Luxibel LX306 User Manual Download Page 7

 

LX306 

V. 03 – 30/07/2014 

©Velleman nv 

Channel mode 

First unit 

Second unit 

Third unit 

Highest 

start address 

Start address 

6 (1 + 5) 

11 (6 + 5) 

508 

 

Channel 

1 - 5 

6 - 10 

11 - 15 

 

Start address 

7 (1 + 6) 

13 (7 + 6) 

507 

 

Channel 

1 - 6 

7 - 12 

13 - 18 

 

10 

Start address 

11 (1 + 10) 

21 (11 + 10) 

503 

 

Channel 

1 - 10 

11 - 20 

21 - 30 

 

7.5

 

DMX Channel Values 

1 channel mode 

channel 

Function 

Value 

Percent/Setting 

Flash 

000-005 
006-249 
250-255 

Blackout 
Flash rate, slow to fast 
Continuous blinder effect 

5 channel mode 

channel 

Function 

Value 

Percent/Setting 

Flash intensity 

000-005 
006-255 

Black out 
Minimum to maximum 

Flash duration 

000-255 

Flash duration 
15 – 990 ms 

Flash rate 

000-005 
006-255 

No flash 
1Hz – 30 Hz 

Special effects 

000-005 
006-042 
043-085 
086-128 
129-171 
172-214 
215-255 

No effect 
Ramp up 
Ramp down 
Ramp up-down 
Random 
Lightning 
Spikes 

Pixel  control 
macros 

000-005 
006-042 
043-085 
086-128 
129-171 
172-214 
215-255 

No effect 
Macro 1 (slow to fast) 
Macro 2 (slow to fast) 
Macro 3 (slow to fast) 
Macro 4 (slow to fast) 
Macro 5 (slow to fast) 
Macro 6 (slow to fast) 
Channels 1, 2, 3 and 4 are available in 5-channel 
mode. 

6 channel mode 

channel 

Function 

Value 

Percent/Setting 

Flash 1 

000-005 
006-249 
250-255 

Blackout 
Flash rate, slow to fast 
Continuous blinder effect 

Flash 2 

000-005 
006-249 
250-255 

Blackout 
Flash rate, slow to fast 
Continuous blinder effect 

Flash 3 

000-005 
006-249 
250-255 

Blackout 
Flash rate, slow to fast 
Continuous blinder effect 

Summary of Contents for LX306

Page 1: ...LX306 NUXILED 3000 DMX CONTROLLED LED STROBE USER MANUAL...

Page 2: ...imilarly qualified persons in order to avoid any hazard Make sure that the available voltage does not exceed the voltage stated in the specifications of this manual This device falls under protection...

Page 3: ...r any ensuing defects or problems Mechanical wear and LEDs are not covered by warranty A qualified technician shall install and service this device Do not switch the device on immediately after it has...

Page 4: ...multiple times to reduce the height of drop to a safe level Never stand directly below the device when it is being mounted removed or serviced Have a qualified technician check the device once a year...

Page 5: ...ng modes stand alone mode master slave with a DMX512 controller 7 1 Control Panel Navigation Access the control panel functions using the four panel buttons located directly underneath the display Fro...

Page 6: ...until M S Mode is displayed and press ENTER 3 Use UP and DOWN to select Master and press ENTER Slave 1 On each slave device press MENU until M S Mode is displayed and press ENTER 2 Use UP and DOWN to...

Page 7: ...ration 15 990 ms 3 Flash rate 000 005 006 255 No flash 1Hz 30 Hz 4 Special effects 000 005 006 042 043 085 086 128 129 171 172 214 215 255 No effect Ramp up Ramp down Ramp up down Random Lightning Spi...

Page 8: ...o fast Full on 2 Flash 2 000 005 006 249 250 255 Blackout Flash rate slow to fast Full on 3 Flash 3 000 005 006 249 250 255 Blackout Flash rate slow to fast Full on 4 Flash 4 000 005 006 249 250 255 B...

Page 9: ...ler for service and or spare parts Replacing the fuse Only replace the fuse by a fuse of the same type and rating 1 Unplug the device s power cord from the outlet 2 Use a flat head screwdriver to remo...