Luxibel LX306 User Manual Download Page 4

 

LX306 

V. 03 – 30/07/2014 

©Velleman nv 

 

5.

 

Overview 

 

 

 

6.

 

Installation 

Choose a suitable mounting spot. Mount the device in the desired angle using the included bracket. 
Connect the power cord to the mains. Disconnect after use. 

Mounting the Device 

 

Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable 
norms. 

 

The carrying construction must be able to support 10 times the weight of the device for 1 hour 
without deforming. 

 

For truss mounting, use an appropriate clamp (not incl.) and fit an M10 bolt through the centre of the 
(folded) bracket. 

 

The installation must always be secured with a secondary attachment such as a safety cable 

(e.g. VDLSC7N or VDLSC8N). The secondary attachment shall be designed and mounted in such a 
way that no part of the device can fall if the primary attachment fails. 

 

Make sure that the safety cables can carry 10 times the weight of the device. Make sure that the 

maximum height of drop is limited so that no injuries can occur. If the safety cables are long, wrap 
them around the truss multiple times to reduce the height of drop to a safe level. 

 

Never stand directly below the device when it is being mounted, removed or serviced. Have a 
qualified technician check the device once a year and once before you bring it into service. 

 

Install the device in a location with few passers-by that is inaccessible to unauthorised persons. 

 

Overhead mounting requires extensive experience: calculating workload limits, determining the 

installation material to be used… Have the material and the device itself checked regularly. Do not 
attempt to install the device yourself if you lack these qualifications as improper installation may 
result in injuries. 

 

Make sure there is no flammable material within a 0.5 m radius of the device. 

 

Have a qualified electrician carry out the electric connection. 

 

Connect the device to the mains with the power plug. All devices must be powered directly off a 

grounded switched circuit and cannot be run off a rheostat or dimmer circuit, even if the rheostat or 
dimmer channel is used solely for 0 % to 100 % switching. 

 

The device has a power output to supply power to another device. When connecting several devices 
in a daisy chain via this output, make sure that the total current does not exceed the power line’s 

Summary of Contents for LX306

Page 1: ...LX306 NUXILED 3000 DMX CONTROLLED LED STROBE USER MANUAL...

Page 2: ...imilarly qualified persons in order to avoid any hazard Make sure that the available voltage does not exceed the voltage stated in the specifications of this manual This device falls under protection...

Page 3: ...r any ensuing defects or problems Mechanical wear and LEDs are not covered by warranty A qualified technician shall install and service this device Do not switch the device on immediately after it has...

Page 4: ...multiple times to reduce the height of drop to a safe level Never stand directly below the device when it is being mounted removed or serviced Have a qualified technician check the device once a year...

Page 5: ...ng modes stand alone mode master slave with a DMX512 controller 7 1 Control Panel Navigation Access the control panel functions using the four panel buttons located directly underneath the display Fro...

Page 6: ...until M S Mode is displayed and press ENTER 3 Use UP and DOWN to select Master and press ENTER Slave 1 On each slave device press MENU until M S Mode is displayed and press ENTER 2 Use UP and DOWN to...

Page 7: ...ration 15 990 ms 3 Flash rate 000 005 006 255 No flash 1Hz 30 Hz 4 Special effects 000 005 006 042 043 085 086 128 129 171 172 214 215 255 No effect Ramp up Ramp down Ramp up down Random Lightning Spi...

Page 8: ...o fast Full on 2 Flash 2 000 005 006 249 250 255 Blackout Flash rate slow to fast Full on 3 Flash 3 000 005 006 249 250 255 Blackout Flash rate slow to fast Full on 4 Flash 4 000 005 006 249 250 255 B...

Page 9: ...ler for service and or spare parts Replacing the fuse Only replace the fuse by a fuse of the same type and rating 1 Unplug the device s power cord from the outlet 2 Use a flat head screwdriver to remo...

Page 10: ...article e g by oxidation shocks falls dust dirt humidity and by the article as well as its contents e g data loss compensation for loss of profits o consumable goods parts or accessories that are sub...

Reviews: