445073-LTG-A-0109
18
Johnson Controls Unitary Products
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO
THRD24S41S1
EVAPORATOR COIL MODEL NO
F6FP24
AIR TEMP.
ENTERING
OUTDOOR UNIT
AIR TEMP.
ENTERING
INDOOR COIL
ID CFM
600
800
1000
MBTUH
KW
C.O.P.
MBTUH
KW
C.O.P.
MBTUH
KW
C.O.P.
60
60
27.6
1.8
4.3
28.9
1.7
4.6
30.2
1.6
4.9
70
25.9
1.9
3.8
27.2
1.8
4.1
28.5
1.7
4.4
80
24.1
2.0
3.4
25.5
1.9
3.7
26.8
1.8
3.9
47
60
22.7
1.6
3.8
23.8
1.6
4.0
24.9
1.5
4.2
70
21.4
1.7
3.5
22.4
1.7
3.6
23.4
1.6
3.8
80
20.1
1.8
3.1
21.0
1.7
3.3
21.8
1.7
3.4
40
60
20.3
1.6
3.6
21.0
1.5
3.7
21.8
1.5
3.8
70
19.1
1.6
3.2
19.8
1.6
3.4
20.5
1.6
3.5
80
17.9
1.7
2.9
18.5
1.6
3.0
19.1
1.6
3.1
30
60
15.9
1.4
3.0
17.0
1.4
3.2
18.1
1.4
3.4
70
15.4
1.5
2.8
16.2
1.5
2.9
17.0
1.5
3.0
80
14.9
1.6
2.6
15.4
1.5
2.7
15.8
1.5
2.7
17
60
12.8
1.3
2.6
13.5
1.3
2.7
14.2
1.3
2.8
70
11.7
1.3
2.4
12.2
1.3
2.4
12.7
1.3
2.5
80
10.6
1.3
2.1
10.9
1.3
2.2
11.2
1.3
2.2
10
60
1.0
1.7
0.2
6.2
1.5
1.1
11.4
1.2
2.4
70
5.0
1.5
0.9
7.6
1.4
1.5
10.2
1.2
2.1
80
9.0
1.2
1.9
9.1
1.2
1.9
9.1
1.2
1.9
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler
Coil
MBH
KW
COP
MV12B
FC/MC24B
1.00
1.00
1.00
MV12B
FC/MC30B
1.00
1.00
1.00
AV24
–
1.00
1.00
1.00
Variable Speed
Furnace
Coil
MBH
KW
COP
L*(8,L)C*A12
FC/MC/PC/UC24A
1.00
1.00
1.00
L*(8,L)C*B12
FC/MC/PC/UC24B
1.00
1.00
1.00
L*9C*B12
FC/MC/PC/UC24B
1.00
1.00
1.00
L*(8,L)C*A12
FC/MC/PC/UC30A
1.00
1.00
1.00
L*(8,L)C*B12
FC/MC/PC/UC30B
1.00
1.00
1.00
L*9C*B12
FC/MC/PC/UC30B
1.00
1.00
1.00
L*(8,L)C*A12
HC30
1.00
1.00
1.00