 8 intensity (0-255) 

 

Ring 9 intensity (0-255) 

 

Ring 10 intensity (0-255) 

7.2

 

Stand-Alone Mode 

In stand-alone mode, the device runs one of the built-in programmes. 
To set the device to stand-alone mode: 

1.

 

Unplug any connection from the DMX input of the device. 

2.

 

Press MENU until <AuTo> or <dEMo> is displayed and press ENTER. 

3.

 

Use UP and DOWN to select the built-in programme and press ENTER. 

7.3

 

Master/Slave Mode 

Notes 

 

The master/slave mode allows for connecting several devices to a single master device in a daisy 
chain. 

 

All slave devices will then work synchronously with the master device. 

 

Configure all slave units before connecting the master unit to the daisy chain. 

 

The maximum number of slave units you can connect to a master unit is 18. 

Slave units: 
1.

 

Connect the DMX input from your slave device to the DMX output of the previous device in the 
chain. 

2.

 

Connect the slave device to the mains to switch it on. 

3.

 

Each connected slave device will automatically follow the master device. 

Master unit 
1.

 

Connect the master device to the mains to switch it on. 

2.

 

Set the master unit to work in one of the running modes. 

3.

 

Connect the master unit as the first unit in the chain by connecting the DMX output of the master 
device to the DMX input of the first slave unit. 

7.4

 

DMX Mode 

The DMX mode allows you to control the device with any universal DMX controller. 

 

All DMX-controlled devices need a digital start address so that the correct device responds to the 

signals. This digital start address is the channel number from which the device starts to “listen” to 
the DMX controller. The same starting address can be used for a whole group of devices or an 
individual address can be set for every device. 

 

When all devices have the same address, all the units will “listen” to the control signal on one 
particular channel. In other words: changing the settings of one channel will affect all devices 

simultaneously. If you set individual addresses, each device will “listen” to a separate channel 
number. Changing the settings of one channel will only affect the device in question. 

 

Summary of Contents for LX307

Page 1: ...LX307 NUXILED 1001 10 SEGMENT LED STROBE DMX CONTROLLED USER MANUAL...

Page 2: ...LX307 V 02 21 04 2015 2 Velleman nv...

Page 3: ...imilarly qualified persons in order to avoid any hazard Make sure that the available voltage does not exceed the voltage stated in the specifications of this manual This device falls under protection...

Page 4: ...Do not switch the device on immediately after it has been exposed to changes in temperature Protect the device against damage by leaving it switched off until it has reached room temperature This devi...

Page 5: ...its determining the installation material to be used Have the material and the device itself checked regularly Do not attempt to install the device yourself if you lack these qualifications as imprope...

Page 6: ...unction without saving the setting or quit the menu UP to scroll upward in a list of functions or options or increase a value DOWN to scroll downward in a list of functions or options or decrease a va...

Page 7: ...ins to switch it on 3 Each connected slave device will automatically follow the master device Master unit 1 Connect the master device to the mains to switch it on 2 Set the master unit to work in one...

Page 8: ...21 20 10 503 channel 1 10 11 20 21 30 channel mode 1st unit 2nd unit 3rd unit highest start address 13 start address 1 14 1 13 27 14 13 500 channel 1 13 14 26 27 39 DMX Channel Values 3 Channel Mode...

Page 9: ...s apart from the fuse Refer to an authorized dealer for service and or spare parts Replacing the fuse Only replace the fuse by a fuse of the same type and rating 1 Unplug the device s power cord from...

Page 10: ...shocks falls dust dirt humidity and by the article as well as its contents e g data loss compensation for loss of profits consumable goods parts or accessories that are subject to an aging process du...