Luxaire FHP 240 Installation Manual Download Page 18

035-18200-000-B-1102

18

Unitary Products Group

FIGURE 18: UNIT DIMENSIONS FHP180

27-5/8

2-3/8

2-3/16

56-3/8

1

2-3/16

31-5/8

62-5/8

FILTER ACCESS PANEL
Filters can be removed
through either side of
the unit.

COIL
SECT.

BLOWER
SECTION

32-3/8

6

7-1/4

16-1/2

7/8

BLOWER MOTOR AND DRIVE ACCESS PANEL
(Always on the wiring connection side of unit)
Located on opposite side ONLY when the blower
section has been rotated 180  from position shown.

1-23/32" KNOCKOUT
Remove only when Electric
Heat Accessory is used.

7/8" KNOCKOUT FOR POWER WIRING
Do not remove this knockout when the unit is equipped with an Electric
Heat Accessory.  Refer to detail of the Heater Accessory for power
wiring access opening.

7/8" KNOCKOUT FOR
CONTROL WIRING

ALTERNATE
2-5/8" KNOCKOUT*

*Refer to INSTALLING REFRIGERANT MAINS in installation instruction
when piping through the opposite side of the unit.

AIR

IN

12-7/8

2-7/8

2-7/8

Ø 1-3/8

ALL DIMENSIONS ARE IN INCHES THEY
ARE SUBJECT TO CHANGE WITHOUT 
NOTICE.  CERTIFIED DIMENSIONS WILL
BE PROVIDED UPON REQUEST.

ACCESSORIES

Electric Heaters - Add 14-1/4 inches to unit height when
using 10, 20, 30 or 50 kW heater.
Plenum - Add 27 inches to overall unit height when used.
Base Add 24 inches to overall unit height when used.

5-11/16

8-1/2

9-1/2

4

Ø 2"

Ø 2"

2-1/8

18-7/8

5-1/2

AIR

OUT

5-7/8

19-3/8

21-7/8

60-3/4

TABLE 10: FHP180 MINIMUM CLEARANCES

Side with RETURN AIR opening

24”

Side with SUPPLY AIR opening

24”

1

Side with PIPING CONNECTIONS

61”

2

Side with access to both POWER & CONTROL WIRING

-

3

Bottom

-

4

1.

Overall dimensions of the unit will vary if an electric
heater, a supply air plenum or a base is used.

2.

This dimension is required for removal of the coil. Only
26” is required for normal service.

3.

If the coil has to be removed, this dimension is required
to loosen screws that secure the coil to the unit frame.
This dimension will also be required for blower motor
access if the piping connections are made on the oppo-
site side of the unit

4.

Allow enough clearance to trap the condensate drain
line.

Summary of Contents for FHP 240

Page 1: ...NING Notes are intended to clarify or make the installation easier Cautions are given to prevent equipment damage Warnings are given to alert installer that personal injury and or equipment dam age ma...

Page 2: ...AIR GRILLE FHP240 10 Fig Pg 8 BASE ACCESSORY FHP180 10 9 BASE ACCESSORY FHP240 10 10 SUPPLY AIR PLENUM FHP180 10 11 SUPPLY AIR PLENUM KNOCKOUTS FHP180 10 12 SUPPLY AIR PLENUM FHP240 11 13 RECOMMENDED...

Page 3: ...n on the installation and operation of the matching outdoor unit refer to part no 035 17399 000 Installer should pay particular attention to the words NOTE CAUTION and WARNING Notes are intended to cl...

Page 4: ...RE 4 and make sure that its weight will be distrib uted equally LOCATION These indoor units are not designed for outdoor instal lation They must be located within the building struc ture either inside...

Page 5: ...re feet 16 7 24 1 Unit Weight lbs Shipping 425 830 Operating 435 720 Accessory Operating Weight Lbs Motor Drive 3 HP 90 90 5 HP 120 Electric Heat 10 KW 63 20 KW 66 126 30 KW 71 129 40 KW 132 50 KW 80...

Page 6: ...LBS SUSP N POINT W 3 HP MOTOR W HEATER ACCESS W PLENUM ACCESS W HEATER PLENUM ACCESS A 95 95 85 85 B 120 120 100 100 C 95 115 165 185 D 115 140 185 205 Total Wt 425 470 535 575 3 1 1 2 COIL SECTION BL...

Page 7: ...LOWER SECTION HEATING COIL SUSPENSION CHANNEL 43 3 4 5 A B C D E F 55 HANGER RODS FIELD SUPPLIED ELECTRIC HEAT ACCESS 40lbs each TABLE 4 FHP240 UNIT SUSPENSION WEIGHTS LBS SUSPENSION POINT W 5HP MOTOR...

Page 8: ...r discharge as shown in illustration a the blower module can be repositioned in the field as shown in illustrations b and c for maximum flexibility The Supply Air Plenum Return Air Grille and Base acc...

Page 9: ...for wire sizes up through 1 AWG Remove the knockout ring and add a 1 1 2 inch conduit fitting to the 1 31 32 inch hole for wire sizes up through 0 AWG 50 KW Add a 1 1 4 inch conduit fitting to the 1...

Page 10: ...FIGURE 10 SUPPLY AIR PLENUM FHP 1801 1 Electric Heaters are NOT UL approved for installation within a SUPPLY AIR PLENUM FIGURE 11 SUPPLY AIR PLENUM KNOCKOUTS FHP180 1 9 7 8 1 6 1 8 2 1 2 5 5 3 4 6 0 3...

Page 11: ...r glass insulation and a sealing material such as permagum should be packed around refrigerant lines where they penetrate a wall to reduce vibration and to retain some flexibiltiy Support all refriger...

Page 12: ...or mance in Table 6 Knowing the required blower RPM and the blower motor HP the settings turns open for the supply air motor pulley can be determined from Table 6 Each motor pulley has 1 A threaded ba...

Page 13: ...il under field conditions would be inaccurate To assure a dry coil the heat pump system should be de activated while the test is being run 4 Knowing the pressure drop across a dry coil the actual CFM...

Page 14: ...esistance based on a wet evaporator coil clean filters and unit tested in horizontal configuration 2 Available static pressure in IWG to overcome the resistance of the duct system and any accessories...

Page 15: ...TABLE 8 SUPPLY AIR PERFORMANCE FHP2401 RPM CFM 6400 7200 8000 8800 9600 ESP2 BHP3 kW4 ESP2 BHP3 kW4 ESP2 BHP3 kW4 ESP2 BHP3 kW4 ESP2 BHP3 kW4 600 0 15 1 49 1 42 650 0 31 1 71 1 63 0 14 2 00 1 90 700...

Page 16: ...153 2 175 2 0 AWG 1073 150 460 3 60 57 6 76 6 80 4 AWG 1347 100 FHP240A 5 20 KW 208 3 60 41 6 68 0 70 4 AWG 186 100 230 3 60 46 2 70 6 80 4 AWG 251 100 460 3 60 23 1 35 3 40 8 AWG 381 60 30 KW 208 3...

Page 17: ...r motor are permanently lubricated and should not require any additional lubricant BELTS Maintain belt tension to extend belt life Replace the signs of failure begin to appear FIGURE 17 TYPICAL FIELD...

Page 18: ...DIMENSIONS ARE IN INCHES THEY ARE SUBJECT TO CHANGE WITHOUT NOTICE CERTIFIED DIMENSIONS WILL BE PROVIDED UPON REQUEST ACCESSORIES Electric Heaters Add 14 1 4 inches to unit height when using 10 20 30...

Page 19: ...1 2 2 7 8 8 1 2 8 1 2 ALL DIMENSIONS ARE IN INCHES THEY ARE SUBJECT TO CHANGE WITHOUT NOTICE CERTIFIED DIMENSIONS WILL BE PROVIDED UPON REQUEST ACCESSORIES Electric Heaters Add 14 1 4 to unit height w...

Page 20: ...change without notice Printed in U S A 035 18200 000 B 1102 Copyright by Unitary Products Group 2002 All rights reserved Supersedes 035 18200 000 Rev A 0401 Unitary 5005 Norman Products York OK Group...