7.

 

Cleaning and Maintenance 

 

All screws should be tightened and free of corrosion. 

 

The housing, the lenses, the mounting supports and the installation location (e.g. ceiling, suspension, 

trussing) should not be deformed, modified or tampered with; e.g. do not drill extra holes in 
mounting supports, do not change the location of the connections… 

 

Mechanically moving parts must not show any signs of wear and tear. 

 

The electric power supply cables must not show any damage. Have a qualified technician maintain 
the device. 

 

Disconnect the device from the mains prior to maintenance activities. Let the device cool down. 

 

Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents. 

 

Do not immerse the device in any liquid. 

 

There are no user-serviceable parts, apart from the fuse. 

 

Contact your dealer for spare parts if necessary. 

Replacing the Fuse 

Only replace the fuse by a fuse of the same type and rating. 

1.

 

Before replacing the fuse, unplug the mains lead. 

2.

 

Unscrew the fuse holder with an appropriate screwdriver. 

3.

 

Remove the old fuse and install the new fuse in the fuse holder. 

4.

 

Place the fuse holder back in the housing and tighten it. 

8.

 

Technical Specifications 

 

power supply ........................................................................... 100-240 V~, 50/60 Hz 

 

power consumption ......................................................................................... 340 W 

 

LED source ............................................. 25 high-power 2-colour CCWW LEDs (Tianxin) 

 

beam angle ......................................................................................................... 4° 

 

pitch ............................................................................................................ 77 mm 

 

DMX in- and output .......................................................................... 3- and 5-pin XLR 

 

Artnet/Kling-Net ........................................................................... UTP in- and output 

 

IP rate ............................................................................................................. IP20 

 

dimensions ................................................................................ 425 x 395 x 213 mm 

 

weight ......................................................................................................... 11.5 kg 

 

Use this device with original accessories only. Velleman nv cannot be held responsible in the 
event of damage or injury resulting from (incorrect) use of this device. For more info 

concerning this product and the latest version of this manual, please visit our website 
www.luxibel.com. The information in this manual is subject to change without prior notice. 

 

© COPYRIGHT NOTICE 
The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. 

No part 

of this manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise 
without the prior written consent of the copyright holder.  
 

Summary of Contents for LX131

Page 1: ...LX131 CYBERPIX CCWW 5x5 MATRIX PANEL USER MANUAL...

Page 2: ...LX131 V 01 14 09 2015 2 Velleman nv...

Page 3: ...r use only Keep this device away from rain moisture splashing and dripping liquids Never put objects filled with liquids on top of or close to the device Keep this device away from children and unauth...

Page 4: ...exposed to changes in temperature Protect the device against damage by leaving it switched off until it has reached room temperature This device is designed for professional use on stage in discos the...

Page 5: ...rial and the device itself checked regularly Do not attempt to install the device yourself if you lack these qualifications as improper installation may result in injuries For truss mounting use an ap...

Page 6: ...and the other side to the male XLR input of the device Multiple devices can be linked through serial linking The linking cable shall be a dual core screened cable with XLR input and output connectors...

Page 7: ...e value DOWN scroll through the menu options in descending order decrease value Menu 1 Set DMX Address 1 512 DMX address 1 512 Cancel exit without saving Enter save changes 2 Set Channel Mode 2 channe...

Page 8: ...l Control The device starts running in stand alone mode after connection to the mains This mode allows you to use the device without controller 1 Connect the device to the mains to switch it on 2 Pres...

Page 9: ...100 2 warm white 1 000 255 warm white 1 from 0 100 3 cool white 2 000 255 cool white 2 from 0 100 4 warm white 2 000 255 warm white 2 from 0 100 5 cool white 3 000 255 cool white 3 from 0 100 6 warm w...

Page 10: ...ing 1 Before replacing the fuse unplug the mains lead 2 Unscrew the fuse holder with an appropriate screwdriver 3 Remove the old fuse and install the new fuse in the fuse holder 4 Place the fuse holde...

Page 11: ...shocks falls dust dirt humidity and by the article as well as its contents e g data loss compensation for loss of profits consumable goods parts or accessories that are subject to an aging process du...

Reviews: