background image

 

LX131 

V. 01 – 14/09/2015 

©Velleman nv 

To set the device to work with a DMX controller: 

1.

 

Press MENU until <Set Channel Mode> is displayed and press ENTER. 

2.

 

Use UP and DOWN to select a channel mode and press ENTER. 

3.

 

Press MENU until <Set DMX Address> is displayed and press ENTER. 

4.

 

Use <UP> and <DOWN> to set the DMX start address and press ENTER. 

Start addresses 

Use the table below to define the correct address. The table shows the settings for units 1 to 3. Apply the 
same principle for the other units. Example: 

 

channel mode 

1

st

 unit 

2

nd

 unit 

3

rd

 unit 

highest start address 

start address 

3 (1 + 2) 

5 (3 + 2) 

511 

 

channel 

1 - 2 

3 - 4 

5 - 6 

 

DMX Channel Values 

 

2-channel mode 

 

channel 

function 

from 

to 

description 

cool white 

000 

255 

red from 0-100 % 

warm white 

000 

255 

green from 0-100 % 

 

10-channel mode 

 

channel 

function 

from 

to 

description 

cool white 1 

000 

255 

cool white 1 from 0-100 % 

warm white 1 

000 

255 

warm white 1 from 0-100 % 

cool white 2 

000 

255 

cool white 2 from 0-100 % 

warm white 2 

000 

255 

warm white 2 from 0-100 % 

cool white 3 

000 

255 

cool white 3 from 0-100 % 

warm white 3 

000 

255 

warm white 3 from 0-100 % 

cool white 4 

000 

255 

cool white 4 from 0-100 % 

warm white 4 

000 

255 

warm white 4 from 0-100 % 

cool white 5 

000 

255 

cool white 5 from 0-100 % 

10 

warm white 5 

000 

255 

warm white 5 from 0-100 % 

 

50-channel mode 

 

channel 

function 

from 

to 

description 

cool white 1 

000 

255 

cool white 1 from 0-100 % 

warm white 1 

000 

255 

warm white 1 from 0-100 % 

cool white 2 

000 

255 

cool white 2 from 0-100 % 

warm white 2 

000 

255 

warm white 2 from 0-100 % 

cool white 3 

000 

255 

cool white 3 from 0-100 % 

warm white 3 

000 

255 

warm white 3 from 0-100 % 

cool white 4 

000 

255 

cool white 4 from 0-100 % 

warm white 4 

000 

255 

warm white 4 from 0-100 % 

… 

… 

… 

… 

… 

47 

cool white 24 

000 

255 

cool white 24 from 0-100 % 

48 

warm white 24 

000 

255 

warm white 24 from 0-100 % 

49 

cool white 25 

000 

255 

cool white 25 from 0-100 % 

50 

warm white 25 

000 

255 

warm white 25 from 0-100 % 

Summary of Contents for LX131

Page 1: ...LX131 CYBERPIX CCWW 5x5 MATRIX PANEL USER MANUAL...

Page 2: ...LX131 V 01 14 09 2015 2 Velleman nv...

Page 3: ...r use only Keep this device away from rain moisture splashing and dripping liquids Never put objects filled with liquids on top of or close to the device Keep this device away from children and unauth...

Page 4: ...exposed to changes in temperature Protect the device against damage by leaving it switched off until it has reached room temperature This device is designed for professional use on stage in discos the...

Page 5: ...rial and the device itself checked regularly Do not attempt to install the device yourself if you lack these qualifications as improper installation may result in injuries For truss mounting use an ap...

Page 6: ...and the other side to the male XLR input of the device Multiple devices can be linked through serial linking The linking cable shall be a dual core screened cable with XLR input and output connectors...

Page 7: ...e value DOWN scroll through the menu options in descending order decrease value Menu 1 Set DMX Address 1 512 DMX address 1 512 Cancel exit without saving Enter save changes 2 Set Channel Mode 2 channe...

Page 8: ...l Control The device starts running in stand alone mode after connection to the mains This mode allows you to use the device without controller 1 Connect the device to the mains to switch it on 2 Pres...

Page 9: ...100 2 warm white 1 000 255 warm white 1 from 0 100 3 cool white 2 000 255 cool white 2 from 0 100 4 warm white 2 000 255 warm white 2 from 0 100 5 cool white 3 000 255 cool white 3 from 0 100 6 warm w...

Page 10: ...ing 1 Before replacing the fuse unplug the mains lead 2 Unscrew the fuse holder with an appropriate screwdriver 3 Remove the old fuse and install the new fuse in the fuse holder 4 Place the fuse holde...

Page 11: ...shocks falls dust dirt humidity and by the article as well as its contents e g data loss compensation for loss of profits consumable goods parts or accessories that are subject to an aging process du...

Reviews: