Johnson Controls Unitary Products
5
445073-LTG-A-0109
COOLING CAPACITY - With Variable Speed Furnaces
UNIT
MODEL
VARIABLE SPEED
FURNACE MODEL
COIL
MODEL
1
W
COOLING
RATED
CFM
Net MBH
SEER
EER
TOTAL
SENS.
13 SEER HP WITH VARIABLE SPEED FURNACES
2
THRD18S41S1
L*(8,L)C*A12
FC/MC/PC/UC24A
14
600
18.0
13.5
13.00
11.00
L*(8,L)C*B12
FC/MC/PC/UC24B
17
580
18.0
13.5
13.00
11.00
L*9C*B12
FC/MC/PC/UC24B
17
600
18.0
13.5
13.00
11.00
L*(8,L)C*A12
FC/MC/PC/UC30A
14
600
18.0
13.5
13.00
11.00
L*(8,L)C*B12
FC/MC/PC/UC30B
17
580
18.0
13.5
13.00
11.00
L*9C*B12
FC/MC/PC/UC30B
17
600
18.0
13.5
13.00
11.00
L*(8,L)C*A12
HC30
14
600
18.0
13.5
13.00
11.00
THRD24S41S1
L*(8,L)C*A12
FC/MC/PC/UC24A
14
815
23.6
18.0
13.00
11.00
L*(8,L)C*B12
FC/MC/PC/UC24B
17
775
23.6
18.0
13.00
11.10
L*9C*B12
FC/MC/PC/UC24B
17
760
23.6
18.0
13.00
11.00
L*(8,L)C*A12
FC/MC/PC/UC30A
14
815
23.6
18.0
13.00
11.00
L*(8,L)C*B12
FC/MC/PC/UC30B
17
775
23.6
18.0
13.00
11.10
L*9C*B12
FC/MC/PC/UC30B
17
760
23.6
18.0
13.00
11.00
L*(8,L)C*A12
HC30
14
815
23.6
18.0
13.00
11.00
THRD30S41S1
L*(8,L)C*B12
FC/MC/PC/UC43B
17
960
30.0
21.7
13.00
11.25
L*9C*B12
FC/MC/PC/UC43B
17
1000
30.0
21.7
13.00
11.15
L*(8,L)C*C16
FC/MC/PC/UC43C
21
1000
30.0
21.7
13.00
11.40
L*9C*C16
FC/MC/PC/UC43C
21
995
30.0
21.7
13.00
11.25
L*9V*C16
FC/MC/PC/UC43C
21
995
30.0
21.7
13.00
11.25
L*(8,L)C*C16
HC42
21
1000
30.0
21.7
13.00
11.40
L*9C*C16
HC42
21
995
30.0
21.7
13.00
11.25
THRD36S41S1
L*(8,L)C*C16
FC/MC/PC/UC43C
21
1200
34.2
25.0
13.00
11.00
L*9C*C16
FC/MC/PC/UC43C
21
1175
34.2
25.0
13.00
11.00
L*(8,L)C*C20
FC/MC/PC/UC43C
21
1270
34.2
25.0
13.00
11.00
L*9C*C20
FC/MC/PC/UC43C
21
1270
34.2
25.0
13.00
11.00
L*(8,L)C*C16
HC42
21
1200
34.2
25.0
13.00
11.00
L*9C*C16
HC42
21
1175
34.2
25.0
13.00
11.00
L*(8,L)C*C20
HC42
21
1270
34.2
25.0
13.00
11.00
L*9C*C20
HC42
21
1270
34.2
25.0
13.00
11.00
THRD42S41S1
L*(8,L)C*C16
FC/MC/PC/UC48C
21
1430
40.5
31.6
13.00
11.50
L*9C*C16
FC/MC/PC/UC48C
21
1385
40.5
31.6
13.00
11.30
L*9V*C16
FC/MC/PC/UC48C
21
1385
40.5
31.6
13.00
11.30
L*(8,L)C*C20
FC/MC/PC/UC48C
21
1370
40.5
31.6
13.00
11.60
L*9C*C20
FC/MC/PC/UC48C
21
1445
40.5
31.6
13.00
11.40
L*9C*D20
FC/MC/PC/UC48D
24
1435
40.5
31.6
13.00
11.45
L*(8,L)C*C16
FC/PC/UC60C
21
1430
40.5
31.6
13.00
11.55
L*9C*C16
FC/PC/UC60C
21
1385
40.5
31.6
13.00
11.35
L*(8,L)C*C20
FC/PC/UC60C
21
1370
40.5
31.6
13.00
11.65
L*9C*C20
FC/PC/UC60C
21
1445
40.5
31.6
13.00
11.50
L*9C*D20
FC/MC/PC/UC60D
24
1435
40.5
31.6
13.00
11.60
L*9C*D20
HC60
24
1435
40.5
31.6
13.00
11.60
THRD48S41S1
L*(8,L)C*C20
FC/MC62D
24
1670
47.0
35.3
13.00
11.60
L*9C*C20
FC/MC62D
24
1605
47.0
35.3
13.00
11.50
L*9C*D20
FC/MC62D
24
1595
47.0
35.3
13.00
11.40
THRD60S41S1
L*(8,L)C*C20
FC/MC62D
24
1750
54.0
42.5
13.00
11.00
L*9C*C20
FC/MC62D
24
1650
53.0
41.0
13.00
11.00
L*9C*D20
FC/MC62D
24
1615
53.5
41.5
13.00
11.00
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Variable speed furnaces have B.O.D (Blower on Delay) standard.