3. DIP switches 9 -11 must be set as follows.
DIP 9
DIP 10
DIP 11
ON
ON
OFF
4. If additional external contacts are wired to the Detector, remove the jumper link S on the
PCB.
IMPORTANT:
If external contacts are not connected then jumper link SW must be fitted for
the Detector to operate correctly.
Testing the Magnetic Contact Detector
Ensure that the system is in Test/Service Mode
1. Remove the battery cover from the Detector.
As the battery cover is removed the LED on the Detector will illuminate for approx. 1 second to
indicate that the tamper switch has been activated.
. Open the door/window. As the Magnet is moved away from the Detector the LED will illuminate
for approx. 1 second to indicate that the Detector has been triggered.
3. If connected, operate the wired Magnetic Contact.
As the contact is opened the LED on the Detector should illuminate for 1 second to indicate that
it has been triggered.
4. Replace the battery cover on the Detector.
5. It is recommended that the operation of the Detector is also tested with the alarm in normal
operating mode to ensure that the Detector will successfully trigger a Full Alarm condition.