Luxibel LX306 User Manual Download Page 8

 

LX306 

V. 03 – 30/07/2014 

©Velleman nv 

Flash 4 

000-005 
006-249 
250-255 

Blackout 
Flash rate, slow to fast 
Continuous blinder effect 

Flash 5 

000-005 
006-249 
250-255 

Blackout 
Flash rate, slow to fast 
Continuous blinder effect 

Flash 6 

000-005 
006-249 
250-255 

Blackout 
Flash rate, slow to fast 
Continuous blinder effect 

 
The LEDs can be controlled in 6 segments: 

 

10 channel mode 

channel 

Function 

Value 

Percent/Setting 

Flash 1 

000-005 
006-249 
250-255 

Blackout 
Flash rate, slow to fast 
Full on 

Flash 2 

000-005 
006-249 
250-255 

Blackout 
Flash rate, slow to fast 
Full on 

Flash 3 

000-005 
006-249 
250-255 

Blackout 
Flash rate, slow to fast 
Full on 

Flash 4 

000-005 
006-249 
250-255 

Blackout 
Flash rate, slow to fast 
Full on 

Flash 5 

000-005 
006-249 
250-255 

Blackout 
Flash rate, slow to fast 
Full on 

Flash 6 

000-005 
006-249 
250-255 

Blackout 
Flash rate, slow to fast 
Full on 

Auto Programs 

000-010 
011-040 
041-070 
071-100 
101-130 
131-160 
161-190 
191-220 
221-255 

No Function 
Auto 0 
Auto 1 
Auto 2 
Auto 3 
Auto 4 
Auto 5 
Auto 6 
Auto 7 

Auto speed 

000-255 

Auto speed slow to fast 

Dimmer 

000-255 

0 - 100% 

10 

Strobe 

000-005 
006-255 

No Function 
Strobe Slow to Fast 

Summary of Contents for LX306

Page 1: ...LX306 NUXILED 3000 DMX CONTROLLED LED STROBE USER MANUAL...

Page 2: ...imilarly qualified persons in order to avoid any hazard Make sure that the available voltage does not exceed the voltage stated in the specifications of this manual This device falls under protection...

Page 3: ...r any ensuing defects or problems Mechanical wear and LEDs are not covered by warranty A qualified technician shall install and service this device Do not switch the device on immediately after it has...

Page 4: ...multiple times to reduce the height of drop to a safe level Never stand directly below the device when it is being mounted removed or serviced Have a qualified technician check the device once a year...

Page 5: ...ng modes stand alone mode master slave with a DMX512 controller 7 1 Control Panel Navigation Access the control panel functions using the four panel buttons located directly underneath the display Fro...

Page 6: ...until M S Mode is displayed and press ENTER 3 Use UP and DOWN to select Master and press ENTER Slave 1 On each slave device press MENU until M S Mode is displayed and press ENTER 2 Use UP and DOWN to...

Page 7: ...ration 15 990 ms 3 Flash rate 000 005 006 255 No flash 1Hz 30 Hz 4 Special effects 000 005 006 042 043 085 086 128 129 171 172 214 215 255 No effect Ramp up Ramp down Ramp up down Random Lightning Spi...

Page 8: ...o fast Full on 2 Flash 2 000 005 006 249 250 255 Blackout Flash rate slow to fast Full on 3 Flash 3 000 005 006 249 250 255 Blackout Flash rate slow to fast Full on 4 Flash 4 000 005 006 249 250 255 B...

Page 9: ...ler for service and or spare parts Replacing the fuse Only replace the fuse by a fuse of the same type and rating 1 Unplug the device s power cord from the outlet 2 Use a flat head screwdriver to remo...

Page 10: ...article e g by oxidation shocks falls dust dirt humidity and by the article as well as its contents e g data loss compensation for loss of profits o consumable goods parts or accessories that are sub...

Reviews: