445073-LTG-A-0109
8
Johnson Controls Unitary Products
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
ACCESSORIES
Refer to Price Manual for specific model numbers.
Start Assist Kit (2SA067*) -
May be required on 42, 48, 60
models. Models 18, 24, 30, 36 have been factory installed.
Blower Time Delay
- Available to increase efficiency when
installed. Installs on indoor section and maintains blower for
approximately one minute after cooling thermostat has been
satisfied.
Hard Start Kits -
Provides required starting torque for use with
Thermal Expansion Valve Kit.
Low Temperature Cutout (2LT06700224) -
Prevents heat
pump operation below -1
°F ambient temperature.
Compressor Blanket -
Designed to further reduce the normal
operating sound.
Add-on Fossil Fuel Control -
Interface controls for use with
gas, oil furnaces and the heat pump system are available.
Thermal Expansion Valve Kit -
1TVM900 Series TXV kit used
to improve system performance.
Outdoor Thermostat (2TD06700124) -
Provides additional
staging of supplemental electric heat.
Room Thermostats -
A wide selection of matching thermostats
is available to provide features required for any installation.
2H/1C, manual changeover electronic non-programmable ther-
mostat.
3H/2C, non-programmable digital thermostat.
3H/2C, auto/manual changeover, electronic programmable, 7-
day, hardwire thermostat.
* For the most current accessory information, refer to the price
book or consult factory.
SOUND POWER RATINGS
* Rated in accordance with ARI 270-95 Standards.
THRD42S41S1
L*(8,L)C*C16
FC/MC/PC/UC48C
40.0
3.95
2.64
23.4
2.76
2.17
8.75
L*9C*C16
FC/MC/PC/UC48C
40.0
3.95
2.64
23.4
2.76
2.17
8.75
L*(8,L)C*C20
FC/MC/PC/UC48C
40.0
3.95
2.64
23.4
2.76
2.17
8.75
L*9C*C20
FC/MC/PC/UC48C
40.0
3.95
2.64
23.4
2.76
2.17
8.75
L*9C*D20
FC/MC/PC/UC48D
40.0
3.95
2.64
23.4
2.76
2.17
8.75
L*(8,L)C*C16
FC/PC/UC60C
40.5
4.00
2.64
23.4
2.76
2.17
8.75
L*9C*C16
FC/PC/UC60C
40.5
4.00
2.64
23.4
2.76
2.17
8.75
L*(8,L)C*C20
FC/PC/UC60C
40.5
4.00
2.64
23.4
2.76
2.17
8.75
L*9C*C20
FC/PC/UC60C
40.5
4.00
2.64
23.4
2.76
2.17
8.75
L*9C*D20
FC/MC/PC/UC60D
40.5
4.00
2.64
23.4
2.76
2.17
8.75
L*9C*D20
HC60
40.5
4.00
2.64
23.4
2.76
2.17
8.75
THRD48S41S1
L*(8,L)C*C20
FC/MC62D
46.0
4.00
3.10
27.0
2.78
1.82
8.20
L*9C*C20
FC/MC62D
46.0
4.00
3.10
27.0
2.78
1.82
8.20
L*9C*D20
FC/MC62D
46.0
4.00
3.10
27.0
2.78
1.82
8.20
THRD60S41S1
L*(8,L)C*C20
FC/MC62D
55.5
3.42
4.11
34.6
2.44
3.51
8.00
L*9C*C20
FC/MC62D
56.0
3.36
4.24
35.0
2.40
3.63
8.00
L*9C*D20
FC/MC62D
56.0
3.46
4.10
35.0
2.42
3.59
8.00
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
HEATING CAPACITY - With Variable Speed Furnaces (Continued)
UNIT
MODEL
VARIABLE
SPEED
FURNACE
COIL
1
MODEL
ARI HEATING
2
47
F
17
F
HSPF
MBH
COP
KW
MBH
COP
KW
STD
13 SEER HP WITH VARIABLE SPEED FURNACES
3
UNIT MODEL
(dBA)*
Cooling
Heating
018
73.1
80.4
024
72.9
75.0
030
76.8
80.4
036
76.5
78.2
042
72.7
75.2
048
76.7
78.1
060
77.2
78.9