6. Installation of the product
Perform the following steps for the installation of the Product.
CAUTION:
Electrical installation must be carried out correctly and by authorized electricians only.
Outside every room where direct UVC light is used, there must be warning sings in clear line of sight.
Extra signals can be added that specify the hours of use or other important relevant notifications
6.1 Handling
Avoid physical shocks or jarring of the unit
Always handle the unit by the metal enclosure; never touch the tubes or reflectors with your fingertips. The moisture or
oils on your fingertips can damage the coating of the lenses.
6.2 Choose the appropriate location
Choosing the appropriate location is important for the proper functioning and safe use of the Product.
Install the Product in a protected area where the temperature does not fall below 5° C and the humidity level is low. The
Product functions ideally in a temperature range from 15°C to 25° C.
6.3 Remove the shipping assembly
Remove the tape from the box and open the box. Take the unit out of box and remove wrapping that protects the unit.
Make a visual inspection of the unit.
Please check condition of units while unpacking, if any damages occur, the unit must be repaired/replaced before it can
be used. Please contact your local distributor for service.
If units are damaged and still used, Luxibel cannot be held liable for any risk/danger or occurrence given by these dam-
aged units.
6.4 Before installing the Product
Read and save all notices, warnings and safety instructions received with the Product. Inspect the Product for damage
and verify the proper functioning of its the safety features. Do not operate the Product if in case of actual or suspected
damage or if its safety features do not function properly.
Every UVC installation must have an electrical inspection and approval before it can be deployed.
6.5 UVC Lamp Installation
B Air comes included with 2x Philips 30W TUV T8 fluorescent lamps. These are installed in the unit.
CAUTION:
Do not touch the lamp without gloves. Damage to the lamp may result. Oil from fingerprints
will permanently etch the glass of the lamp and weaken the structure.