9.  Replacement of the UVC lamp

Luxibel recommends replacing the UVC lamp once a year and each time when its output falls below 80% of initial radi-
ometer reading. 

Following steps need to be taken for replacing a UVC lamp:

1.  Unscrew 4 bolts from both side of the unit
2.  Take off protection grill and air filter on both sides.
3.  Unscrew the 4 bolts that hold the bracket
4.  Disconnect earth cable from bracket
5.  Slide inside lamp holder 50% out until you can acces the lamps:
6.  Carefully grasp the glass bulb of the source (use cotton gloves), rotate it about 90° around the 

axis and remove from the holders.

7.  Insert the new lamp with the dowels into the slots of the holders and rotate it about 90° around 

the axis to lock it.

8.  Slide unit back inside and reconnect earth cable
9.  Install the screws of the bracket
10. Install airfilter and protection grill on both sides

CAUTION:

 Always disconnect power to the Product before replacing the UVC lamp.

NOTE:

 Use only the original specified spare parts, including Philips UVC lamps. Use of other spare parts may result in 

damage to the Product.

10.  Repairs

If the Product is damaged or malfunctions, contact the Luxibel Service Department or a Luxibel authorized distributor. 
Repairs by parties other than Luxibel or a Luxibel authorized distributor may not involve the use of Luxibel genuine parts 
and may affect the safety and functionality of the Product. 

For repair options or specific inquiries, please contact the Luxibel Service Department.

Summary of Contents for B Air

Page 1: ...ithout further notice No rights can be derived from this manual No part of this manual may be reproduced in any form or by any means without prior written consent from AED Distribution NV Belgium Luxi...

Page 2: ...he product as described herein contains components that emit UVC light Immediate or prolonged exposure to UVC light can result in painful injury such as eye injury skin burn premature skin aging or sk...

Page 3: ...ry which can be poisonous at certain con centrations Avoid direct or indirect lighting on eyes or skin of humans or animals exposure to direct or strongly reflected UVC light Basic safety instructions...

Page 4: ...must strictly observe the instructions set out herein If you are an employee or are acting on be half of another person your employer that person must instruct you in accordance with the Manual and e...

Page 5: ...s may no longer emit the required level of ultraviolet radiation to ensure the desired effect on bacteria or fungi Technical data Type B Air Voltage 230 V 50 Hz power factor 0 989 Isolation Class I re...

Page 6: ...perature range from 15 C to 25 C 6 3 Remove the shipping assembly Remove the tape from the box and open the box Take the unit out of box and remove wrapping that protects the unit Make a visual inspec...

Page 7: ...disconnected prior to connecting the unit or making any changes to cabling con figurations Electrical installation must be carried out correctly by authorized electricians Standard 230V 50Hz Brown Li...

Page 8: ...disconnect the power supply Clean the external surfaces with a soft cloth and non aggressive cleaning agents only 8 1 Air filters Luxibel recommends to clean out the airfilters at least twice a year...

Page 9: ...e from the holders 7 Insert the new lamp with the dowels into the slots of the holders and rotate it about 90 around the axis to lock it 8 Slide unit back inside and reconnect earth cable 9 Install th...

Page 10: ...nd working methods known to us at the time of issue of the manual and is therefore subject at any time to change or amendment and the right to change or amend is hereby expressly reserved The instruct...

Page 11: ...AED Distribution NV Bedrijvenpark De Veert 13 004 2830 Willebroek Belgium 32 3 860 76 50 info luxibel com www luxibel com www AEDgroup com...

Reviews: