background image

Luxibel B Air manual        5

Bedrijvenpark De Veert 13/004, 2830 Willebroek | +32 3 860 73 50 | [email protected] | www.luxibel.com

6.  Installation of the product

Perform the following steps for the installation of the Product.

CAUTION: 

Electrical installation must be carried out correctly and by authorized electricians only.

Outside every room where direct UVC light is used, there must be warning sings in clear line of sight.  

Extra signals can be added that specify the hours of use or other important relevant notifications

6.1  Handling

Avoid physical shocks or jarring of the unit
Always handle the unit by the metal enclosure; never touch the tubes or reflectors with your fingertips. The moisture or 
oils on your fingertips can damage the coating of the lenses.

6.2  Choose the appropriate location

Choosing the appropriate location is important for the proper functioning and safe use of the Product. 

Install the Product in a protected area where the temperature does not fall below 5° C and the humidity level is low. The 
Product functions ideally in a temperature range from 15°C to 25° C.

6.3  Remove the shipping assembly

Remove the  tape from the box and open  the box. Take the unit out of box and remove wrapping that protects the unit. 
Make a visual inspection of the unit. 

Please check condition of units while unpacking, if any damages occur, the unit must be repaired/replaced before it can 
be used. Please contact your local distributor for service. 

If units are damaged and still used, Luxibel cannot be held liable for any risk/danger or occurrence given by these dam-
aged units.

6.4  Before installing the Product

Read and save all notices, warnings and safety instructions received with the Product. Inspect the Product for damage 
and verify the proper functioning of its the safety features. Do not operate the Product if in case of actual or suspected 
damage or if its safety features do not function properly.

Every UVC installation must have an electrical inspection and approval before it can be deployed.

6.5  UVC Lamp Installation

B Air comes included with 2x Philips 30W TUV T8 fluorescent lamps. These are installed in the unit.

CAUTION:

 Do not touch the lamp without gloves. Damage to the lamp may result. Oil from fingerprints 

will permanently etch the glass of the lamp and weaken the structure.

Summary of Contents for B Air

Page 1: ...ithout further notice No rights can be derived from this manual No part of this manual may be reproduced in any form or by any means without prior written consent from AED Distribution NV Belgium Luxi...

Page 2: ...he product as described herein contains components that emit UVC light Immediate or prolonged exposure to UVC light can result in painful injury such as eye injury skin burn premature skin aging or sk...

Page 3: ...ry which can be poisonous at certain con centrations Avoid direct or indirect lighting on eyes or skin of humans or animals exposure to direct or strongly reflected UVC light Basic safety instructions...

Page 4: ...must strictly observe the instructions set out herein If you are an employee or are acting on be half of another person your employer that person must instruct you in accordance with the Manual and e...

Page 5: ...s may no longer emit the required level of ultraviolet radiation to ensure the desired effect on bacteria or fungi Technical data Type B Air Voltage 230 V 50 Hz power factor 0 989 Isolation Class I re...

Page 6: ...perature range from 15 C to 25 C 6 3 Remove the shipping assembly Remove the tape from the box and open the box Take the unit out of box and remove wrapping that protects the unit Make a visual inspec...

Page 7: ...disconnected prior to connecting the unit or making any changes to cabling con figurations Electrical installation must be carried out correctly by authorized electricians Standard 230V 50Hz Brown Li...

Page 8: ...disconnect the power supply Clean the external surfaces with a soft cloth and non aggressive cleaning agents only 8 1 Air filters Luxibel recommends to clean out the airfilters at least twice a year...

Page 9: ...e from the holders 7 Insert the new lamp with the dowels into the slots of the holders and rotate it about 90 around the axis to lock it 8 Slide unit back inside and reconnect earth cable 9 Install th...

Page 10: ...nd working methods known to us at the time of issue of the manual and is therefore subject at any time to change or amendment and the right to change or amend is hereby expressly reserved The instruct...

Page 11: ...AED Distribution NV Bedrijvenpark De Veert 13 004 2830 Willebroek Belgium 32 3 860 76 50 info luxibel com www luxibel com www AEDgroup com...

Reviews: